Kaj Lampio

Kaj Lampio

Auto-generated profile, based on publicly available information

Kaj Lampio

Tampere University of Technology, P.O. Box 589, Tampere FI-33101, Finland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2017 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
KLK. Lampio
K. Lampio
RKR. Karvinen
R. Karvinen

1 December 2017 in Microelectronics Reliability
Verified
Journal Article
Closed access
KLKaj Lampio
Kaj Lampio
RKReijo Karvinen
Reijo Karvinen

1 June 2015 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
MLMatti Lindstedt
Matti Lindstedt
KLKaj Lampio
Kaj Lampio
RKReijo Karvinen
Reijo Karvinen

9 December 2019 in Heat Transfer Engineering
Verified
Journal Article
Closed access
NNNiko Pietari Niemelä
Niko Pietari Niemelä
AMAntti Mikkonen
Antti Mikkonen
KLKaj Lampio
Kaj Lampio
JKJukka Konttinen
Jukka Konttinen
Inline tube configuration is used in various heat exchangers, such as power plant superheaters. The important design parameters are the longitudinal and transverse spacing between the tubes, as they determine the flow and heat transfer characteristics of the tube bank. In superheaters, the transverse tube spacing is often relatively large in order to avoid clogging of the flow passages due to deposition of particulate matter. To design and optimize superheaters is a challenging task, especially because of the complicated vortex-shedding phenomenon. This also complicates the computational fluid dynamics (CFD) modeling, because unsteady simulation approach is required. This paper discusses about various factors that affect the accuracy of prediction of heat transfer and flow characteristics of inline tube banks with large transverse spacing. A suitable CFD model is constructed by comparing different boundary conditions, domain dimensions, domain size, and turbulence models in unsteady simulations. The numerically obtained Nusselt numbers are evaluated against available heat transfer correlations. The correlation of Gnielinski is recommended for tube banks with large transverse spacing, as it agrees within ±13% with the numerically obtained values. The guidelines presented in the paper can serve as reference for future simulations of unsteady flow phenomena.

1 September 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
KLK Lampio
K Lampio
RKR Karvinen
R Karvinen
Fins and fin arrays with constant temperature at the fin base have known solutions for natural convection. However, in practical applications, no simple solution exists for maximum temperature of heat sink with many heat dissipating components located at the base plate. A calculation model is introduced here to solve this practical problem without time consuming CFD modelling of fluid flow and heat transfer. Solutions with the new model are compared with some simple analytical and CFD solutions to prove that the results are accurate enough for practical applications. Seminal here is that results are obtained many orders of magnitude faster than with CFD. This much shorter calculation time scale makes the model well suited for multi-objective optimization in, e.g., simultaneous minimization of heat sink maximum temperature, size, and mass. An optimization case is presented in which heat sink mass and size are significantly reduced over those of the original reference heat sink.

21 November 2016
Verified
Conference Paper
Closed access
KLKaj Lampio
Kaj Lampio
RKReijo Karvinen
Reijo Karvinen
A method is presented to determine the temperature field of an electronics cooling heat sink. The method is based on calculation of heat conduction in a solid numerically with the finite volume method and on solving fluid convection from analytical equations. The model is suitable for forced and natural convection heat sinks, and it uses solutions of a parallel plate channel for the friction factor and the convection Nusselt number. The validity of the method is verified by comparing its results to measured data and to CFD calculations. After verification, two practical multi-objective optimization examples are given. The first one, an industrial application, is a forced convection heat sink composed of nine heat generating components at the base plate. Then, natural convection optimization is performed on a reference array with two components. In both cases, mass is minimized, the other criterion being the maximum temperature for forced convection case, and the heat sink outer volume for natural convection case.