1 November 2018 in Journal of Craniofacial Surgery
The objectives of this study were to assess the potential of platelet-rich fibrin (PRF) on acceleration of soft tissue healing after tooth extraction and to evaluate its effectiveness in reducing the prevalence of dry socket among smoker patients. Twenty smoker male patients aged (18–72) years with multiple teeth extraction were participated in this clinical research. They underwent trans-alveolar extraction of 40 teeth. The extraction sockets were divided in each patient into 2 groups: the study group in which extraction sockets were treated with PRF and the control group: in which extraction sockets left to heal naturally without PRF. Platelet-rich fibrin enhanced soft tissue healing and reduced inflammatory process within the study group compared with control group as the 2-tailed P value equaled 0.0035 which was very statistically significant. Pain level according to visual analog scale in control group had average of (1.8), while in the study group had average of (0.65) and the P value equaled 0.1511 which was not statistically significant. Degree of epithelization was recorded by dental caliper for both groups and the 2-tailed P value equaled 0.7134 which was insignificant. The results from this study showed that PRF enhanced the quality of soft tissue healing of extraction socket among smoker patients but it did not show significant difference regarding pain reduction, dry socket prevention, and socket closure. Future clinical trials are required to clearly identify the effectiveness of PRF regarding this subject.
28 September 2015 in Journal of Medical Engineering & Technology
(2015). Functional electrical stimulation for the upper limb in tetraplegic spinal cord injury: a systematic review. Journal of Medical Engineering & Technology: Vol. 39, No. 7, pp. 419-423. doi: 10.3109/03091902.2015.1088095
1 March 2017 in Journal of Craniofacial Surgery
SASahar Shakir Bds Al-Adili
Sahar Shakir Bds Al-Adili
Many treatment modalities have been introduced for correction of deficient alveolar ridge width. Bone expansion through the ridge split procedure is one of them. This technique was initiated in order to overcome many problems that usually associated with grafting procedures. The present study evaluated the effectiveness of piezoelectric device in performing ridge split using single-stage approach and assessed the outcomes during a period of about 4 months after surgery. A total of 23 patients aged in range between 18 and 60 years underwent ridge split procedure with immediate insertion of dental implants. A panoramic radiograph was obtained before surgery. The gained bone was measured and surgical complications were recorded. Implants stability was measured using Osstell device. Postoperative clinical complications were assessed. After a healing period of 16 weeks, all the implants were uncovered and evaluated regarding clinical, radiographic, and resonance frequency analysis findings. The totally implemented ridge split procedures were 26 cases including 57 implants inserted immediately at the time of surgery. The initial ridge width varied between 1 and 3.5 mm while the final width ranged from 5.5 to 8 mm. The minimum bone gain was 2.5 mm and the maximum value reached up to 7 mm. Few and insignificant clinical complications were recorded during the whole study. The survival rate was 100%. The study results indicated that piezoelectric ridge splitting technique is an effective, safe, and minimally invasive procedure. This technique has showed to be very successful in reducing the overall treatment period.
1 January 2024 in The Scientific World Journal
Purpose: This study aimed to evaluate the influence of vitamin D3 levels on bone density, primary dental implant stability, and successful osseointegration.Materials and Methods: Clinical and radiological examination with a standardized cone‐beam computed tomography (CBCT) machine and laboratory investigation for serum levels of vitamin D3 were performed for all patients. Only patients in need of single or multiple straightforward dental implant surgery in either jaw with no history of systemic disease or condition that may interfere with bone healing were included in this study to receive the dental implant by the same oral and maxillofacial surgeon, which re‐opened 4 months later to assess the osseointegration and to complete the prosthetic part.Results: One hundred twenty‐eight dental implants were inserted into 108 patients. Most of the patients in the study had insufficient vitamin D3 levels. The prognosis of dental implants regarding successful osseointegration 4 months after implant placement had a weak positive association with the insertion torque and bone mineral density and a statistically significant positive correlation with the serum vitamin D3 level.Conclusion: Preoperatively, it is advisable to request the serum vitamin D3 level of the patients along with the standard clinical and radiological examination. Severe vitamin D3 deficiency could be associated with early dental implant failure despite the favorable bone density and primary dental implant stability achieved.Trial Registration: ClinicalTrials.gov identifier: TCTR20200304001.
31 August 2020 in BMC Oral Health
Background: The purpose of this study was to evaluate the anesthetic effectiveness of a buccal infiltration technique combined with local massage (using 2% lidocaine) in the extraction of mandibular premolars to be utilized as an alternative to the conventional inferior alveolar nerve block.Methods: Patients eligible included any subject with a clinical indication for tooth extraction of the mandibular 1st or 2nd premolars. All patients were anesthetized buccally by local infiltration technique followed by an external pressure applied for 1 min directly over the injection area. In each case, another local injection was given lingually. All operations were started at approximately 5 min after the buccal injection. The collected data included age, gender, pain perception and its intensity during treatment at three checkpoints, apical tenderness, and the type of extraction. Any associated complications or difficulties were also recorded. Then the results were analyzed and interpreted using appropriate statistical tests. The significance level was set atP ≤ 0.05.Results: A total of 247 cases (1st premolar,n = 119; 2nd premolar,n = 128), predominantly male, were included. In 95% of study sample, the patients were satisfied with the dental extraction without any pain. However, in 5% of cases, pain was reported at the stage of tooth removal. Apical tenderness was found to be present in 11% of the total cases. Three teeth required surgical removal. Upon analysis, no significant differences in the success rates were detected between the 2 premolar groups or amongst the various age groups. Minor and transient side effects were reported in this study.Conclusion: The technique is simple and effective as well. It might be considered as an alternative anesthetic injection to the inferior alveolar nerve block for dental extraction of the mandibular premolars.
6 April 2020 in BMC Oral Health
Background: The posterior regions of the jaws usually represent a significant risk for implant surgery. A non-valid assessment of the available bone height may lead to either perforation of the maxillary sinus floor or encroachment of the inferior alveolar nerve and consequently to implant failure. This study aimed to evaluate the reliability of surgeon’s decision in appraising the appropriate implant length, in respect to vital anatomical structures, using panoramic radiographs.Methods: Only implants that are inserted in relation to the maxillary sinus (MS) or the mandibular canal (MC) were enrolled (first premolars [1P], second premolars [2P], first molars [1M], and second molars [2M]). All preoperative panoramic radiographs were evaluated under standard conditions. The postoperative estimation (under/over) was determined depending on the available bone height (ABH) measured from the apical end of the implant to the floor of the MS and the roof of the MC using cone beam computed tomography (CBCT). Any complication or side effect that associated with overestimated implants insertion was recorded.Results: The study sample included 73 patients (predominantly females) who had consecutively received 148 implants, of which 68 were inserted in the posterior maxilla and 80 in the posterior mandible. Underestimation was recorded in 93.2% of the measurements. The remaining bone height after implants insertion was < 2 mm in the majority of underestimated cases (73.9%); they were significantly (P < 0.01) more than sites with remaining bone ≥ 2 mm (26.1%). In the posterior mandible, overestimation was significantly higher than posterior maxilla. Five cases with transient paresthesia were reported in the mandibular overestimated implants.Conclusions: This study specified that surgeon’s choice of implants length, based on panoramic radiographs, was reliable regarding the incapability to insert implants with further length in the majority of underestimated cases, the low percent of overestimated measurements, and the minor associated complications.