Xiaojun Lyu

Xiaojun Lyu

Auto-generated profile, based on publicly available information

Xiaojun Lyu

Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
XLXiaojun Lyu
Xiaojun Lyu
Vahid HamedpourVahid Hamedpour
Vahid Hamedpour
YSYui Sasaki
Yui Sasaki
ZZZhoujie Zhang
Zhoujie Zhang
Tsuyoshi MinamiTsuyoshi Minami
Tsuyoshi Minami

22 February 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
LDLinlin Du
Linlin Du
YLYijia Lao
Yijia Lao
YSYui Sasaki
Yui Sasaki
XLXiaojun Lyu
Xiaojun Lyu
PGPeng Gao
Peng Gao
YLYuanli Liu
Yuanli Liu
We herein report the quantitative detection of biogenic amines using a gold nanoparticle-based colorimetric chemosensor array for food analysis. The gold nanoparticles are functionalized with carboxylate derivatives, which capture target amines through hydrogen bonds and electrostatic interactions. The simultaneous discrimination of 10 amine derivatives was achieved by a linear discriminant analysis with a 100% correct classification based on the multi-colorimetric response pattern of structural differences. Furthermore, a real sample analysis for raw fish (i.e., tuna) demonstrated highly accurate determination of histamine concentrations by a support vector machine, the result of which was matched with high-performance liquid chromatography. Most importantly, the chemosensor array succeeded in detecting the time-dependent concentration change of histamine in the raw fish, meaning that the decomposition of the fish could be monitored by the colorimetric changes. Hence, the proposed chemosensor array combined with pattern recognition techniques can be a user-friendly analytical method for food freshness monitoring.


16 February 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
KOKohei Ohshiro
Kohei Ohshiro
YSYui Sasaki
Yui Sasaki
QZQi Zhou
Qi Zhou
XLXiaojun Lyu
Xiaojun Lyu
YYYusuke Yamanashi
Yusuke Yamanashi
Tsuyoshi MinamiTsuyoshi Minami
Tsuyoshi Minami
An extended-gate-type organic field-effect transistor immunosensor has successfully detected oxytocin at ppt levels in human saliva with high recovery rates (96–102%).

25 November 2020 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
YSYui Sasaki
Yui Sasaki
XLXiaojun Lyu
Xiaojun Lyu
RKRiku Kubota
Riku Kubota
STShin-Ya Takizawa
Shin-Ya Takizawa
Tsuyoshi MinamiTsuyoshi Minami
Tsuyoshi Minami

7 February 2024 in RSC Advances
Verified
Journal Article
Open access
PDF file
YSYui Sasaki
Yui Sasaki
XLXiaojun Lyu
Xiaojun Lyu
TKTakayuki Kawashima
Takayuki Kawashima
YZYijing Zhang
Yijing Zhang
KOKohei Ohshiro
Kohei Ohshiro
Tsuyoshi MinamiTsuyoshi Minami
Tsuyoshi Minami
π-Conjugated polymers such as polythiophene provide intramolecular wire effects upon analyte capture, which contribute to sensitive detection in chemical sensing. However, inherent aggregation-induced quenching causes difficulty in fluorescent chemical sensing in the solid state. Herein, we propose a solid-state fluorescent chemosensor array device made of a paper substrate (PCSAD) for the qualitative and quantitative detection of metal ions. A polythiophene derivative modified by dipicolylamine moieties (1poly), which shows optical changes upon the addition of target metal ions (i.e., Cu2+, Cd2+, Ni2+, Co2+, Pb2+, Zn2+, and Hg2+), was highly dispersed on the paper substrate using office apparatus. In this regard, morphological observation of the PCSAD after printing of 1poly suggested the contribution of the fiber structures of the paper substrate to the homogeneous dispersion of 1poly ink to suppress aggregation-induced quenching. The optical changes in the PCSAD upon the addition of metal ions was rapidly recorded using a smartphone, which was further applied to imaging analysis and pattern recognition techniques for high-throughput sensing. Indeed, the printed PCSAD embedded with 1poly achieved the accurate detection of metal ions at ppm levels contained in river water. The limit of detection of the PCSAD-based sensing system using a smartphone (48 ppb for Cu2+ ions) is comparable to that of a solution-based sensing system using a stationary spectrophotometer (16 ppb for Cu2+ ions). Therefore, the methodology based on a combination of a paper-based sensor array and a π-conjugated polymer will be a promising approach for solid-state fluorescent chemosensors.