Daniel-Ralph Hermann

Daniel-Ralph Hermann

Auto-generated profile, based on publicly available information

Daniel-Ralph Hermann

Department of Optics, Faculty of Science Palacky University Olomouc Olomouc Czech Republic

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2022 in Analytical Chemistry
Verified
Journal Article
Open access
DHDaniel R. Hermann
Daniel R. Hermann
GRGeorg Ramer
Georg Ramer
MKMarkus Kitzler-Zeiler
Markus Kitzler-Zeiler
IAInstitute of Chemical Technologies and Analytics
Institute of Chemical Technologies and Analytics
Vibrational circular dichroism (VCD) constitutes a powerful technique, enabling the determination of the absolute configuration of molecules without the need for specialized reagents. While delivering critical information, VCD signals commonly are several orders of magnitude weaker than classical absorbance signals, which so far necessitated long measurement times to achieve acceptable signal-to-noise ratios (SNRs) in VCD experiments. We present here an improved setup for the measurement of VCD in the range between 5.6 and 6.5 μm. Employing an external cavity quantum cascade laser (EC-QCL) as a high-power light source, we collected spectra with competitive noise levels in less than 5 min. The basis for this improvement was a balanced detection module combined with an optical path catered to VCD measurements. With the stabilization provided by the two-detector setup, noise originating from the laser source could be suppressed effectively. Noise level improvement up to a factor of 4 compared to the classical single detector EC-QCL-VCD could be reported. Compared to commercial Fourier transform infrared (FT-IR) instruments, the presented setup offers measurement time reductions of a factor of at least 6, with comparable noise levels. The applicability of the setup for qualitative and quantitative VCDs was proven. With the comparatively high temporal resolution provided, the monitoring of optically active processes will be possible in future applications.

4 June 2025 in Journal of Raman Spectroscopy
Verified
Journal Article
Closed access
DLDavid Lilek
David Lilek
DZDaniel Zimmermann
Daniel Zimmermann
LSLukas Steininger
Lukas Steininger
MMMaurizio Musso
Maurizio Musso
BWBodo Wilts
Bodo Wilts
KPKaterina Prohaska
Katerina Prohaska

2 July 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
DHDaniel-Ralph Hermann
Daniel-Ralph Hermann
DLDavid Lilek
David Lilek
CDChristina Daffert
Christina Daffert
IFInes Fritz
Ines Fritz
SWSimone Weinberger
Simone Weinberger
KPKaterina Prohaska
Katerina Prohaska
The production of polyhydroxybutyrate (PHB) by autotrophic fermentation of cyanobacteria has received increasing interest in the light of carbon emission reducing process strategies. Biotechnological approaches are in development to optimize the yield of PHB, including adapted cultivation media, characterized by a limitation of key nutrients: cyanobacteria accumulate PHB as energy storage molecules under limited growth conditions. Since there is an increasing demand for fast, simple and reliable analytics, we report the establishment of surface enhanced Raman spectroscopy (SERS) as a suitable monitoring tool for up scaled PHB production processes. Both, pure Ag-colloids mixed with bacterial culture, and in situ prepared colloids (Ag-Synechocystis), generated on the cell surface directly, were successfully applied and evaluated for this purpose. SERS measurements with in situ prepared Ag-colloids improved the reproducibility of Raman signals from 54.8% to 93.9%. The measurement time could be reduced significantly, completing our secondary goal. The quality of classically and in situ prepared Ag-colloids was monitored by zeta potential measurements and scanning electron microscopy (SEM) respectively. For data interpretation and statistical model-building an in house written code in the open source software RStudio was implemented. It was applied for the differentiation of PHB producers at the cellular level, revealing heterogeneities within sample groups regarding the PHB amount accumulated. The results obtained using the statistical model were validated as well and were complementary to the reference HPLC analysis. Therefore, a fast and reliable identification in situ SERS tool for the selection of the most promising cyanobacterial PHB production was established.

22 November 2024 in Analytical Chemistry
Verified
Journal Article
Open access
DHDaniel-Ralph Hermann
Daniel-Ralph Hermann
GRGeorg Ramer
Georg Ramer
IAInstitute of Chemical Technologies and Analytics
Institute of Chemical Technologies and Analytics
Proteins are characterized by their complex levels of structures, which in turn define their function. Understanding and evaluating these structures is therefore crucial to illuminating biological processes. One of the possible analytical methods is vibrational circular dichroism (VCD), which expands the structural sensitivity of classical infrared (IR) absorbance spectroscopy by the chiral sensitivity of circular dichroism. While this technique is powerful, it is plagued by low signal intensities and long measurement times. Here we present an optical setup leveraging the high brilliance of a quantum cascade laser to measure proteins in D2O at a path length of 204 μm. It was compared to classical Fourier-transform infrared spectroscopy (FT-IR) in terms of noise levels and in its applicability to secondary structure elucidation of proteins. Protein concentrations as low as 2 mg/mL were accessible by the laser-based system at a measurement time of 1 h. Further increase of the time resolution was possible by adapting the emission to cover only the amide I' band. This allowed for the collection of spectral data at a measurement time of 5 min without a loss of performance. With this high time resolution, we are confident that dynamic processes of protein can now be monitored by VCD, increasing our understanding of these reactions.

17 October 2023 in Applied Spectroscopy
Verified
Journal Article
Closed access
DHDaniel-Ralph Hermann
Daniel-Ralph Hermann
GRGeorg Ramer
Georg Ramer
LRLisa Riedlsperger
Lisa Riedlsperger
IAInstitute of Chemical Technologies and Analytics
Institute of Chemical Technologies and Analytics
Recently, high-throughput quantum cascade laser-based vibrational circular dichroism (QCL-VCD) technology has reduced the measurement time for high-quality vibrational circular dichroism spectra from hours to a few minutes. This study evaluates QCL-VCD for chiral monitoring using flow-through measurement of a changing sample in a circulating loop. A balanced detection QCL-VCD system was applied to the enantiomeric pair R/S-1,1′-bi-2-naphthol in solution. Different mixtures of the two components were used to simulate a racemization process, collecting spectral data at a time resolution of 6 min, and over three concentration levels. The goal of this experimental setup was to evaluate QCL-VCD in terms of both molar and enantiomeric excess (EE) sensitivity at a time resolution relevant to chiral monitoring in chemical processes. Subsequent chemometric evaluation by partial least squares regression revealed a cross-validated prediction accuracy of 2.8% EE with a robust prediction also for the test data set (error = 3.5% EE). In addition, the data set was also treated with the least absolute shrinkage and selection operator (LASSO), which also achieved a robust prediction. Due to the operating principle of LASSO, the obtained coefficients constituted a few discrete spectral frequencies, which represent the most variance. This information can be used in the future for dedicated QCL-based instrument design, gaining a higher time resolution without sacrificing predictive capabilities.