Sanaz Khosravani

Sanaz Khosravani

Auto-generated profile, based on publicly available information

Sanaz Khosravani

School of Kinesiology, University of Minnesota, Minneapolis, MN, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2015 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
LCLeonardo Cappello
Leonardo Cappello
NENaveen Elangovan
Naveen Elangovan
SCSara Contu
Sara Contu
SKSanaz Khosravani
Sanaz Khosravani
JKJã¼Rgen Konczak
Jã¼Rgen Konczak
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
Introduction. Impaired proprioception severely affects the control of gross and fine motor function. However, clinical assessment of proprioceptive deficits and its impact on motor function has been difficult to elucidate. Recent advances in haptic robotic interfaces designed for sensorimotor rehabilitation enabled the use of such devices for the assessment of proprioceptive function. Purpose. This study evaluated the feasibility of a wrist robot system to determine proprioceptive discrimination thresholds for two different DoFs of the wrist. Specifically, we sought to accomplish three aims: first, to establish data validity; second, to show that the system is sensitive to detect small differences in acuity; third, to establish test-retest reliability over repeated testing. Methodology. Eleven healthy adult subjects experienced two passive wrist movements and had to verbally indicate which movement had the larger amplitude. Based on a subject’s response data a psychometric function was fitted and the wrist acuity threshold was established at the 75% correct response level. A subset of five subjects repeated the experimentation three times (T1, T2 and T3) to determine the test-retest reliability. Results. Mean threshold for wrist flexion was 2.15°± 0.43° and 1.52°± 0.36° for abduction. Encoder resolutions were 0.0075° (flexion-extension) and 0.0032° (abduction-adduction). Motor resolutions were 0.2° (flexion-extension) and 0.3° (abduction-adduction). Reliability coefficients were rT2-T1=0.986 and rT3-T2=0.971. Conclusions. We currently lack established norm data on the proprioceptive acuity of the wrist to establish direct validity. However, the magnitude of our reported thresholds are physiological plausible and well in line with available threshold data obtained at the elbow joint. Moreover, system has high resolution and is sensitive enough to detect small differences in acuity. Finally, the system produces reliable data over repeated testing.

29 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKSanaz Khosravani
Sanaz Khosravani
AMArash Mahnan
Arash Mahnan
IYI-Ling Yeh
I-Ling Yeh
JAJoshua E. Aman
Joshua E. Aman
PWPeter J. Watson
Peter J. Watson
JUERGEN KONCZAKJUERGEN KONCZAK
JUERGEN KONCZAK
Spasmodic dysphonia (SD) is an incurable focal dystonia of the larynx that impairs speech and communication. Vibro-tactile stimulation (VTS) alters afferent proprioceptive input to sensorimotor cortex that controls speech. This proof-of-concept study examined the effect of laryngeal VTS on speech quality and cortical activity in 13 SD participants who vocalized the vowel /a/ while receiving VTS for 29 minutes. In response to VTS, 9 participants (69%) exhibited a reduction of voice breaks and/or a meaningful increase insmoothed cepstral peak prominence, an acoustic measure of voice/speech quality. Symptom improvements persisted for 20 minutes past VTS. Application of VTS induced a significant suppression of theta band power over the left somatosensory-motor cortex and a significant rise of gamma rhythm over right somatosensory-motor cortex. Such suppression of theta oscillations is observed in patients with cervical dystonia who apply effective sensory tricks, suggesting that VTS in SD may activate a similar neurophysiological mechanism. Results of this feasibility study indicate that laryngeal VTS modulates neuronal synchronization over sensorimotor cortex, which can induce short-term improvements in voice quality. The effects of long-term VTS and its optimal dosage for treating voice symptoms in SD are still unknown and require further systematic study.

10 September 2019 in Sports Medicine and Health Science
Verified
Journal Article
Open access
IYI-Ling Yeh
I-Ling Yeh
NENaveen Elangovan
Naveen Elangovan
RFRebecca Feczer
Rebecca Feczer
SKSanaz Khosravani
Sanaz Khosravani
AMArash Mahnan
Arash Mahnan
JUERGEN KONCZAKJUERGEN KONCZAK
JUERGEN KONCZAK
High vibration transfer from a tennis racquet to the player may cause discomfort, and is hypothesized to influence performance and the onset of muscle fatigue. This study examined a racquet with a novel vibration damping technology (VDT) designed to mitigate frame vibration. Racquet vibration, post-impact vibration transfer to the player, arm electromyographic activity and tennis performance were compared to a non-VDT racquet. Nineteen young adult, competitive tennis players hit forehands and serves until near exhaustion on two days; using one of the two racquets each day. Tri-axial accelerometers mounted to racquet shaft, hand and forearm recorded vibration behaviour. Surface electromyography recorded activity of five arm muscles. In comparison to the non-VDT racquet, the VDT design showed: 1) A significantly lower mean normalised acceleration signal energy at the racquet during unfatigued play (−40%) and at near exhaustion (−34%), which corresponded to a 20–25% lower signal energy at the hand. 2) Reduced signs of arm muscle fatigue at near exhaustion, which was most pronounced in biceps and wrist extensors. 3) Players hit 11% more forehands and placed 40% more hits in the target area at near exhaustion. Conclusion: VDT effectively reduces racquet vibration. Initial evidence indicates that it may delay muscle fatigue, which was associated with increased ball placement accuracy.

26 February 2020 in Neurorehabilitation and Neural Repair
Verified
Journal Article
Closed access
PDF file
SKSanaz Khosravani
Sanaz Khosravani
JBJeffrey Buchanan
Jeffrey Buchanan
MJMatthew D. Johnson
Matthew D. Johnson
JUERGEN KONCZAKJUERGEN KONCZAK
JUERGEN KONCZAK
Background. Cervical dystonia (CD) is a neurological movement disorder characterized by involuntary contractions of the cervical musculature and is known to be associated with proprioceptive dysfunction in dystonic/nondystonic limbs. Objectives. We examined how neck botulinum neurotoxin (BoNT) injection affects wrist proprioception and the corresponding sensorimotor cortical activity in CD. Method. Wrist position sense acuity of the dominant (right) hand was evaluated in 15 CD and 15 control participants. Acuity measures were a psychophysical position sense discrimination threshold (DT; based on passive joint displacement) and joint position matching error (based on active movement). Cortical activity during the motor preparation period of the active joint position matching was examined using electroencephalography. Results. In their symptomatic state, patients demonstrated a significantly higher wrist proprioceptive DT, indicating an abnormal passive wrist position sense. Yet BoNT injections had no significant effect on this threshold. During active joint position matching, errors were significantly larger in patients, but this difference vanished after the administration of BoNT. Motor preparation of active wrist position matching was associated with a significantly higher rise of β-band (13-30 Hz) power over contralateral somatosensory-motor cortical areas in patients. This excessive cortical activity significantly declined post-BoNT. Conclusion. Wrist proprioceptive perception during passive/active movements is abnormal in CD. An excessive rise of premotor/motor cortical β-oscillations during motor planning is associated with this proprioceptive dysfunction. Neck BoNT injections normalized the cortical processing of proprioceptive information from nonsymptomatic limbs, indicating that local injections may affect the central mechanisms of proprioceptive function in CD.

23 March 2019 in Clinical Neurophysiology
Verified
Journal Article
Closed access
SKSanaz Khosravani
Sanaz Khosravani
AMArash Mahnan
Arash Mahnan
IYI-Ling Yeh
I-Ling Yeh
PWPeter J. Watson
Peter J. Watson
Yang ZhangYang Zhang
Yang Zhang
JUERGEN KONCZAKJUERGEN KONCZAK
JUERGEN KONCZAK

1 December 2011
Verified
Conference Paper
Closed access
SKS. Khosravani
S. Khosravani
NLN. Lahimgarzadeh
N. Lahimgarzadeh
AMA. Maleki
A. Maleki
FES cycling system is introduced as a beneficial rehabilitation method for restoring muscle function in SCI patients. The system is made up of three main parts: a cycling device, a controller and an electrical stimulator. In this paper, a commercial motorized bicycle was augmented with an electrical muscle stimulator and a pedal observation interface. Firstly, a six-channel electrical stimulator was designed and manufactured whose output consists of current pulses (faradic/bursting stimulation pulses) with a wide range of rectangular waveforms (monophasic/biphasic) ranging from 0-150 mA with steps of 0.6 mA and time resolution of 5 μs. The device is capable of receiving position feedback data from the cranks and exchanging data with the computer via serial connection, that is, it is capable of sending the cycling speed to the computer and receiving two groups of commands from the computer: the commands, needed for adjusting the frequency and pulse width of the output signals as well as the commands needed for activating the desired stimulation channel at different time intervals. The main advantages of the device are the high level of output current amplitude, the capability of fine time and amplitude tuning, the vast range of output waveforms, and the use of low cost electronics components in its structure which makes it economically efficient for being used in various FES research studies, specially FES-cycling. Secondly, a commercial motorized bicycle (Viva1) is equipped with a pedal observation interface. The device receives the signal produced by the shaft encoder attached to the motor of the bicycle and uses this data in order to calculate the cycling speed and provide an angular position index which is consequently fed to an electromyography device and helps with the process of determining muscle recruitment pattern in FES-cycling.