Adnan Şimşek

Adnan Şimşek

Auto-generated profile, based on publicly available information

Adnan Şimşek

TUBITAK Ulusal Metroloji Enstitüsü, Barıs mah. Dr. Zeki Acar cad. No:1, 41470 Gebze/KOCAELI, Turkey

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Metrologia
Verified
Journal Article
Closed access
MCMichelle M G Chartrand
Michelle M G Chartrand
ICIan Chubchenko
Ian Chubchenko
PDPhilip J H Dunn
Philip J H Dunn
BGBruno Carius Garrido
Bruno Carius Garrido
HLHai Lu
Hai Lu
JMJuris Meija
Juris Meija
Main text: The CCQM Isotope Ratio Working Group (IRWG) determined that an additional key comparison of carbon isotope delta measurements was required to capture the progress of this field. Vials containing 0.25 mg of vanillin were prepared at NRC, and evaluated for bottle-to-bottle homogeneity prior to distribution to the eight participating institutes. Participants were able to choose any suitable method and reference materials for carbon isotope delta measurements, and report a carbon isotope delta value and the associated uncertainty, and analysis details. To determine the key comparison reference value (KCRV) and its associated uncertainty, the NRC in collaboration with the NIST, developed a multivariate Bayesian random laboratory effects model, which also incorporates the uncertainty due to bottle-to-bottle homogeneity and any correlations between the reported results that arise due to the use of common reference materials. The KCRV for this study was determined to be -25.833 ‰ relative to the VPDB, with associated uncertainty of 0.028 ‰, and expanded uncertainty of 0.056 ‰ (k=2). All the results reported by the participants in this study were considered equivalent to the KCRV. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

10 April 2019 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
PDPhilip J.H. Dunn
Philip J.H. Dunn
MBMine Bilsel
Mine Bilsel
AŞAdnan Şimşek
Adnan Şimşek
AGAhmet Ceyhan Goren
Ahmet Ceyhan Goren
MTMurat Tunç
Murat Tunç
HGHeidi Goenaga-Infante
Heidi Goenaga-Infante

23 March 2020
Verified
Conference Paper
Open access
ABAylin Boztepe
Aylin Boztepe
TTTanıl Tarhan
Tanıl Tarhan
ZŞZeynep Gülsoy Şerif
Zeynep Gülsoy Şerif
AŞAdnan Şimşek
Adnan Şimşek
Climate change is one of the most urgent issues facing humanity today. Humans have been rapidly changing the balance of gases in the atmosphere which causes global warming. Burning fossil fuels like coal and oil, farming and forestry, agriculture and cement manufacture cause to release water vapor, carbon dioxide (CO2), methane (CH4), ozone and nitrous oxide (N2O) known as the primary greenhouse gases. According to Intergovernmental Panel on Climate Change (IPCC), carbon dioxide is the most common greenhouse gas absorbing infrared energy emitted from the earth, preventing it from returning to space. It is necessary to separate man-made (anthropogenic) emissions from natural contributions in the atmosphere to obtain accurate emission data [1-4]. Since it could not be achieved with the existing metrological infrastructure, it is required to develop the measurements and references of stable isotopes of CO2. In this study, static and dynamic reference materials for pure CO2 at 400 µmol/mol in air matrix were prepared and it was provided to simulate CO2 gas in the atmosphere.The static gas mixtures were prepared gravimetrically in accordance with the ISO 6142-1 standard. In order to obtain CO2 gas at desired isotopic compositions, commercial CO2 gases were also supplied from abroad. Their isotopic compositions were measured by using GC-IRMS. Before filling, aluminum cylinders were evacuated until the pressure of 10-7 mbar using turbo-molecular vacuum pump. Isotopic compositions of reference materials were determined in a way that covering the range -42 ‰ to +1 ‰ vs VPDB for d13C-CO2 and -35 ‰ to -8 ‰ vs VPDB for d18O. In order to develop static and dynamic reference materials of CO2 at 400 µmol/mol in air with the uncertainty targets of d13C-CO2 0.1 ‰ and d18O-CO2 0.5 ‰, previously prepared pure CO2 reference gases were used. Dynamic dilution system with the high accuracy was constructed to generate dynamic reference gas mixture of CO2 at 400 µmol/mol. System contains 3 electronic pressure controllers, 3 thermal mass flow controllers with various capacities and 3 molbloc-L flow elements commanded with 2 Molboxes. The isotopic compositions of dynamic reference gas mixtures of CO2 at 400 µmol/mol were aimed to be same with the previously prepared pure CO2 reference gases. The whole dilution system were calibrated at INRIM to achieve lower uncertainties around 0.07-0.09%. At the measurement stage, CRDS and GC-IRMS equipments are operated simultaneously to determine the concentrations and isotopic compositions of the gas mixtures. The amount of substance fractions of the dynamic reference mixtures are calculated according to ISO 6145-7 standard. It will be checked that whether the isotopic compositions of the gravimetrically prepared pure CO2 reference gases and the dynamic reference gas mixtures of CO2 at 400 µmol/mol were same or not.REFERENCES[1] Calabro P. S., “Greenhouse gases emission from municipal waste management: The role of separate collection”, Waste Management, Volume 29:7, 2178-2187, 2009.[2] Sources of Greenhouse Gas Emissions, United States Environmental Protection Agency, https://www.epa.gov/ghgemissions/sources-greenhouse-gas-emissions, 2019.[3] Schwartz, S.E., “The Greenhouse Effect and Climate Change”, 2017.[4] Climate Change, The Intergovernmental Panel on Climate Change, https://www.ipcc.ch/report/ar4/wg1, 2019.