Oyediran K. Owoade

Oyediran K. Owoade

Auto-generated profile, based on publicly available information

Oyediran K. Owoade

Environmental Research Laboratory (ERL), Physics Department , Obafemi Awolowo University , Ile-Ife , Nigeria

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2010 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
FOFelix S. OLISE
Felix S. OLISE
OOOyediran K. Owoade
Oyediran K. Owoade
HOHezekiah B. Olaniyi
Hezekiah B. Olaniyi
EOEusebius I. Obiajunwa
Eusebius I. Obiajunwa

1 August 2006 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
OOOyediran K. Owoade
Oyediran K. Owoade
FOFelix S. Olise
Felix S. Olise
IOImoh B. Obioh
Imoh B. Obioh
HOHezekiah B. Olaniyi
Hezekiah B. Olaniyi
EBEzio Bolzacchini
Ezio Bolzacchini
GPGrazia Perrone
Grazia Perrone

1 September 2017 in Journal of Radiation and Nuclear Applications
Verified
Journal Article
Closed access
FOFelix S. Olise
Felix S. Olise
OOOyediran K. Owoade
Oyediran K. Owoade
SASolomon A. Adekola
Solomon A. Adekola
HOHezekiah B. Olaniyi
Hezekiah B. Olaniyi
CMChristopher B. Mtshali
Christopher B. Mtshali
MMMalik Maaza
Malik Maaza

1 July 2009 in Toxicological & Environmental Chemistry
Verified
Journal Article
Closed access
OOO.K. Owoade
O.K. Owoade
FOFelix S. OLISE
Felix S. OLISE
HOH.B. Olaniyi
H.B. Olaniyi
BEbolzacchini ezio
bolzacchini ezio
Elemental concentrations of air particulates collected by gravimetric method in a scrap iron and steel smelter industry were determined using a combination of four different techniques: total reflection X-ray fluorescence (TXRF), the conventional energy dispersive X-ray fluorescence (EDXRF), the modified (polarized) energy dispersive X-ray fluorescence ED(P)XRF, and the inductively coupled plasma optical emission spectroscopy (ICP-OES) analytical techniques. A number of elements were detected by all the techniques, some by one or two while some are better detected by a particular technique. The ICP-OES and TXRF techniques have low detection limits worth of consideration despite the risk of contamination possible during sample preparation. The techniques are observed to be adequate for analytes above K except for Br and Pb, which are significantly lost during digestion of samples. The Mo-target EDXRF, just like ICP-OES and TXRF, cannot detect elements below K but substitute well for them in the analysis of volatile elements like Br and Pb despite its higher detection limits for the said elements. The Mo-target EDXRF is also observed to be inadequate for rare earth elements with energies close to that of Mo as a result of possible poor resolution of the energy peaks. The ED(P)XRF is more adequate in the analysis of low Z elements as well as volatile ones. Where volatile elements like Cl, Br, and Pb and/or low Z elements are of primary interest, the use of techniques involving no elaborate sample preparation should be considered.