Kiyoshi Saito

Kiyoshi Saito

Auto-generated profile, based on publicly available information

Kiyoshi Saito

Department of Applied Mechanics and Aerospace Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2024 in Physiology & Behavior
Verified
Journal Article
Open access
HWHironori Watanabe
Hironori Watanabe
TSTaisuke Sugi
Taisuke Sugi
KSKiyoshi Saito
Kiyoshi Saito
KNKei Nagashima
Kei Nagashima
Thermal comfort in an office impacts physical health, stress, and productivity. Humidity affects thermal comfort; however, the underlying mechanism remains unclear. This study assessed the influence of humidity on body temperature, thermal comfort, stress, and their relationship in working individuals. Thirteen participants performed three sets of 20-min calculation tasks followed by a 10-min rest in 26 °C or 33 °C with relative humidity (RH) of 30 % or 60 %. Core body temperature (Tcore), mean skin surface temperature (Tskin), and electrocardiogram were continuously recorded. Subjective thermal sensations and comfort were assessed with visual analog scales. Stress level was estimated based on α-amylase activity and immunoglobulin A level in saliva and heart rate variability. Mean Tskin and Tcore elevated at 33 °C with 60 % RH, where warm sensation and thermal discomfort also increased. Heart rate variability reflecting parasympathetic nerve activity decreased. There was a negative linear relationship between weighted body temperature and thermal comfort. However, thermal discomfort was augmented at a given weighted body temperature at 60 % RH. Thus, under indoor working conditions, high humidity may augment thermal discomfort and become a stress factor. Increases in Tskin and Tcore are involved in the mechanism, alongside other factors.

6 August 2018 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
NGNiccolo Giannetti
Niccolo Giannetti
RVRichard Jayson Varela
Richard Jayson Varela
HAHifni Mukhtar Ariyadi
Hifni Mukhtar Ariyadi
SYSeiichi Yamaguchi
Seiichi Yamaguchi
KSKiyoshi Saito
Kiyoshi Saito
HNHiroshi Nakayama
Hiroshi Nakayama
This study involves exploring a new design of an internally cooled/heated desiccant contactor by using a new ionic liquid (IL) solution as the sorptive solution. In order to optimize its operative performance, a semitheoretical model based on the principle of minimum energy is developed to predict the film rupture and wetting ability of the IL solution over a comprehensive range of IL mass fraction and flow rates. A first experimental validation of the fundamental equations of the theoretical model is presented and used as a reference to minimize deviations between predicted results and measured data by calibrating dedicated characteristic coefficients. The noteworthy quantitative and qualitative agreement in the whole range of IL mass fractions and flow rates is promising for contributing to the design of optimized system configurations and control strategies.

5 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MKMooJoong KIM
MooJoong KIM
KKKanta Komeda
Kanta Komeda
JJJONGSOO JEONG
JONGSOO JEONG
MOMizuki Oinuma
Mizuki Oinuma
TSTetsuya Sato
Tetsuya Sato
KSKiyoshi Saito
Kiyoshi Saito
In this study, a technique that uses a capacitance sensor with an asymmetric electrode to measure the void fraction of a refrigerant was developed. It is known that the void fraction and flow pattern affect the measured capacitance. Therefore, the relationship between the void fraction and capacitance is not linear; hence, a calibration method for obtaining accurate measurements is necessary. A calibration method was designed in this study based on repeated capacitance measurements and the bimodal temporal distribution to calibrate the atypical and repetitive flow patterns of slug flow and its transition to the intermittent flow regime. The calibration method also considers the weighted-average relation for the gradual transition of the intermittent to annular flow pattern according to the change from low to high quality. The proposed method was experimentally analyzed under the conditions of R32 refrigerant, a tube inner diameter of 7.1 mm, saturation temperature of 25 °C, mass flux of 100–400 kg m−2 s−1, and vapor quality of 0.025–0.900, and it was validated using a quick-closing valve (QCV) system under identical conditions. A relative error of 2.99% was obtained for the entire system, indicating good agreement between the proposed and QCV-based methods.

18 April 2025 in Machines
Verified
Journal Article
Open access
PDF file
RSRoopesh Chowdary Sureddi
Roopesh Chowdary Sureddi
Liang LiLiang Li
Liang Li
Hongwei WuHongwei Wu
Hongwei Wu
NGNiccolo Giannetti
Niccolo Giannetti
KSKiyoshi Saito
Kiyoshi Saito
DRDavid W. A. Rees
David W. A. Rees
Heating and cooling are the main concerns across a wide range of sectors, including residential buildings, industrial facilities, transportation and commercial enterprises. This being the case, a continuous rise in the cost of energy demands more effective ways to conserve energy. Heat pump (HP) systems provide the one of the best possible solutions to this problem as they offer an economical and energy-efficient system. In this review, HP systems are overviewed as energy-efficient and cost-effective solutions, focusing on their characteristic properties but also on enhancements, novel techniques and the use of heat exchangers (HXs), and microchannel heat exchangers (MCHEs) in these systems, as well as their development in recent years and their limitations. The main factors contributing to variations in the performance of HP systems are temperature and humidity in the ambient atmosphere. The present study is expected to support numerical and experimental performance analysis, and design miniaturisation via MCHEs. Unique designs or manufacturing techniques in MCHEs; various configurations in HP systems, depending on their load and environmental conditions; various nanofluids; and a comparison of nanofluids with different base metals are presented and discussed. Comparisons between various MCHEs and their respective limitations provide evidence-based guidelines for technology selection and designs for optimised operation at given environmental and load conditions.

2 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKTomihiro Kinjo
Tomihiro Kinjo
YSYuichi Sei
Yuichi Sei
NGNiccolo Giannetti
Niccolo Giannetti
KSKiyoshi Saito
Kiyoshi Saito
Koji EnokiKoji Enoki
Koji Enoki
The prediction of the heat transfer coefficient commonly relies on the development of new empirical prediction equations when operating conditions and refrigerants change from the existing equations. Creating new prediction equations is expensive and time-consuming; therefore, recent attention has been given to machine learning approaches. However, machine learning requires a large amount of data, and insufficient data can result in inadequate accuracy and applicability. This study showed that using mini-channel data as highly relevant data for the micro-fin heat transfer coefficient yields high prediction accuracy, even when the experimental dataset of interest is limited. In the proposed method, we added dimensionless numbers assumed to significantly influence heat transfer coefficients calculated from experimental data to the training dataset. This allowed efficient learning of the characteristics of thin liquid films present in mini-channels and micro-fins. By combining distinctive physical mechanisms related to heat transfer coefficients with DNN/GPR/Fine-tuning, the proposed method can predict 96.7% of the data points within ±30% deviation. In addition, it has been confirmed that the dryout quality and post-dryout heat transfer coefficients were predicted with high accuracy. Additionally, we utilized visualization techniques to investigate the contents of the black-box machine learning models.

9 August 2018 in Entropy
Verified
Journal Article
Open access
PDF file
NGNiccolo Giannetti
Niccolo Giannetti
SYSeiichi Yamaguchi
Seiichi Yamaguchi
Andrea RocchettiAndrea Rocchetti
Andrea Rocchetti
KSKiyoshi Saito
Kiyoshi Saito
A new general thermodynamic mapping of desiccant systems’ performance is conducted to estimate the potentiality and determine the proper application field of the technology. This targets certain room conditions and given outdoor temperature and humidity prior to the selection of the specific desiccant material and technical details of the system configuration. This allows the choice of the operative state of the system to be independent from the limitations of the specific design and working fluid. An expression of the entropy balance suitable for describing the operability of a desiccant system at steady state is obtained by applying a control volume approach, defining sensible and latent effectiveness parameters, and assuming ideal gas behaviour of the air-vapour mixture. This formulation, together with mass and energy balances, is used to conduct a general screening of the system performance. The theoretical advantage and limitation of desiccant dehumidification air conditioning, maximum efficiency for given conditions constraints, least irreversible configuration for a given operative target, and characteristics of the system for a target efficiency can be obtained from this thermodynamic mapping. Once the thermo-physical properties and the thermodynamic equilibrium relationship of the liquid desiccant mixture or solid coating material are known, this method can be applied to a specific technical case to select the most appropriate working medium and guide the specific system design to achieve the target performance.