Li Feng

Li Feng

Auto-generated profile, based on publicly available information

Li Feng

Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology New York University Grossman School of Medicine New York New York USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2013 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LFLi Feng
Li Feng
RGRobert Grimm
Robert Grimm
KBKai Tobias Block
Kai Tobias Block
HCHersh Chandarana
Hersh Chandarana
SKSungheon Kim
Sungheon Kim
RORicardo Otazo
Ricardo Otazo
Purpose: To develop a fast and flexible free‐breathing dynamic volumetric MRI technique, iterative Golden‐angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden‐angle radial sampling.Methods: Radial k‐space data are acquired continuously using the golden‐angle scheme and sorted into time series by grouping an arbitrary number of consecutive spokes into temporal frames. An iterative reconstruction procedure is then performed on the undersampled time series where joint multicoil sparsity is enforced by applying a total‐variation constraint along the temporal dimension. Required coil‐sensitivity profiles are obtained from the time‐averaged data.Results: iGRASP achieved higher acceleration capability than either parallel imaging or coil‐by‐coil compressed sensing alone. It enabled dynamic volumetric imaging with high spatial and temporal resolution for various clinical applications, including free‐breathing dynamic contrast‐enhanced imaging in the abdomen of both adult and pediatric patients, and in the breast and neck of adult patients.Conclusion: The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707–717, 2014.

25 March 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
LFLi Feng
Li Feng
LALeon Axel
Leon Axel
HCHersh Chandarana
Hersh Chandarana
KBKai Tobias Block
Kai Tobias Block
DSDaniel K. Sodickson
Daniel K. Sodickson
RORicardo Otazo
Ricardo Otazo

16 December 2016 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
LFLi Feng
Li Feng
TBThomas Benkert
Thomas Benkert
KBKai Tobias Block
Kai Tobias Block
DSDaniel K. Sodickson
Daniel K. Sodickson
RORicardo Otazo
Ricardo Otazo
HCHersh Chandarana
Hersh Chandarana

6 August 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LFLi Feng
Li Feng
MSMonvadi B. Srichai
Monvadi B. Srichai
RLRuth P. Lim
Ruth P. Lim
AHAlexis Harrison
Alexis Harrison
WKWilson King
Wilson King
DKDaniel Kim
Daniel Kim
For patients with impaired breath‐hold capacity and/or arrhythmias, real‐time cine MRI may be more clinically useful than breath‐hold cine MRI. However, commercially available real‐time cine MRI methods using parallel imaging typically yield relatively poor spatio‐temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm2) and temporal resolution (∼40 ms), to produce high‐quality real‐time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular function. In this work, we present an eightfold accelerated real‐time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k‐t SPARSE‐SENSE). Compared with reference, breath‐hold cine MRI, our eightfold accelerated real‐time cine MRI produced significantly worse qualitative grades (1–5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both eightfold accelerated real‐time cine and breath‐hold cine MRI yielded comparable left ventricular function measurements, with coefficient of variation <10% for left ventricular volumes. Our proposed eightfold accelerated real‐time cine MRI with k–t SPARSE‐SENSE is a promising modality for rapid imaging of myocardial function. J. Magn. Reson. Imaging 2013.

1 January 2013 in Investigative Radiology
Verified
Journal Article
Closed access
HCHersh Chandarana
Hersh Chandarana
LFLi Feng
Li Feng
TBTobias K. Block
Tobias K. Block
ARAndrew B. Rosenkrantz
Andrew B. Rosenkrantz
RLRuth P. Mbbs Lim
Ruth P. Mbbs Lim
RORicardo Otazo
Ricardo Otazo
Objective The objectives of this study were to develop a new method for free-breathing contrast-enhanced multiphase liver magnetic resonance imaging (MRI) using a combination of compressed sensing, parallel imaging, and radial k-space sampling and to demonstrate the feasibility of this method by performing image quality comparison with breath-hold cartesian T1-weighted (conventional) postcontrast acquisitions in healthy participants. Materials and Methods This Health Insurance Portability and Accountability Act–compliant prospective study received approval from the institutional review board. Eight participants underwent 3 separate contrast-enhanced fat-saturated T1-weighted gradient-echo MRI examinations with matching imaging parameters: conventional breath-hold examination with cartesian k-space sampling volumetric interpolate breath hold examination (BH-VIBE) and free-breathing acquisitions with interleaved angle-bisection and continuous golden-angle radial sampling schemes. Interleaved angle-bisection and golden-angle data from each 100 consecutive spokes were reconstructed using a combination of compressed sensing and parallel imaging (interleaved-angle radial sparse parallel [IARASP] and golden-angle radial sparse parallel [GRASP]) to generate multiple postcontrast phases. Arterial- and venous-phase BH-VIBE, IARASP, and GRASP reconstructions were evaluated by 2 radiologists in a blinded fashion. The readers independently assessed quality of enhancement (QE), overall image quality (IQ), and other parameters of image quality on a 5-point scale, with the highest score indicating the most desirable examination. Mixed model analysis of variance was used to compare each measure of image quality. Results Images of BH-VIBE and GRASP had significantly higher QE and IQ values compared with IARASP for both phases (P < 0.05). The differences in QE between BH-VIBE and GRASP for the arterial and venous phases were not significant (P > 0.05). Although GRASP had lower IQ score compared with BH-VIBE for the arterial (3.9 vs 4.8; P < 0.0001) and venous (4.2 vs 4.8; P = 0.005) phases, GRASP received IQ scores of 3 or more in all participants, which was consistent with acceptable or better diagnostic image quality. Conclusion Contrast-enhanced multiphase liver MRI of diagnostic quality can be performed during free breathing using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling.

9 April 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
LFLi Feng
Li Feng
In recent years, golden‐angle radial sampling has received substantial attention and interest in the magnetic resonance imaging (MRI) community, and it has become a popular sampling trajectory for both research and clinical use. However, although the number of relevant techniques and publications has grown rapidly, there is still a lack of a review paper that provides a comprehensive overview and summary of the basics of golden‐angle rotation, the advantages and challenges/limitations of golden‐angle radial sampling, and recommendations in using different types of golden‐angle radial trajectories for MRI applications. Such a review paper is expected to be helpful both for clinicians who are interested in learning the potential benefits of golden‐angle radial sampling and for MRI physicists who are interested in exploring this research direction. The main purpose of this review paper is thus to present an overview and summary about golden‐angle radial MRI sampling. The review consists of three sections. The first section aims to answer basic questions such as: what is a golden angle; how is the golden angle calculated; why is golden‐angle radial sampling useful, and what are its limitations. The second section aims to review more advanced trajectories of golden‐angle radial sampling, including tiny golden‐angle rotation, stack‐of‐stars golden‐angle radial sampling, and three‐dimensional (3D) kooshball golden‐angle radial sampling. Their respective advantages and limitations and potential solutions to address these limitations are also discussed. Finally, the third section reviews MRI applications that can benefit from golden‐angle radial sampling and provides recommendations to readers who are interested in implementing golden‐angle radial trajectories in their MRI studies.Evidence Level: 5Technical Efficacy: Stage 1