Hang Zhao

Hang Zhao

Auto-generated profile, based on publicly available information

Hang Zhao

National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics , Mianyang, Sichuan 621900

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2019 in Matter and Radiation at Extremes
Verified
Journal Article
Open access
PDF file
HZHang Zhao
Hang Zhao
ZLZhichao Li
Zhichao Li
DYDong Yang
Dong Yang
XLXin Li
Xin Li
YCYaohua Chen
Yaohua Chen
YDYongkun Ding
Yongkun Ding
Optical Thomson scattering (OTS) diagnostics have been continuously developed on a series of large laser facilities for inertial confinement fusion (ICF) research in China. We review recent progress in the use of OTS diagnostics to study the internal plasma conditions of ICF gas-filled hohlraums. We establish the predictive capability for experiments by calculating the time-resolved Thomson scattering spectra based on the 2D radiation-hydrodynamic code LARED, and we explore the fitting method for the measured spectra. A typical experiment with a simplified cylindrical hohlraum is conducted on a 10 kJ-level laser facility, and the plasma evolution around the laser entrance hole is analyzed. The dynamic effects of the blast wave from the covering membrane and the convergence of shocks on the hohlraum axis are observed, and the experimental results agree well with those of simulations. Another typical experiment with an octahedral spherical hohlraum is conducted on a 100 kJ-level laser facility, and the plasma evolution at the hohlraum center is analyzed. A discrepancy appears between experiment and simulation as the electron temperature rises, indicating the occurrence of nonlocal thermal conduction.

28 July 2023 in Matter and Radiation at Extremes
Verified
Journal Article
Open access
PDF file
ZLZhichao Li
Zhichao Li
ZLZhanjun Liu
Zhanjun Liu
TGTao Gong
Tao Gong
WZWenshuai Zhang
Wenshuai Zhang
TXTao Xu
Tao Xu
AHAnd He
And He
The first laser–plasma interaction experiment using lasers of eight beams grouped into one octad has been conducted on the Shenguang Octopus facility. Although each beam intensity is below its individual threshold for stimulated Brillouin backscattering (SBS), collective behaviors are excited to enhance the octad SBS. In particular, when two-color/cone lasers with wavelength separation 0.3 nm are used, the backward SBS reflectivities show novel behavior in which beams of longer wavelength achieve higher SBS gain. This property of SBS can be attributed to the rotation of the wave vectors of common ion acoustic waves due to the competition of detunings between geometrical angle and wavelength separation. This mechanism is confirmed using massively parallel supercomputer simulations with the three-dimensional laser–plasma interaction code LAP3D.

1 September 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HZHang Zhao
Hang Zhao
ZLZhichao Li
Zhichao Li
DYDong Yang
Dong Yang
XJXiaohua Jiang
Xiaohua Jiang
YLYonggang Liu
Yonggang Liu
YDYongkun Ding
Yongkun Ding
An ultraviolet Thomson-scattering system has been designed and implemented on the Shenguang-III laser facility, a 48-beam, 3ω (351 nm), 180 kJ-level laser driver for high energy density physics and inertial confinement fusion researches. The 4ω (263.3 nm) probe beam of the Thomson-scattering system is injected from the north pole (top) of the target chamber, with an assistant beam-pointing monitor to achieve high pointing accuracy. The Thomson-scattered light is collected by a double-Cassegrain optical transmission system, which provides an achromatic image over a wide wavelength range of 200–800 nm. A novel on-line alignment method is developed and applied to the diagnostic system, ensuring a volumetric positioning accuracy of ∼30 μm for the scattering volume. An online calibration is also conducted to provide the wavelength benchmark and the spectral resolution of the system. This Thomson-scattering system has been tested in a complicated experimental environment with gas-filled hohlraums, and a high-quality ion feature of the scattered light has been obtained.

2 January 2024 in Matter and Radiation at Extremes
Verified
Journal Article
Open access
PDF file
CCChaoxin Chen
Chaoxin Chen
TGTao Gong
Tao Gong
ZLZhichao Li
Zhichao Li
LHLiang Hao
Liang Hao
YLYonggang Liu
Yonggang Liu
DYDong Yang
Dong Yang
In an experiment performed on the Shenguang-III prototype laser facility, collective Thomson scattering (TS) is used to study the spatial growth of stimulated Brillouin scattering (SBS) in a gas-filled hohlraum by detecting the SBS-driven ion acoustic wave. High-quality time-resolved SBS and TS spectra are obtained simultaneously in the experiment, and these are analyzed by a steady-state code based on the ray-tracing model. The analysis indicates that ion–ion collisions may play an important role in suppressing SBS growth in the Au plasma; as a result, the SBS excited in the filled gas region is dominant. In the early phase of the laser pulse, SBS originates primarily from the high-density plasma at the edges of the interaction beam channel, which is piled up by the heating of the interaction beam. Throughout the duration of the laser pulse, the presence of the TS probe beam might mitigate SBS by perturbing the density distribution around the region overlapping with the interaction beam.

22 January 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
WTWei-Qiang Tan
Wei-Qiang Tan
YLYao-Yuan Liu
Yao-Yuan Liu
XLXin-Yan Li
Xin-Yan Li
PYPeng Yuan
Peng Yuan
HZHang Zhao
Hang Zhao
JZJian Zheng
Jian Zheng
In this article, we present experiments measuring the electron density of a blown-off aluminum plasma created by a 2 ω (532 nm) laser using dual-angle Thomson scattering diagnosis. By fitting two ion-acoustic-wave feature spectra collected from two angles simultaneously, in a typical shot, the electron density obtained 400 μ m in front of the target as given by Thomson scattering diagnosis was ( 5.9 ± 0.6 ) × 10 18 cm − 3 , which is 35% higher than the average result of ( 4.4 ± 0.7 ) × 10 18 cm − 3 as measured by digital holography diagnosis. The distribution of the electron density along the laser axis from 400 μ m to 700 μ m as given by dual-angle Thomson scattering was broadly consistent with that obtained from digital holography diagnosis. At a location of 250 μ m in front of the target, a unique set of plasma parameters cannot be obtained by dual-angle Thomson scattering diagnosis. This may be a result of the steep density gradient visible in the hologram in this region. Dual-angle Thomson scattering diagnosis can provide a good estimation of the electron density in plasma parameter regimes similar to those in these experiments, in which the scattering parameter α < 2 . This technique may be useful for small laser facilities that cannot afford a second probe laser with a different wavelength and for measuring electron density with 4 ω Thomson scattering on large laser facilities. This article presents several factors that need to be considered when employing this method.

1 June 2021 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
GXGang Xiong
Gang Xiong
JZJiyan Zhang
Jiyan Zhang
XCXingsen Che
Xingsen Che
BQBo Qing
Bo Qing
ZZZhiyu Zhang
Zhiyu Zhang
JYJiamin Yang
Jiamin Yang
Great efforts have been made to create a bright K-shell source using the thin metal cylindrical cavities in the past few decades. Several metal materials such as titanium (Ti), iron, and so on have been tested for high x-ray conversion efficiency mainly at the OMEGA and NIF laser facilities. Recently, x-ray sources in Ti K-shell transition energy range were investigated at the Shenguang-III prototype laser facility with ∼5 kJ laser energy. The experiments were aimed to reproduce the previous ones at OMEGA, but with an extraordinarily small volume of cylindrical cavity and detailed characterizations of the x-ray source. The cavities were 800 μm inner diameter, 800 μm length, and 30 μm thick plastic tubes supporting 1 μm thick Ti. Seven laser beams were focused to 200 μm diameter. The combination of the small cavity volume and the focused laser spots is intended to improve the electron temperature with limited laser energy since the electron temperature is a key issue for high x-ray conversion efficiency. Thomson scattering was adopted to experimentally probe the electron temperatures at special time and space zones as well as the average temperature obtained from the Ti K-shell spectrum. The evolutions of the electron temperature and density are predicted by the radiation hydrodynamic simulation. A top view and two photon energy bands of x-ray source images provide a way to directly observe the plasma movement toward the cavity axis and distinguish the different emission mechanisms between the Ti K-shell and lower energy x rays. Six Higher-energy x-ray detectors located at different angles were used to record the Ti K-shell x-ray emission and demonstrate its isotropic feature. The characteristics of the x-ray radiate intensity including the time evolution, the angular distribution, and the total yields for both the photon energy regions above and below 4 keV are compared between the cavity and planar targets. Obviously, different behaviors were found between the two photon energy regions and the two types of targets. The x-ray conversion efficiency of the Ti cylinder was determined to be ∼ 4 % and ∼ 21 % in 4 π sr in the Ti K-shell (4–7 keV) and <4 keV range, respectively. The Ti K-shell conversion efficiency obtained in the present experiments is between the ones driven by 13.5 and 4.5 kJ laser energy at OMEGA.