Kevin J. Chung

Kevin J. Chung

Auto-generated profile, based on publicly available information

Kevin J. Chung

Department of Radiology, University of California Davis Health, Sacramento, CA, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
Qiu WuQiu Wu
Qiu Wu
HKHulin Kuang
Hulin Kuang
JNJ. Nair
J. Nair
ZAZ. Assis
Z. Assis
MNM. Najm
M. Najm
BMB.K. Menon
B.K. Menon
BACKGROUND AND PURPOSE: Thrombus characteristics identified on non-contrast CT (NCCT) are potentially associated with recanalization with intravenous (IV) alteplase in patients with acute ischemic stroke (AIS). Our aim was to determine the best radiomics-based features of thrombus on NCCT and CT angiography associated with recanalization with IV alteplase in AIS patients and proximal intracranial thrombi. MATERIALS AND METHODS: With a nested case-control design, 67 patients with ICA/M1 MCA segment thrombus treated with IV alteplase were included in this analysis. Three hundred twenty-six radiomics features were extracted from each thrombus on both NCCT and CTA images. Linear discriminative analysis was applied to select features most strongly associated with early recanalization with IV alteplase. These features were then used to train a linear support vector machine classifier. Ten times 5-fold cross-validation was used to evaluate the accuracy of the trained classifier and the stability of the selected features. RESULTS: Receiver operating characteristic curves showed that thrombus radiomics features are predictive of early recanalization with IV alteplase. The combination of radiomics features from NCCT, CTA, and radiomics changes is best associated with early recanalization with IV alteplase (area under the curve = 0.85) and was significantly better than any single feature such as thrombus length (P < .001), volume (P < .001), and permeability as measured by mean attenuation increase (P < .001), maximum attenuation in CTA (P < .001), maximum attenuation increase (P < .001), and assessment of residual flow grade (P < .001). CONCLUSIONS: Thrombus radiomics features derived from NCCT and CTA are more predictive of recanalization with IV alteplase in patients with acute ischemic stroke with proximal occlusion than previously known thrombus imaging features such as length, volume, and permeability.

30 March 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
KCKevin J. Chung
Kevin J. Chung
YAYasser Gaber Abdelhafez
Yasser Gaber Abdelhafez
BSBenjamin A. Spencer
Benjamin A. Spencer
TJTerry Jones
Terry Jones
QTQuyen Tran
Quyen Tran
GWGuobao Wang
Guobao Wang
Neuroimaging of blood-brain barrier permeability has been instrumental in identifying its broad involvement in neurological and systemic diseases. However, current methods evaluate the blood-brain barrier mainly as a structural barrier. Here we developed a non-invasive positron emission tomography method in humans to measure the blood-brain barrier permeability of molecular radiotracers that cross the blood-brain barrier through its molecule-specific transport mechanism. Our method uses high-temporal resolution dynamic imaging and kinetic modeling for multiparametric imaging and quantification of the blood-brain barrier permeability-surface area product of molecular radiotracers. We show, in humans, our method can resolve blood-brain barrier permeability across three radiotracers and demonstrate its utility in studying brain aging and brain-body interactions in metabolic dysfunction-associated steatotic liver inflammation. Our method opens new directions to effectively study the molecular permeability of the human blood-brain barrier in vivo using the large catalogue of available molecular positron emission tomography tracers.

30 April 2025 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
KCKevin J. Chung
Kevin J. Chung
ACAbhijit J. Chaudhari
Abhijit J. Chaudhari
LNLorenzo Nardo
Lorenzo Nardo
TJTerry Jones
Terry Jones
MCMoon S. Chen
Moon S. Chen
GWGuobao Wang
Guobao Wang
Past efforts to measure blood flow with the widely available radiotracer 18F-FDG were limited to tissues with high 18F-FDG extraction fraction. In this study, we developed an early dynamic 18F-FDG PET method with high-temporal-resolution (HTR) kinetic modeling to assess total-body blood flow based on deriving the vascular phase of 18F-FDG transit and conducted a pilot comparison study against a 11C-butanol flow-tracer reference. Methods: The first 2 min of dynamic PET scans were reconstructed at HTR (60 × 1 s/frame, 30 × 2 s/frame) to resolve the rapid passage of the radiotracer through blood vessels. In contrast to existing methods that use blood-to-tissue transport rate as a surrogate of blood flow, our method directly estimated blood flow using a distributed kinetic model (adiabatic approximation to tissue homogeneity [AATH] model). To validate our 18F-FDG measurements of blood flow against a reference flow-specific radiotracer, we analyzed total-body dynamic PET images of 6 human participants scanned with both 18F-FDG and 11C-butanol. An additional 34 total-body dynamic 18F-FDG PET images of healthy participants were analyzed for comparison against published blood-flow ranges. Regional blood flow was estimated across the body, and total-body parametric imaging of blood flow was conducted for visual assessment. AATH and standard compartment model fitting was compared using the Akaike information criterion at different temporal resolutions. Results:18F-FDG blood flow was in quantitative agreement with flow measured from 11C-butanol across same-subject regional measurements (Pearson correlation coefficient, 0.955; P < 0.001; linear regression slope and intercept, 0.973 and –0.012, respectively), which was visually corroborated by total-body blood-flow parametric imaging. Our method resolved a wide range of blood-flow values across the body in broad agreement with published ranges (e.g., healthy cohort values of 0.51 ± 0.12 mL/min/cm3 in the cerebral cortex and 2.03 ± 0.64 mL/min/cm3 in the lungs). HTR (1–2 s/frame) was required for AATH modeling. Conclusion: Total-body blood-flow imaging was feasible using early dynamic 18F-FDG PET with HTR kinetic modeling. This method may be combined with standard 18F-FDG PET methods to enable efficient single-tracer multiparametric flow-metabolism imaging, with numerous research and clinical applications in oncology, cardiovascular disease, pain medicine, and neuroscience. Visual Abstract

20 December 2019 in IEEE Signal Processing Letters
Verified
Journal Article
Closed access
KCKevin J. Chung
Kevin J. Chung
RSRoberto Souza
Roberto Souza
RFRichard Frayne
Richard Frayne
Lossy image compression allows for efficient storage and transfer of image data with varying degrees of image degradation. However, lossy compression is not commonly used in medical imaging as the process may irreversibly remove information that defines clinically important image features. The lossy component of JPEG compression is represented as lost precision in the discrete cosine transform (DCT) domain after quantization on 8×8 image blocks and results in degradation of the image. We propose a cross-domain cascade of U-nets called the W-net. This network operates in the DCT domain to restore discarded DCT coefficients that leverages information from adjacent blocks, and the image domain to suppress compression artifacts at the image pixel level. For comparison, we adapted the Automated Transform by Manifold Approximation (AUTOMAP) method for JPEG decompression by learning the dequantization of individual 8×8 DCT coefficient blocks. These results were then transformed to the image domain and processed by a U-net. The deep learning models were able to suppress common compression artifacts at the expense of high spatial frequency detail. Both the W-net and AUTOMAP network structures were quantitatively superior to standard JPEG decompression, with the W-net outperforming AUTOMAP, suggesting that leveraging DCT coefficients from adjacent blocks improves JPEG decompression performance.

29 October 2022 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Closed access
KCKevin J. Chung
Kevin J. Chung
AKAlexander V. Khaw
Alexander V. Khaw
SPSachin K. Pandey
Sachin K. Pandey
DLDonald H. Lee
Donald H. Lee
JMJennifer L. Mandzia
Jennifer L. Mandzia
TLTing-Yim Lee
Ting-Yim Lee

17 December 2019 in International Journal of Stroke
Verified
Journal Article
Closed access
PDF file
KCKevin J Chung
Kevin J Chung
HKHulin Kuang
Hulin Kuang
AFAlyssa Federico
Alyssa Federico
HCHyun Seok Choi
Hyun Seok Choi
LKLinda Kasickova
Linda Kasickova
Qiu WuQiu Wu
Qiu Wu
Manual segmentations of intracranial hemorrhage on non-contrast CT images are the gold-standard in measuring hematoma growth but are prone to rater variability. We demonstrate that a convex optimization-based interactive segmentation approach can accurately and reliably measure intracranial hemorrhage growth. Baseline and 16-h follow-up head non-contrast CT images of 46 subjects presenting with intracranial hemorrhage were selected randomly from the ANNEXA-4 trial imaging database. Three users semi-automatically segmented intracranial hemorrhage to measure hematoma volume for each timepoint using our proposed method. Segmentation accuracy was quantitatively evaluated compared to manual segmentations by using Dice similarity coefficient, Pearson correlation, and Bland–Altman analysis. Intra- and inter-rater reliability of the Dice similarity coefficient and intracranial hemorrhage volumes and volume change were assessed by the intraclass correlation coefficient and minimum detectable change. Among the three users, the mean Dice similarity coefficient, Pearson correlation, and mean difference ranged from 76.79% to 79.76%, 0.970 to 0.980 (p < 0.001), and −1.5 to −0.4 ml, respectively, for all intracranial hemorrhage segmentations. Inter-rater intraclass correlation coefficients between the three users for Dice similarity coefficient and intracranial hemorrhage volume were 0.846 and 0.962, respectively, and the corresponding minimum detectable change was 2.51 ml. Inter-rater intraclass correlation coefficient for intracranial hemorrhage volume change ranged from 0.915 to 0.958 for each user compared to manual measurements, resulting in an minimum detectable change range of 2.14 to 4.26 ml. We spatially and volumetrically validate a novel interactive segmentation method for delineating intracranial hemorrhage on head non-contrast CT images. Good spatial overlap, excellent volume correlation, and good repeatability suggest its usefulness for measuring intracranial hemorrhage volume and volume change on non-contrast CT images.