Nara Sousa Rodrigues

Nara Sousa Rodrigues

Auto-generated profile, based on publicly available information

Nara Sousa Rodrigues

Postgraduate Program of Dentistry - Faculty of Pharmacy, Dentistry and Nursing, Federal University of Ceará, Fortaleza, Ceará, Brazil

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Dentistry
Verified
Journal Article
Closed access
LSLidiane Costa de Souza
Lidiane Costa de Souza
NRNara Sousa Rodrigues
Nara Sousa Rodrigues
DCDiana Cunha
Diana Cunha
VFVictor Feitosa
Victor Feitosa
SSSérgio Lima Santiago
Sérgio Lima Santiago
JPJorge Perdigao
Jorge Perdigao

1 May 2020 in Journal of Dentistry
Verified
Journal Article
Closed access
LSLidiane Costa de Souza
Lidiane Costa de Souza
NRNara Sousa Rodrigues
Nara Sousa Rodrigues
DCDiana Cunha
Diana Cunha
VFVictor Feitosa
Victor Feitosa
SSSérgio Lima Santiago
Sérgio Lima Santiago
VSVicente de Paulo Aragão Saboia
Vicente de Paulo Aragão Saboia

25 June 2018 in Materials
Verified
Journal Article
Open access
PDF file
DCDiana Cunha
Diana Cunha
NRNara S. Rodrigues
Nara S. Rodrigues
LSLidiane C. Souza
Lidiane C. Souza
DLDiego Lomonaco
Diego Lomonaco
FRFlávia P. Rodrigues
Flávia P. Rodrigues
VSVicente P. A. Saboia
Vicente P. A. Saboia
This study is aimed at evaluating the effects of triclosan-encapsulated halloysite nanotubes (HNT/TCN) on the physicochemical and microbiological properties of an experimental dental composite. A resin composite doped with HNT/TCN (8% w/w), a control resin composite without nanotubes (HNT/TCN-0%) and a commercial nanofilled resin (CN) were assessed for degree of conversion (DC), flexural strength (FS), flexural modulus (FM), polymerization stress (PS), dynamic thermomechanical (DMA) and thermogravimetric analysis (TGA). The antibacterial properties (M) were also evaluated using a 5-day biofilm assay (CFU/mL). Data was submitted to one-way ANOVA and Tukey tests. There was no significant statistical difference in DC, FM and RU between the tested composites (p > 0.05). The FS and CN values attained with the HNT/TCN composite were higher (p < 0.05) than those obtained with the HNT/TCN-0%. The DMA analysis showed significant differences in the TAN δ (p = 0.006) and Tg (p = 0) between the groups. TGA curves showed significant differences between the groups in terms of degradation (p = 0.046) and weight loss (p = 0.317). The addition of HNT/TCN induced higher PS, although no significant antimicrobial effect was observed (p = 0.977) between the groups for CFUs and (p = 0.557) dry weight. The incorporation of HNT/TCN showed improvements in physicochemical and mechanical properties of resin composites. Such material may represent an alternative choice for therapeutic restorative treatments, although no significance was found in terms of antibacterial properties. However, it is possible that current antibacterial tests, as the one used in this laboratory study, may not be totally appropriate for the evaluation of resin composites, unless accompanied with aging protocols (e.g., thermocycling and load cycling) that allow the release of therapeutic agents incorporated in such materials.

1 March 2018 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
NRNara Sousa Rodrigues
Nara Sousa Rodrigues
LSLidiane Costa de Souza
Lidiane Costa de Souza
VFVictor Feitosa
Victor Feitosa
ALAlessandro Dourado Loguercio
Alessandro Dourado Loguercio
CDCamillo D'Arcangelo
Camillo D'Arcangelo
VSVicente de Paulo Aragão Saboia
Vicente de Paulo Aragão Saboia

1 April 2016 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
LSLidiane Costa de Souza
Lidiane Costa de Souza
NRNara Sousa Rodrigues
Nara Sousa Rodrigues
VFVictor Feitosa
Victor Feitosa
ILIssis Luque-Martínez
Issis Luque-Martínez
ALAlessandro Dourado Loguercio
Alessandro Dourado Loguercio
VSVicente de Paulo Aragão Saboia
Vicente de Paulo Aragão Saboia

3 January 2022 in Brazilian Journal of Oral Sciences
Verified
Journal Article
Open access
PDF file
AMAna Margarida dos Santos Melo
Ana Margarida dos Santos Melo
ARAnne Kaline Claudino Ribeiro
Anne Kaline Claudino Ribeiro
DCDiana Araújo Cunha
Diana Araújo Cunha
NRNara Sousa Rodrigues
Nara Sousa Rodrigues
VSVicente de Paulo Aragão Saboia
Vicente de Paulo Aragão Saboia
IAIsauremi Vieira de Assunção
Isauremi Vieira de Assunção
Aim: To evaluate the impact of a dual-cured adhesive system on the in situ degree of conversion (DC), bond strength (BS) and failure mode (FM) of adhesive interfaces in dentin cavities restored with a bulk-fill resin composite. Methods: 4-mm-deep dentin cavities with a 3.1 C-factor were created in 68 bovine incisors (n = 17 per group). The lightcured (Scotchbond™ Universal) or the dual-cured (Adper™ Scotchbond™ Multi-purpose Plus) adhesive system was applied to the cavities, which were then restored with a bulkfill resin composite (Filtek™ Bulk Fill). In situ DC analysis was performed by means of micro Raman spectroscopy at the top and bottom interfaces. Push-out BS was measured in a universal testing machine after 24-h or 6-month water storage. FM was determined with a stereomicroscope. Data of in situ DC and BS were analyzed by two-way analysis of variance (ANOVA) and Tukey test (p<0.05), while the FM was analyzed descriptively. Results: The groups that received the dual-cured adhesive system showed statistically higher in situ DC and BS than those that received the light-cured adhesive system. Cohesive failure mode was the most frequent in all conditions. Conclusion: In situ DC and BS were influenced by the curing strategies of the adhesive systems with better performance of the dual-cured material.