Aleks Attanasio

Aleks Attanasio

Auto-generated profile, based on publicly available information

Aleks Attanasio

Storm Lab U.K., School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K.

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
PLPeter Lloyd
Peter Lloyd
AHAli Kafash Hoshiar
Ali Kafash Hoshiar
TVTomas da Veiga
Tomas da Veiga
AAAleks Attanasio
Aleks Attanasio
NMNils Marahrens
Nils Marahrens
PVPietro Valdastri
Pietro Valdastri
Soft continuum robots have the potential to revolutionize minimally invasive surgery. The challenges for such robots are ubiquitous; functioning within sensitive, unstructured and convoluted environments which are inconsistent between patients. As such, there exists an open design problem for robots of this genre. Research currently exists relating to the design considerations of on-board actuated soft robots such as fluid and tendon driven manipulators. Magnetically reactive robots, however, exhibit off-board actuation and consequently demonstrate far greater potential for miniaturization and dexterity. In this letter we present a soft, magnetically actuated, slender, shape forming `tentacle-like' robot. To overcome the associated design challenges we also propose a novel design methodology based on a Neural Network trained using Finite Element Simulations. We demonstrate how our design approach generates static, two-dimensional tentacle profiles under homogeneous actuation based on predefined, desired deformations. To demonstrate our learnt approach, we fabricate and actuate candidate tentacles of 2 mm diameter and 42 mm length producing shape profiles within 8% mean absolute percentage error of desired shapes. With this proof of concept, we make the first step towards showing how tentacles with bespoke magnetic profiles may be designed and manufactured to suit specific anatomical constraints.

4 August 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
AAAleks Attanasio
Aleks Attanasio
Bruno ScaglioniBruno Scaglioni
Bruno Scaglioni
MLMatteo Leonetti
Matteo Leonetti
Attilio FrangiAttilio Frangi
Attilio Frangi
WCWilliam Cross
William Cross
PVPietro Valdastri
Pietro Valdastri
In this work, we describe a novel framework for planning and execution of semi-autonomous tissue retraction in robotic minimally invasive surgery. The approach is aimed at autonomously removing flaps of organs or connective tissue from the surgical area, thus exposing the underlying anatomy. Initially, a deep neural network is used to analyse the endoscopic image and detect candidate flaps of tissue that obstruct the scene. Subsequently, a procedural algorithm, aimed at planning and executing the retraction gesture, is developed from extended discussions with clinicians. Experimental validation, carried out on a DaVinci Research Kit, shows an enhancement of the visible background ranging from 151.9% to 235.2%. Another significant contribution of this paper is a dataset, containing 1080 labelled surgical stereo images and the associated depth maps, representing tissue flaps in different scenarios. The work described in this paper is a fundamental step towards the autonomous execution of tissue retraction and the first example based on the simultaneous use of deep learning and procedural algorithms. The same framework could be applied to a wide range of autonomous tasks, such as debridement and placement of laparoscopic clips.

26 January 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
AAAleks Attanasio
Aleks Attanasio
CAChiara Alberti
Chiara Alberti
Bruno ScaglioniBruno Scaglioni
Bruno Scaglioni
NMNils Marahrens
Nils Marahrens
Attilio FrangiAttilio Frangi
Attilio Frangi
PVPietro Valdastri
Pietro Valdastri
In surgical robotics, the ability to achieve high levels of autonomy is often limited by the complexity of the surgical scene. Autonomous interaction with soft tissues requires machines able to examine and understand the endoscopic video streams in real-time and identify the features of interest. In this work, we show the first example of spatio-temporal neural networks, based on the U-Net, aimed at segmenting soft tissues in endoscopic images. The networks, equipped with Long Short-Term Memory and Attention Gate cells, can extract the correlation between consecutive frames in an endoscopic video stream, thus enhancing the segmentation's accuracy with respect to the standard U-Net. Initially, three configurations of the spatio-temporal layers are compared to select the best architecture. Afterwards, the parameters of the network are optimised and finally the results are compared with the standard U-Net. An accuracy of 83.77% ± 2.18% and a precision of 78.42% ± 7.38% are achieved by implementing both Long Short Term Memory (LSTM) convolutional layers and Attention Gate blocks. The results, although originated in the context of surgical tissue retraction, could benefit many autonomous tasks such as ablation, suturing and debridement.