Ge Zhang

Ge Zhang

Auto-generated profile, based on publicly available information

Ge Zhang

Department of Biomedical Engineering, Fourth Military Medical University, Xi’an 710032, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Lin YangLin Yang
Lin Yang
GZGe Zhang
Ge Zhang
JSJiali Song
Jiali Song
Meng DaiMeng Dai
Meng Dai
CXCanhua Xu
Canhua Xu
FFFeng Fu
Feng Fu
Stroke is a severe cerebrovascular disease and is the second greatest cause of death worldwide. Because diagnostic tools (CT and MRI) to detect acute stroke cannot be used until the patient reaches the hospital setting, a portable diagnostic tool is urgently needed. Because biological tissues have different impedance spectra under normal physiological conditions and different pathological states, multi-frequency electrical impedance tomography (MFEIT) can potentially detect stroke. Accurate impedance spectra of normal brain tissue (gray and white matter) and stroke lesions (ischemic and hemorrhagic tissue) are important elements when studying stroke detection with MFEIT. To our knowledge, no study has comprehensively measured the impedance spectra of normal brain tissue and stroke lesions for the whole frequency range of 1 MHz within as short as possible an ex vivo time and using the same animal model. In this study, we established intracerebral hemorrhage and ischemic models in rabbits, then measured and analyzed the impedance spectra of normal brain tissue and stroke lesions ex vivo within 15 min after animal death at 10 Hz to 1 MHz. The results showed that the impedance spectra of stroke lesions significantly differed from those of normal brain tissue; the ratio of change in impedance of ischemic and hemorrhagic tissue with regard to frequency was distinct; and tissue type could be discriminated according to its impedance spectra. These findings further confirm the feasibility of detecting stroke with MFEIT and provide data supporting further study of MFEIT to detect stroke.

7 April 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Lin YangLin Yang
Lin Yang
WLwenbo liu
wenbo liu
RCRongqing Chen
Rongqing Chen
GZGe Zhang
Ge Zhang
WLWeichen Li
Weichen Li
XDXiuzhen Dong
Xiuzhen Dong
Acute stroke is a serious cerebrovascular disease and has been the second leading cause of death worldwide. Conventional diagnostic modalities for stroke, such as CT and MRI, may not be available in emergency settings. Hence, it is imperative to develop a portable tool to diagnose stroke in a timely manner. Since there are differences in impedance spectra between normal, hemorrhagic and ischemic brain tissues, multi-frequency electrical impedance tomography (MFEIT) shows great promise in detecting stroke. Measuring the impedance spectra of healthy, hemorrhagic and ischemic brain in vivo is crucial to the success of MFEIT. To our knowledge, no research has established hemorrhagic and ischemic brain models in the same animal and comprehensively measured the in vivo impedance spectra of healthy, hemorrhagic and ischemic brain within 10 Hz–1 MHz. In this study, the intracerebral hemorrhage and ischemic models were established in rabbits, and then the impedance spectra of healthy, hemorrhagic and ischemic brain were measured in vivo and compared. The results demonstrated that the impedance spectra differed significantly between healthy and stroke-affected brain (i.e., hemorrhagic or ischemic brain). Moreover, the rate of change in brain impedance following hemorrhagic and ischemic stroke with regard to frequency was distinct. These findings further validate the feasibility of using MFEIT to detect stroke and differentiate stroke types, and provide data supporting for future research.

7 January 2017 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
GZGe Zhang
Ge Zhang
Meng DaiMeng Dai
Meng Dai
Lin YangLin Yang
Lin Yang
LWLi Weichen
Li Weichen
HLHaoting Li
Haoting Li
FFFeng Fu
Feng Fu
Electrode disconnection is a common occurrence during long-term monitoring of brain electrical impedance tomography (EIT) in clinical settings. The data acquisition system suffers remarkable data loss which results in image reconstruction failure. The aim of this study was to: (1) detect disconnected electrodes and (2) account for invalid data. Weighted correlation coefficient for each electrode was calculated based on the measurement differences between well-connected and disconnected electrodes. Disconnected electrodes were identified by filtering out abnormal coefficients with discrete wavelet transforms. Further, previously valid measurements were utilized to establish grey model. The invalid frames after electrode disconnection were substituted with the data estimated by grey model. The proposed approach was evaluated on resistor phantom and with eight patients in clinical settings. The proposed method was able to detect 1 or 2 disconnected electrodes with an accuracy of 100%; to detect 3 and 4 disconnected electrodes with accuracy of 92 and 84% respectively. The time cost of electrode detection was within 0.018 s. Further, the proposed method was capable to compensate at least 60 subsequent frames of data and restore the normal image reconstruction within 0.4 s and with a mean relative error smaller than 0.01%. In this paper, we proposed a two-step approach to detect multiple disconnected electrodes and to compensate the invalid frames of data after disconnection. Our method is capable of detecting more disconnected electrodes with higher accuracy compared to methods proposed in previous studies. Further, our method provides estimations during the faulty measurement period until the medical staff reconnects the electrodes. This work would improve the clinical practicability of dynamic brain EIT and contribute to its further promotion.

1 December 2015 in Materials Express
Verified
Journal Article
Closed access
ALAnming Li
Anming Li
JLJingzhao Li
Jingzhao Li
ZCZhenqiang Chen
Zhenqiang Chen
Yonghua WuYonghua Wu
Yonghua Wu
LWLidan Wu
Lidan Wu
GZGe Zhang
Ge Zhang

9 May 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
GZGe Zhang
Ge Zhang
LWLi Weichen
Li Weichen
HMHang Ma
Hang Ma
XLXuechao Liu
Xuechao Liu
Meng DaiMeng Dai
Meng Dai
FFFeng Fu
Feng Fu
Head movement interferences are a common problem during prolonged dynamic brain electrical impedance tomography (EIT) clinical monitoring. Head movement interferences mainly originate from body movements of patients and nursing procedures performed by medical staff, etc. These body movements will lead to variation in boundary voltage signals, which affects image reconstruction. This study employed a data preprocessing method based on wavelet decomposition to inhibit head movement interferences in brain EIT data. Mixed Gaussian models were applied to describe the distribution characteristics of brain EIT data. We identified head movement signal through the differences in distribution characteristics of corresponding wavelet decomposition coefficients between head movement artifacts and normal signals, and then managed the contaminated data with improved on-line wavelet processing methods. To validate the efficacy of the method, simulated signal experiments and human data experiments were performed. In the simulation experiment, the simulated movement artifact was significantly reduced and data quality was improved with indicators’ increase in PRD and correlation coefficient. Human data experiments demonstrated that this method effectively suppressed head movement in signals and reduce artifacts resulting from head movement artifacts in images. In this paper, we proposed an on-line strategy to manage the head movement interferences from the brain EIT data based on the distribution characteristics of wavelet coefficients. Our strategy is capable of reducing the movement interference in the data and improving the reconstructed images. This work would improve the clinical practicability of brain EIT and contribute to its further promotion.

20 June 2022
Verified
Conference Paper
Closed access
GZGe Zhang
Ge Zhang
QCQihang Chen
Qihang Chen
GKGi Kim
Gi Kim
SCSean Chang
Sean Chang
The technological importance of ALD (atomic layer deposition) process in the semiconductor business is more evident than ever before as the device structures become more and more challenging to deposit with various thin films. Therefore, it is highly beneficial to have more capable ALD equipment in the semiconductor manufacturing. The performance of a newly designed dual single-chamber ALD system has been evaluated by examination of basic process results obtained with the system. Al2O3 film was selected for the process characterization with the ALD chamber. The ALD growth linearity, and pulse-and-purge saturation behavior were evaluated. The degree of ALD saturation was also confirmed by step coverage test.