Yunxiao Liu

Yunxiao Liu

Auto-generated profile, based on publicly available information

Yunxiao Liu

Department of Colorectal Surgery, the Second Affiliated Hospital of Harbin Medical University, Harbin, China.

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2023 in International Journal of Surgery
Verified
Journal Article
Open access
YLYunxiao Liu
Yunxiao Liu
YWYuliuming Wang
Yuliuming Wang
CWChunlin Wang
Chunlin Wang
XWXin Wang
Xin Wang
XZXin Zhang
Xin Zhang
GWGuiYu Wang
GuiYu Wang
Background: Robotic surgery has been a revolution for colon cancer (CC) patients, with the increasing availability of different competitive robotic systems, but evidence of relevant oncologic outcomes is indeed scarce. Our goal was to compare the surgical quality and short-term oncologic outcomes of the Kangduo Surgical Robotic System and the da Vinci Si Robotic System in patients with CC. Methods: These are results from a subcohort of a multicenter randomized controlled noninferiority trial performed in three centers in China. Enrolled patients were randomly assigned to undergo surgery using either the KD-SR-01 system (KD group) or the da Vinci Si (DV) robotic system (DV group). Neither investigators nor patients were masked to treatment allocation, but assessment of pathological outcomes was masked to treatment allocation. The primary endpoint was surgical success rate. The secondary endpoints were surgical outcomes, pathologic outcomes, and postoperative outcomes. The study is registered at www.chictr.org.cn (ChiCTR2200063172). Although the long-term follow-up results were not a predefined endpoint for this study, late-stage work is in progress. Results: A total of 58 CC patients were included in this study, 28 in the KD group and 30 in the DV group. All patients were successfully operated without any intermediate open/conventional laparoscopic surgery and the success rate of surgery was 100%. Assessment of equipment docking task load and intraoperative operating sensation score were similar between the two groups. Adverse events and Clavien–Dindo grade II or higher grade complication rates were comparable between the two groups. Device arm docking time, robotic arm operation time, and intraoperative bleeding were not significantly different between the two groups. Similar results were obtained from postoperative pathological outcomes and internal environment indexes. Conclusions: The efficacy and safety of the Kangduo Robotic Surgical System has been proved, operation of the Kangduo Robotic System by experienced surgeons for CC is not less effective than the da Vinci robotic System.

31 August 2025 in Advanced Science
Verified
Journal Article
Open access
YLYunxiao Liu
Yunxiao Liu
LZLiwen Zhang
Liwen Zhang
YCYanfen Cui
Yanfen Cui
WZWeiyuan Zhang
Weiyuan Zhang
HHHanqing Hu
Hanqing Hu
XGXu Guan
Xu Guan
Tumor‐draining lymph nodes (LNs) immune status critically influences cancer progression and treatment response, yet reliable non‐invasive assessment remains clinically unavailable. To address this critical gap, an MRI‐derived LNs morphological and topological structure (LNs‐MTS) model is developed to evaluate the immune status of LNs in rectal cancer (RC). Integrating multicenter imaging, transcriptomic, and immunohistochemical data from 1,156 stage I‐II RC patients, enhanced immune activation in non‐metastatic LNs sized ≥0.5 cm and located ≥5 cm from the primary tumor is discovered. Then two quantitative MRI‐derived imaging features across 7,030 radiologically annotated LNs: total LNs volume (tLNV) and total LNs drainage distance (tLND) is developed, forming the basis of the LNs‐MTS model risk subtypes: high‐risk (HRS), moderate‐risk (MRS), and low‐risk (LRS). Patients in the LRS (characterized by large tLNV and distant tLND) show robust immune cell infiltration in the tumor microenvironment and excellent 5‐year survival, whereas HRS (characterized by small tLNV and near tLND) show stromal dominance and poorer prognosis. Clinically, LNs‐MTS offers a more precise and personalized risk assessment than current guideline‐based risk stratification, potentially sparing stage II‐LRS patients from unnecessary adjuvant treatment while identifying stage I‐HRS individuals for more aggressive treatment, providing valuable insights for personalized treatment strategies in RC management.

8 July 2025 in International Journal of Surgery
Verified
Journal Article
Open access
YLYunxiao Liu
Yunxiao Liu
YWYuliuming Wang
Yuliuming Wang
TMTianyi Ma
Tianyi Ma
WZWeiyuan Zhang
Weiyuan Zhang
HZHao Zhang
Hao Zhang
GWGuiYu Wang
GuiYu Wang
Background: The efficacy and safety of the Kangduo (KD) robotic system in colorectal cancer (CRC) surgery are well established. However, its short-term impact on surgical stress response has not been evaluated. Materials and Methods: This study conducted a post hoc analysis of a previous non-inferiority randomized controlled trial. Patients with stage I–III CRC who underwent robotic-assisted radical CRC surgery between July 2022 and May 2023 were randomized 1:1 to the KD or da Vinci (DV) group. The primary outcomes were changes in systemic stress response markers, including alanine aminotransferase, aspartate aminotransferase, white blood cell count, hemoglobin, neutrophil count, albumin, creatinine, blood urea nitrogen, lymphocyte count, C-reactive protein, prealbumin, and the neutrophil-to-lymphocyte ratio. Results: A total of 101 patients were assessed for eligibility, and then 100 patients were enrolled (KD: n = 50; DV: n = 50). No significant differences in stress response marker trajectories were observed between the groups (all P ≥ 0.05). Subgroup analysis of complication-free patients yielded consistent results. Conclusion: Kangduo robotic-assisted CRC surgery induces systemic stress response changes comparable to those observed with the da Vinci.

12 January 2026 in International Journal of Surgery
Verified
Journal Article
Open access
CWChunlin Wang
Chunlin Wang
YWYuliuming Wang
Yuliuming Wang
HZHao Zhang
Hao Zhang
YLYunxiao Liu
Yunxiao Liu
HJHao Jiang
Hao Jiang
GWGuiyu Wang
Guiyu Wang
Purpose: Although robotic surgery has advanced minimally invasive techniques, its ergonomic limitations pose significant musculoskeletal risks to surgeons. This study evaluated whether the Kangduo SR-01 (KD) open console system mitigates intraoperative ergonomic strain while preserving technical performance during robotic colorectal resection. Methods: This study utilized data from a multicenter randomized controlled non-inferiority trial comparing the efficacy and safety of KD versus Da Vinci (DV) robotic systems in assisting colorectal cancer resection. The assessment framework included ergonomic strain (Borg CR-10 Scale), team coordination (Oxford NOTECHS II), and blinded video-based technical performance analysis [Objective Structured Assessment of Technical Skills (OSATS)]. Results: A total of 100 patients were included in the modified intention-to-treat analysis: 50 in the KD group and 50 in the DV group. Body mass index (BMI) and resection types were comparable between groups. Postural demands were significantly higher for neck and back during DV procedures. Discomfort increased significantly more over time (up to 3 h) in the DV group for both neck [MD (95% c.i.) −0.889 (−1.077, −0.701), P < 0.001] and back [MD (95% c.i.) −0.606 (−0.847, −0.364), P < 0.001]. Notably, both systems achieved equivalent technical proficiency (OSATS total: 29.0 vs. 29.0, P = 0.259) and team coordination (NOTECHS II: 74.0 vs. 73.0, P = 0.120) with comparable short-term outcomes. Conclusions: The Kangduo SR-01 open console system significantly alleviated musculoskeletal strain, particularly in the neck and back, during robotic colorectal surgery while maintaining equivalent technical performance. These findings position open console platforms as a viable solution to ergonomic challenges in robotic surgery without compromising team dynamics or procedural efficiency.

11 September 2025 in Colorectal Disease
Verified
Journal Article
Closed access
YLYunxiao Liu
Yunxiao Liu
XGXu Guan
Xu Guan
QXQing Xu
Qing Xu
TLTaiyuan Li
Taiyuan Li
YZYangchun Zheng
Yangchun Zheng
GWGuiyu Wang
Guiyu Wang

13 June 2025 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
CWChunlin Wang
Chunlin Wang
YWYuliuming Wang
Yuliuming Wang
YLYunxiao Liu
Yunxiao Liu
HZHao Zhang
Hao Zhang
XZXin Zhang
Xin Zhang
GWGuiyu Wang
Guiyu Wang
Robot-assisted natural orifice specimen extraction surgery (NOSES) for sigmoid colon cancer represents an innovative, minimally invasive surgical technique that integrates the benefits of minimally invasive surgery with natural orifice specimen extraction. In this study, a 67-year-old male patient diagnosed with sigmoid colon cancer underwent Kangduo surgical robot-assisted NOSES, with a total operative time of 290 min and an estimated intraoperative blood loss of 50 mL. The procedure involved robotic-assisted radical resection of the sigmoid colon, regional lymphadenectomy, and specimen extraction through a natural orifice. Postoperative histopathological analysis confirmed the absence of residual malignancy in the resected sigmoid colon, while 12 pericolic lymph nodes exhibited reactive hyperplasia. Both the proximal and distal surgical margins were negative for malignancy. The patient had an uneventful recovery and was discharged on postoperative day 7. The precision and flexibility of the robotic system facilitated NOSES by minimizing abdominal wall trauma, reducing postoperative complications, and shortening recovery time. This finding indicates that robot-assisted NOSES is a safe and feasible approach for the surgical treatment of sigmoid colon cancer, though further clinical experience and long-term follow-up are required to comprehensively assess its efficacy.