3 June 2024 in IEEE Transactions on Plasma Science
The insulating vacuum within the ITER Cryostat has a prime purpose to minimize the heat load on the superconducting coil system by gas thermal conductivity. These coils are shielded from thermal radiation by an 80 K helium-cooled silver-coated thermal shield (TS) consisting of $\sim$ 500 panels. Leakage within a cryogenic circuit inside the cryostat is considered to be the prime risk to the ITER project’s mission, as leakage could be disabling to the operation of the magnet systems, be extremely challenging to localize and may be inaccessible for repair. To date, four leaks have been detected and localized within in-cryostat components delivered to ITER. Specifically, three of these leaks have been diagnosed within the TS cooling circuits as having been caused by chlorine-induced stress corrosion cracking (SCC). The technique of high-resolution X-ray computed tomography followed by precision cutting for the generation of macros and micros has been applied to successfully characterize small vacuum leaks for the first time. The techniques were further extended to nonleaking cooling pipes and the onset of SCC was observed in many places, indicating the high probability of the development of many thousands of leaks over time. Such analysis has led to the full replacement/repair program for the TSs before they become overly embedded into ITER. This article summarizes how the helium leakage risk is mitigated and details the detection of extensive SCC on the ITER TSs.
13 March 2025 in Fusion Engineering and Design
1 January 2012 in AIP Conference Proceedings
As part of the vacuum system for the ITER fusion project, a cryogenic viscouscompressor (CVC) is being developed to collect hydrogenic exhaust gases from the toruscryopumps and compress them to a high enough pressure by regeneration for pumping tothe tritium reprocessing facility. Helium impurities that are a byproduct of the fusionreactions pass through the CVC and are pumped by conventional vacuum pumps andexhausted to the atmosphere. Before the development of a full-scale CVC, a representative,small-scale test prototype was designed, fabricated, and tested. With cooling provided bycold helium gas, hydrogen gas was introduced into the central column of the test prototypepump at flow rates between 0.001 g/s and 0.008 g/s. Based on the temperatures and flowrates of the cold helium gas, different percentages of hydrogen gas were frozen to the column surface wall as the hydrogen gas flow rate increased. Results from the measured temperatures and pressures will form a benchmark that will be used to judge future heattransfer enhancements to the prototype CVC and to develop a computational fluid dynamicmodel that will help develop design parameters for the full-scale CVC.
11 March 2026 in IEEE Transactions on Plasma Science
ITER extensively uses cryo-pumping for its large vacuum volumes such as the cryostat (~8500 m3), the torus (~1330 m3), and the neutral beam injectors (~200 m3 each). Designed to meet ITER environment conditions, the eight identical cryopumps for torus and cryostat have been all delivered to ITER this year (NB cyropumps of different design are still under development). Each cryopump has a nominal design pumping speed of 100 m3/s for helium, with an 800 mm all metal isolation valve allowing speed modulation and regeneration during plasma operation. These pumps are the second largest client of the cryoplant after the magnets (25% of the overall heat load), and they are the results of a 20 years development. A test facility has been built in the cryoplant building to allow testing them for the first time in ITER relevant cryogenic conditions and gas loads. This is a key opportunity before final installation to characterize not only pump performances but also cryogenic supply operations. Currently equipped with inert gas injection system, the facility will be upgraded to allow testing with hydrogen and deuterium and to supply additional cryogenic clients such as fueling systems as in the ITER port cell. This article describes the test facility’s main features and the main results achieved from the first test campaigns.