Donghua Xiao

Donghua Xiao

Auto-generated profile, based on publicly available information

Donghua Xiao

School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DXDonghua Xiao
Donghua Xiao
Haitao HuHaitao Hu
Haitao Hu
SCSiyi Chen
Siyi Chen
YSYitong Song
Yitong Song
PPPengyu Pan
Pengyu Pan
MMMarta Molinas
Marta Molinas
The accurate dq -frame impedance of three-phase grid is essential in the stability analysis of grid-connected VSC system. However, the conventional measurement methods relying on two separate independent injections extremely slow down the impedance measurement speed, lacking adaptability for the actual dynamic industrial grid. To address this shortcoming, this paper proposes a rapid dq -frame impedance measurement approach for three-phase grid. In this approach, only one injection of wideband harmonics is needed so that the injection times can be reduced to half of the conventional methods and then the measurement time is shortened by half, dramatically enhancing the real-time performance of measurement result. Firstly, an interphase QAM multitone current injection method is proposed, which can excite the first group of desired wideband responses through a single injection. Then, a fictitious disturbance excitation method is introduced to substitute for the second injection of actual disturbance, which can construct the second group of wideband responses by rotation transformation. Afterward, the wideband dq -frame impedance can be calculated with these two groups of response data. The feasibility and effectiveness of the proposed approach are validated by both simulation and experiment results.

11 January 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DXDonghua Xiao
Donghua Xiao
Haitao HuHaitao Hu
Haitao Hu
XYXiangyang Yang
Xiangyang Yang
YSYitong Song
Yitong Song
PPPengyu Pan
Pengyu Pan
ZHZhengyou He
Zhengyou He
Accurate and rapid impedance measurement of high-speed train (HST) is crucial for small-signal stability analysis in the train-network system. Although using wideband disturbance can effectively reduce measurement time, its limited and inflexible spectral controllability will lead to inferior disturbance performance, compromising measurement accuracy, and potentially jeopardizing safety. To address this issue, this article proposes an HST impedance measurement approach based on adaptive multifrequency voltage disturbance. This approach enables precise control of the disturbance frequency band as well as adaptive adjustment of both disturbance frequency resolution and amplitude. First, an odd-even segmented frequency injection strategy is proposed to avoid the HST's frequency overlapping effect interfering with wideband impedance measurement. Then, an adaptive frequency resolution adjustment method is proposed to improve measurement accuracy in the frequency segments with heavy impedance fluctuation. Furthermore, a controllable multifrequency voltage injection device is designed for HST impedance measurement, which can inject desired wideband voltage disturbance whose spectrum energy is congregated at designated multiple frequencies with average amplitude. Particularly, the disturbance amplitude can be reduced automatically by adjusting the regulatory factor of modulated signal when capacitor voltage fluctuation exceeds the threshold, thereby enhancing measurement safety. Finally, the effectiveness of the proposed approach is well validated through real-time hardware-in-the-loop experiment.

25 April 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
YSYitong Song
Yitong Song
DXDonghua Xiao
Donghua Xiao
PPPengyu Pan
Pengyu Pan
HCHaojie Chen
Haojie Chen
Haitao HuHaitao Hu
Haitao Hu
ZHZhengyou He
Zhengyou He
Harmonic resonance and power instability issues plague the operation of the traction power system (TPS). Establishing effective models with the correct parameters is widely accepted for analyzing such problems. However, it is still a challenging task for gaps between models and actual scenes. This article proposes an adaptively intrinsic parameter extraction methodology for TPSs based on wideband impedance measurement. An adaptive equivalent parameter model representing the TPSs is established after determining the impedance characteristics of each frequency region. The sensitivity index to the measuring impedance from different schemes is estimated through test data. Also, the measurement scheme is determined, which only needs to inject twice wideband excitation signal into the system at two connection points and measure three pairs of voltage and current sampling signals. The intrinsic parameters extracted are calculated from the adaptive equivalent model and the wideband impedance measurement results. The proposed method can be added to the existing measurement algorithms. It can provide accurate equivalent parameters and guidance for efficient model building. RTLab-PHIL experimental results show that the proposed method yields good parameter extraction and that it can also adapt to changes for various railway TPSs.

1 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiangyang Yang
Xiangyang Yang
Haitao HuHaitao Hu
Haitao Hu
DXDonghua Xiao
Donghua Xiao
HTHaidong Tao
Haidong Tao
YSYitong Song
Yitong Song
ZHZhengyou He
Zhengyou He
Accurate impedance measurements of the train and traction network are crucial for small-signal stability analysis of railway train-network system (RTNS). Although impedance measurement methods for four-quadrant converters in electric trains based on harmonic voltage disturbance injection have been proposed, few studies have investigated the impact of integrating a harmonic generator on RTNS stability. To address this issue, this paper proposes a wideband harmonic disturbance generator (WHDG) and evaluates its impact on RTNS stability. The WHDG primarily comprises the back-to-back converters-based cascaded H-bridge structure and a wideband coupling transformer. This generator can produce multi-frequency perturbations with uniformly distributed spectrum energy. Subsequently, an accurate output impedance model is established based on the detailed topology and parameters of the WHDG. The model accounts for the impact of the DC impedance of the front-stage rectifier on the post-stage inverter. The close alignment between the modeling and simulation results demonstrates the accuracy of the deduced impedance model. Furthermore, an impedance-matching analysis of the RTNS with integrated WHDG is performed, indicating that the internal impedance of the WHDG weakens the stability of the tested RTNS. Finally, the effectiveness of the proposed WHDG is validated via a hardware-in-the-loop experimental platform, and the impedance-matching analysis results are verified.