24 February 2025 in Measurement Science and Technology
Acquiring high-precision and robust calibration methods for determining the intrinsic and extrinsic parameters of cameras is essential to ensuring the accuracy of visual measurements and three-dimensional reconstruction. This paper addresses the challenge of reduced calibration accuracy in camera systems caused by eccentricity errors in the extraction of circular target feature centers. We propose a precise calibration method that corrects these eccentricity errors associated with circular targets. The method begins by solving for the homography matrix of each calibration image using the coordinates of both image points and target points. Subsequently, the homography matrix is used to generate the frontal view of the circular target, enabling the precise extraction and back-mapping of the circular target’s center based on this frontal view. Finally, using the corrected coordinates of the circle center and the calibration method proposed by Zhang in the paper ‘A Flexible New Technique for Camera Calibration’, we accurately determine the intrinsic and extrinsic parameters of the camera. Simulation experiments show the proposed calibration method aligns perfectly with ground truth without noise. In practical tests, it outperformed the checkerboard and traditional circular target methods, reducing reprojection errors by 0.0295 and 0.0176 pixels, respectively. Additionally, the cross-ratio experiment showed a 0.076% reduction in error for corrected circle center points. These results highlight significant improvements in calibration accuracy, meeting high-precision needs in visual sensing.
29 May 2024 in Measurement Science and Technology
Accurately calibrate the extrinsic parameters between a camera and an Inertial Measurement Unit (IMU) is a prerequisite for achieving sensor data fusion in visual-inertial navigation systems. Due to delays introduced by triggering, transmission, and other factors, the sampled times of the camera and IMU do not align with the system timestamps, leading to a decrease in the accuracy of extrinsic calibration. Existing calibration methods are unable to avoid the temporal misalignment between the camera and IMU. This paper introduces a novel intermittent calibration sampling method to address temporal misalignment challenges. The approach entails detecting motion-stillness transition points in the IMU data as keyframe segmentation criteria, thereby decoupling data acquisition from system timestamps and aligning it with the sensor’s motion process. Subsequently, the robot hand-eye calibration method is applied to the extrinsic calibration of the Camera-IMU, combining the Random Sample Consensus algorithm to filter the poses of the camera and IMU. This process achieves precise calibration of extrinsic parameters. Experimental validation shows that the algorithm proposed in this paper enhances calibration accuracy when compared to the widely used Kalibr Camera-IMU calibration toolbox. The rotational extrinsic parameter accuracy increased by 181.25%, and the translational extrinsic parameter accuracy improved by 168.33%. These findings provide effective technical means for precise measurement of Camera-IMU extrinsic parameters.