29 June 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MHMichael D. Harris
Michael D. Harris
ACAdam J. Cyr
Adam J. Cyr
AAAzhar A. Ali
Azhar A. Ali
CFClare K. Fitzpatrick
Clare K. Fitzpatrick
PRPaul J. Rullkoetter
Paul J. Rullkoetter
KSKevin B. Shelburne
Kevin B. Shelburne
Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged <2 deg during varus–valgus (VV) rotations, <6 deg during internal–external (IE) rotations, and <3 mm of translation during anterior–posterior (AP) displacements. Engagement of the individual ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community.

1 June 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
WBWilliam S. Burton
William S. Burton
CMCasey A. Myers
Casey A. Myers
PRPaul J. Rullkoetter
Paul J. Rullkoetter

29 January 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ANAlessandro Navacchia
Alessandro Navacchia
CMCasey A. Myers
Casey A. Myers
PRPaul J. Rullkoetter
Paul J. Rullkoetter
KSKevin B. Shelburne
Kevin B. Shelburne
Musculoskeletal models are powerful tools that allow biomechanical investigations and predictions of muscle forces not accessible with experiments. A core challenge modelers must confront is validation. Measurements of muscle activity and joint loading are used for qualitative and indirect validation of muscle force predictions. Subject-specific models have reached high levels of complexity and can predict contact loads with surprising accuracy. However, every deterministic musculoskeletal model contains an intrinsic uncertainty due to the high number of parameters not identifiable in vivo. The objective of this work is to test the impact of intrinsic uncertainty in a scaled-generic model on estimates of muscle and joint loads. Uncertainties in marker placement, limb coronal alignment, body segment parameters, Hill-type muscle parameters, and muscle geometry were modeled with a global probabilistic approach (multiple uncertainties included in a single analysis). 5–95% confidence bounds and input/output sensitivities of predicted knee compressive loads and varus/valgus contact moments were estimated for a gait activity of three subjects with telemetric knee implants from the “Grand Challenge Competition.” Compressive load predicted for the three subjects showed confidence bounds of 333 ± 248 N, 408 ± 333 N, and 379 ± 244 N when all the sources of uncertainty were included. The measured loads lay inside the predicted 5–95% confidence bounds for 77%, 83%, and 76% of the stance phase. Muscle maximum isometric force, muscle geometry, and marker placement uncertainty most impacted the joint load results. This study demonstrated that identification of these parameters is crucial when subject-specific models are developed.

19 April 2013 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
CFClare K. Fitzpatrick
Clare K. Fitzpatrick
CCChadd W. Clary
Chadd W. Clary
ACAdam J. Cyr
Adam J. Cyr
LMLorin P. Maletsky
Lorin P. Maletsky
PRPaul J. Rullkoetter
Paul J. Rullkoetter
Posterior‐stabilized (PS) total knee arthroplasty (TKA) components employ a tibial post and femoral cam mechanism to guide anteroposterior knee motion in lieu of the posterior cruciate ligament. Some PS TKA patients report a clicking sensation when the post and cam engage, while severe wear and fracture of the post; we hypothesize that these complications are associated with excessive impact velocity at engagement. We evaluated the effect of implant design on engagement dynamics of the post‐cam mechanism and resulting polyethylene stresses during dynamic activity. In vitro simulation of a knee bend activity was performed for four cadaveric specimens implanted with PS TKA components. Post‐cam engagement velocity and flexion angle at initial contact were determined. The experimental data were used to validate computational predictions of PS mechanics using the same loading conditions. A lower limb model was subsequently utilized to compare engagement mechanics of eight TKA designs, relating differences between implants to geometric design features. Flexion angle and post‐cam velocity at engagement demonstrated considerable ranges among designs (23°–89°, and 0.05–0.22 mm/°, respectively). Post‐cam velocity was correlated (r = 0.89) with tibiofemoral condylar design features. Condylar geometry, in addition to post‐cam geometry, played a significant role in minimizing engagement velocity and forces and stresses in the post. This analysis guides selection and design of PS implants that facilitate smooth post‐cam engagement and reduce edge loading of the post. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1438–1446, 2013

1 June 2020 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
WBWilliam Burton
William Burton
CMCasey Myers
Casey Myers
PRPaul Rullkoetter
Paul Rullkoetter

6 August 2015 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
JIJohn C. Ivester
John C. Ivester
ACAdam J. Cyr
Adam J. Cyr
MHMichael D. Harris
Michael D. Harris
MKMartin J. Kulis
Martin J. Kulis
PRPaul J. Rullkoetter
Paul J. Rullkoetter
KSKevin B. Shelburne
Kevin B. Shelburne
Relative motions within normal and pathological joints of the human body can occur on the sub-millimeter and sub-degree scale. Dynamic radiography can be used to create a rapid sequence of images from which measurements of bone motion can be extracted, but available systems have limited speed and accuracy, limit normal subject movement, and do not easily integrate into existing traditional motion capture laboratories. A high-speed stereo radiography (HSSR) system is described that addresses these limitations. The custom radiography system was placed on a standalone reconfigurable gantry structure designed to allow freedom of subject movement while integrating into an existing motion capture laboratory. Validation of the system and measurement of knee kinematics of subjects during gait confirmed the ability to record joint motion with high accuracy and high-speed.