Travis R. Weiner

Travis R. Weiner

Auto-generated profile, based on publicly available information

Travis R. Weiner

Columbia University Irving Medical Center

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2024 in Arthroplasty Today
Verified
Journal Article
Open access
TWTravis R. Weiner
Travis R. Weiner
CWCatelyn A. Woelfle
Catelyn A. Woelfle
WXWinnie Xu
Winnie Xu
DYDuke G. Yim
Duke G. Yim
RSRoshan P. Shah
Roshan P. Shah
HCH. John Cooper
H. John Cooper
Initial stability of cementless stems is important to minimize the risk of subsidence, pain, and periprosthetic fracture after total hip arthroplasty (THA). Collared stems improve initial component stability when contacting the femoral calcar. Direct contact is not always achieved, and collared stem performance has not been studied in this context. We hypothesized that collared stems achieving direct contact would demonstrate reduced subsidence. A single-surgeon retrospective study of 482 consecutive primary THAs implanted between February 2020 and May 2023 using collared cementless stems was performed. The 2 cohorts included stems with initial collar-calcar contact vs stems without. Subsidence was evaluated by comparing intraoperative fluoroscopy to postoperative 8-week radiographs. Binary logistic regression identified independent risk factors for subsidence. Chi-square tests were used for categorical variables and t-tests for continuous variables. Of stems, 63.9% achieved initial collar-calcar contact, while 36.1% did not. The rate (1.3% vs 19.0%; P < .001) and magnitude (0.02 mm, range 0-3 mm vs 0.35 mm, range 0-3 mm; P < .001) of subsidence were significantly higher among stems without initial contact. Stems without initial collar-calcar contact (P < .001) and male gender (P = .007) were independent risk factors for subsidence. Two patients with initial contact had nondisplaced calcar cracks and <3 mm of subsidence at 4 weeks, which healed with protected weight-bearing. Stem survivorship was 100% in both groups, with all achieving osteointegration and none needing revision. Excellent performance of collared cementless stems was observed at 8 weeks after primary THA. Initial collar-calcar contact lowered the risk and magnitude of minor subsidence but did not affect survivorship or fracture risk. Level III.

26 January 2024 in Orthopedic Reviews
Verified
Journal Article
Open access
PDF file
TWTravis R Weiner
Travis R Weiner
DEDany B El-Najjar
Dany B El-Najjar
CHCarl L Herndon
Carl L Herndon
CWCody C Wyles
Cody C Wyles
HCH John Cooper
H John Cooper
While the role and benefit of perioperative intravenous (IV) antibiotics in patients undergoing total joint arthroplasty (TJA) is well-established, oral antibiotic use in TJA remains a controversial topic with wide variations in practice patterns. With this review, we aimed to better educate the orthopedic surgeon on when and how oral antibiotics may be used most effectively in TJA patients, and to identify gaps in the literature that could be clarified with targeted research. Extended oral antibiotic prophylaxis (EOAP) use in high-risk primary, aseptic revision, and exchange TJA for infection may be useful in decreasing periprosthetic joint infection (PJI) rates. When prescribing oral antibiotics either as EOAP or for draining wounds, patient factors, type of surgery, and type of infectious organisms should be considered in order to optimally prevent and treat PJI. It is important to maintain antibiotic stewardship by administering the proper duration, dose, and type of antibiotics and by consulting infectious disease when necessary.

9 January 2023 in Journal of Orthopaedic Experience & Innovation
Verified
Journal Article
Open access
PDF file
JFJeremy S Frederick
Jeremy S Frederick
TWTravis R Weiner
Travis R Weiner
ANAlexander L Neuwirth
Alexander L Neuwirth
RSRoshan P Shah
Roshan P Shah
JGJeffrey A Geller
Jeffrey A Geller
HCH. John Cooper
H. John Cooper
Background: Database studies demonstrate a strong association between use of direct oral anticoagulant (DOAC) medications and stiffness following total knee arthroplasty (TKA). The goal of this study was to evaluate whether the risk of stiffness in patients receiving a DOAC was affected by concomitant use or avoidance of a selective COX-2 inhibitor, when compared to a control group of patients receiving aspirin. Methods: Consecutive primary TKA’s performed at a single institution between January 2014 - September 2019 were retrospectively reviewed. During this period, a risk-stratification algorithm for prophylaxis against venous thromboembolism (VTE) was used, with DOACs selected for patients at elevated VTE risk and aspirin for the remainder. Patients who required manipulation under anesthesia (MUA) within six months of index TKA were identified. Arc of motion (AOM) data at 6-weeks, 3-months, and 1-year was collected. Patients were divided into 3 groups based on postoperative medications prescribed: (a) Aspirin, (b) DOAC alone, and (c) DOAC + NSAID. Categorical variables were analyzed using Fisher’s Exact Tests and Pearson’s Chi-Square, while continuous variables were analyzed using Student’s T-test. Multivariate logistic regression was used to assess MUA risk while controlling for demographic differences. Results: Forty patients underwent MUA from a population of 1,358 TKAs (2.9%). There was a significantly increased risk of MUA in patients where DOACs were used and concomitant NSAIDs were avoided when compared to the control group of patients receiving aspirin (5.4% vs 2.7%, OR 3.17; p = 0.029). This increased risk was not present when DOACs were used concomitantly with NSAIDs (3.1% vs 2.7%, OR 1.30; p = 0.573). In addition, less consistent AOM was achieved at 1-year postoperatively in the DOAC alone group compared to the control group of patients receiving aspirin (p=0.034). Conclusions: Compared to aspirin anticoagulation, patients receiving DOACs without concomitant NSAIDs were more likely to develop postoperative stiffness requiring MUA and achieved less predictable AOM. The addition of selective COX-2 inhibitors may mitigate some risk of stiffness following primary TKA when anticoagulation with DOACs is necessary.

18 February 2026 in Journal of Orthopaedic Experience & Innovation
Verified
Journal Article
Open access
TWTravis R Weiner
Travis R Weiner
CWCatelyn A Woelfle
Catelyn A Woelfle
MEMouhanad M El-Othmani
Mouhanad M El-Othmani
ANAlexander L Neuwirth
Alexander L Neuwirth
JGJeffrey A Geller
Jeffrey A Geller
HCH John Cooper
H John Cooper
Introduction: Anterior knee pain remains a commonly reported complaint following total knee arthroplasty (TKA) and has been shown to correlate to the patella as a source. While robotic knee systems have been shown to improve femoral and tibial component accuracy, the impact of robotics on patella tracking and tilt has not been adequately studied. Therefore, we sought to compare patellar tilt in robotic and conventional TKA. Methods: We retrospectively reviewed 602 consecutive primary TKAs by a single surgeon over a 4-year period. The population was divided into two cohorts: robotic vs. conventional. Patellar tilt was measured using merchant view radiographs. Chi-square tests were used to examine for differences between categorical variables and t-tests for continuous variables. Binary logistic regression was used to control for differences between cohorts. Results: A total of 260 robotic knees and 311 conventional knees were included. There were no differences in demographics between groups. A binary logistic regression showed no significant association between decreasing patellar tilt and a lack of patellar resurfacing (p = 0.217, Odds Ratio = 1.045, 95% CI = 0.974-1.121). Using the absolute value, the mean patellar tilt in the robotic cohort was 1.96° compared to 2.89° of tilt in the conventional cohort (p = 0.0001). The percentage of outliers where the patellar tilt exceeded 3 degrees from neutral was significantly higher among conventional cohort (34% vs 20%, p=0.00018). WOMAC Pain scores were significantly improved in the robotic vs nonrobotic cohort (16.6 vs 15.0, p < 0.001). Conclusion: Robotic TKA leads to an improvement in patellar tilt, with a smaller percentage of outliers, compared to conventional TKA. These findings could partially explain the improved pain with robotic TKA.

19 May 2023 in The Journal of Hip Surgery
Verified
Journal Article
Closed access
PDF file
TWTravis R. Weiner
Travis R. Weiner
ANAlexander L. Neuwirth
Alexander L. Neuwirth
JGJeffrey A. Geller
Jeffrey A. Geller
RSRoshan P. Shah
Roshan P. Shah
THThomas R. Hickernell
Thomas R. Hickernell
HCH. John Cooper
H. John Cooper
Conventional incision orientation for direct anterior approach (DAA) total hip arthroplasty (THA) is longitudinal, paralleling fibers of the tensor fascia latae. Alternatively, a “bikini” incision can be oriented along Langer's lines. We sought to determine if there were any differences in surgical site complications (SSCs), mechanical complications, or reoperation between longitudinal and bikini DAA. We retrospectively reviewed 420 consecutive primary DAA THA by a single surgeon over a 2-year period. The surgeon was experienced with both incision orientations. Complications were recorded by chart review. Chi-square tests were used to examine for differences between categorical variables and t-tests for continuous variables. Longitudinal incisions were used in 320 patients (76.2%) while bikini incisions were used in 100 patients (23.8%). Women were significantly more likely to have a bikini incision (39.1% vs. 5.8%; p < 0.00001). Across the entire cohort, patients undergoing THA through either longitudinal or bikini incision had comparable rates of SSCs (4.7% vs. 5.0%; p = 0.90). With longitudinal incisions, SSCs were more likely to occur in obese patients compared with nonobese patients (8.3% vs. 3.1%; p = 0.04). With bikini incisions, there was no difference in the rate of SSCs between obese and nonobese patients (4.0% vs. 5.3%; p = 0.79). There were no differences in mechanical complications or rates of reoperation (0.3% vs. 0.0%; p = 0.58). Both longitudinal and bikini incisions are safe and effective ways to perform the DAA for primary THA, with no differences in rates of SSCs, mechanical complications, or reoperation. For obese patients in this series, the bikini incision was associated with a lower rate of SSCs but requires future study due to dissimilar study groups.

21 July 2023 in Journal of Orthopaedic Experience & Innovation
Verified
Journal Article
Open access
PDF file
TWTravis R Weiner
Travis R Weiner
SBSarah Barringer
Sarah Barringer
LSLaura Silverio
Laura Silverio
ALAkshay Lakra
Akshay Lakra
JGJeffrey A Geller
Jeffrey A Geller
RSRoshan P Shah
Roshan P Shah
# Introduction Recall of auditory and physical sensations during hip and knee arthroplasty surgery is inadequately studied. We investigated rates of sensory recall, impact on satisfaction, and risk factors. # Methods We surveyed 164 consecutive patients after primary or revision arthroplasty about sensory recall and its impact on satisfaction (improved, worsened, or no effect), without exclusions. Three surgeons and 25 anesthesiologists in an academic university hospital setting provided care. Demographic data (age, gender, BMI, comorbidities, ASA class), type of anesthesia, intravenous fentanyl and midazolam doses, pre-operative diagnosis, type of surgery, anesthesia duration, and surgery time (morning vs afternoon case) were analyzed. Pearson’s correlation coefficient was calculated for each variable. A binary logistic regression model was used to identify risk factors for sensory recall. # Results 147 patients (89.6%) received spinal anesthesia. No patients receiving general anesthesia had recall. Twenty-three patients (14.0% of the total, 15.6% of neuraxial anesthesia patients) had sensory recall after surgery: 19 (11.6%) auditory, 2 (1.2%) physical, and 2 (1.2%) both. There was a correlation between spinal anesthesia and sensory recall, r = 0.163, p = 0.037. On logistic regression, decreasing age (p=0.032, 95% CI, 0.894–0.995) and less midazolam (p = 0.009, 95% CI, 0.283–0.832) were significant risk factors for sensory recall. Seventeen (73.9%) reported no impact on satisfaction (14 auditory, 2 physical, 1 both), while two (8.7%) reported worse satisfaction (1 auditory, 1 both) and four (17.4%) reported improved satisfaction (all auditory). # Conclusion We found a 14.0% rate of sensory recall. Spinal anesthesia, decreasing age, and lower benzodiazepine administration were associated with sensory recall. Sensory recall has a minimal effect on patient satisfaction, although some were still affected. Although we focused on instrument sounds, our high rate of sensory recall serves as a reminder to also be mindful of conversations in the operating room. # Level of Evidence Level II