Pietro Bonazzi

Pietro Bonazzi

Auto-generated profile, based on publicly available information

Pietro Bonazzi

Department of Information Technology and Electrical Engineering, ETH Zurich, Swiss Federal Institute of Technology in Zurich, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

5 October 2024
Verified
Conference Paper
Open access
SBSizhen Bian
Sizhen Bian
PKPixi Kang
Pixi Kang
JMJulian Moosmann
Julian Moosmann
LMLiu Mengxi
Liu Mengxi
PBPietro Bonazzi
Pietro Bonazzi
Michele MagnoMichele Magno
Michele Magno
Electroencephalogram (EEG)-based Brain-Computer Interfaces (BCIs) have garnered significant interest across various domains, including rehabilitation and robotics. Despite advancements in neural network-based EEG decoding, maintaining performance across diverse user populations remains challenging due to feature distribution drift. This paper presents an effective approach to address this challenge by implementing a lightweight and efficient on-device learning engine for wearable motor imagery recognition. The proposed approach, applied to the well-established EEGNet architecture, enables real-time and accurate adaptation to EEG signals from unregistered users. Leveraging the newly released low-power parallel RISC-V-based processor, GAP9 from Greeenwaves, and the Physionet EEG Motor Imagery dataset, we demonstrate a remarkable accuracy gain of up to 7.31% with respect to the baseline with a memory footprint of 15.6 KByte. Furthermore, by optimizing the input stream, we achieve enhanced real-time performance without compromising inference accuracy. Our tailored approach exhibits inference time of 14.9 ms and 0.76 mJ per single inference and 20 us and 0.83 uJ per single update during online training. These findings highlight the feasibility of our method for edge EEG devices as well as other battery-powered wearable AI systems suffering from subject-dependant feature distribution drift.

18 August 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CBChiara Botrugno
Chiara Botrugno
KDKanika Dheman
Kanika Dheman
PBPietro Bonazzi
Pietro Bonazzi
Francesco Dell'olioFrancesco Dell'olio
Francesco Dell'olio
Michele MagnoMichele Magno
Michele Magno
Non-invasive vital signs monitoring, especially blood pressure (BP), is crucial for evaluating overall health and identifying early indicators of medical issues. Photoplethysmography (PPG) is a non-invasive technique increasingly adopted in vital sign monitoring, as it allows for the continuous and precise measurement of cardiac-related signals. This technology is sensitive to fluctuations in blood volume within blood vessels, enabling real-time tracking of each heartbeat and identification of any irregularities. This study investigates the effectiveness of machine learning models for predicting arterial pressure based solely on PPG signals, utilizing a novel dataset and multi-wavelength sensor technology that captures data from four distinct wavelengths: infrared, red, green, and blue. The participant pool consisted of 88 individuals, with each measurement lasting 30 seconds at a sampling rate of 100 Hz. After a dedicated phase of signal preprocessing, three methodologies were assessed: a multi-layer perceptron (MLP) utilizing 84 features per subject, a dimensionality reduction strategy through Principal Component Analysis (PCA), and a Convolutional Neural Network (CNN) architecture. The CNN approach showcased impressive performance metrics, with results aligning with the standards set by the Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS). Additionally, to further enhance accuracy, a Support Vector Regression (SVR) correction algorithm was applied, as a post-processing phase, addressing discrepancies in measurements related to age, thereby improving the reliability of the arterial pressure predictions and reaching errors of 1.36 ± 2.98 mmHg and 1.52 ± 2.67 mmHg for systolic and diastolic blood pressure respectively. Compared with recent cuff-less BP estimators that rely on single-wavelength PPG or PTT features and typically report MAE values of 3–5 mmHg, the proposed multi-wavelength hybrid CNN-SVR shrinks the error by more than 60% (MAE = 1.84/1.98 mmHg for SBP/DBP, Table II), while still meeting AAMI and BHS grade A/B requirements. This establishes, to the best of our knowledge, the first sub-2 mmHg, AAMI-compliant result obtained with a commodity optical front-end and no calibration.