Piotr Łukasiewicz

Piotr Łukasiewicz

Auto-generated profile, based on publicly available information

Piotr Łukasiewicz

Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Clinics in Shoulder and Elbow
Verified
Journal Article
Open access
PDF file
PAPunyawat Apiwatanakul
Punyawat Apiwatanakul
PMPrashant Meshram
Prashant Meshram
AHAndrew Harris
Andrew Harris
JBJoel Bervell
Joel Bervell
PŁPiotr Łukasiewicz
Piotr Łukasiewicz
EMEdward G. McFarland
Edward G. McFarland
Background:Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications.Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported.Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1–10.7 months), compared with 5.5 months (range, 2–8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device.Level of evidence: III.

17 May 2023 in Journal of ISAKOS
Verified
Journal Article
Open access
PLPiotr Lukasiewicz
Piotr Lukasiewicz
EMEdward McFarland
Edward McFarland
JHJeffrey D. Hassebrock
Jeffrey D. Hassebrock
TMTimothy P. McCarthy
Timothy P. McCarthy
SSStephen M. Sylvia
Stephen M. Sylvia
SWStephen C. Weber
Stephen C. Weber
Anatomical total shoulder arthroplasty (aTSA) in its modern form where it reproduces the normal shoulder has been utilized clinically for more than half a century. As the technology and the designs have changed to recreate the humeral and glenoid sides of the joint, the sophistication of design has resulted in the growing number of cases annually worldwide. This increase is due in part to the increasing number of indications that the prosthesis can treat with successful results. On the humeral side there have been design changes to better reflect the proximal humeral anatomy, and humeral stems are increasingly placed safely without cement. Platform systems which allow conversion of a failed arthroplasty to a reverse configuration without stem extraction is another design change. Similarly, there has been increasing utilization of short stem and stemless humeral components. Extensive experience with shorter stem and stemless devices however has yet to demonstrate the purported advantages of these devices, as recent studies have demonstrated equivalent blood loss, fracture rates, operative times, and outcome scores. Easier revision with these shorter stems remains to be definitively established, with only one study comparing ease of revision between stem types. On the glenoid side, hybrid cementless glenoids, inlay glenoids, cementless all-polyethylene glenoids, and augmented glenoids have all been investigated, however the indications for these devices remain unclear. Lastly, innovative surgical approaches to implanting shoulder arthroplasty and the use of patient specific guides and computerized planning, while interesting concepts, still await validation before they are utilized on a widespread basis. While reverse shoulder arthroplasty has been increasingly used to reconstruct the arthritic shoulder, anatomic glenohumeral replacement maintains a significant role in the armamentarium of the shoulder surgeon.

1 July 2023 in Annals of Joint
Verified
Journal Article
Open access
PDF file
PŁPiotr Łukasiewicz
Piotr Łukasiewicz
AHAndrew Harris
Andrew Harris
JBJoel A. Bervell
Joel A. Bervell
EMEdward G. McFarland
Edward G. McFarland
Background and Objective: Reverse shoulder arthroplasty has become a common orthopaedic procedure, with a growing number of cases annually for multiple indications, such as rotator cuff arthropathy, osteoarthritis, or fractures of the proximal humerus, to reduce pain and restore shoulder mobility. Prosthesis design and various recent improvements aim to enhance range of motion (ROM) and stability and to limit component loosening and other potential complications. Many of these well-known issues could theoretically be improved by glenoid, humeral, or combined component lateralization. The objective of this article is to provide an up-to-date literature overview, present available options, and discuss the rationale behind lateralization of certain components, as well as their combined impact on outcomes of reverse shoulder arthroplasty. Methods: PubMed and Scopus databases from 2003 to 2023 were searched and screened for studies, including systematic reviews, on the influence of glenoid, humeral, and combined component lateralization that served for narrative review of rationale behind such design. Key Content and Findings: Currently, a number of computer simulations, anatomic studies, and limited clinical references aim to support the rationale behind glenoid augmentation, variable humeral neck-shaft angle (NSA), or humeral tray design. Conclusions: The utility of lateralization has not yet been clinically established. Randomized, long-term clinical outcome studies are still needed to reach a verdict going beyond surgeon preference and case-specific indications.

14 May 2024 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
PMPrashant Meshram
Prashant Meshram
PŁPiotr Łukasiewicz
Piotr Łukasiewicz
LOLaurence Okeke
Laurence Okeke
USUma Srikumaran
Uma Srikumaran
EMEdward G. McFarland
Edward G. McFarland

9 October 2024 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
RMRidge Maxson
Ridge Maxson
PMPrashant Meshram
Prashant Meshram
AHAndrew Harris
Andrew Harris
CLChristopher R. Leland
Christopher R. Leland
JLJim Lu
Jim Lu
EMEdward G. McFarland
Edward G. McFarland

5 August 2025 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
EMEdward G. McFarland
Edward G. McFarland
LOLaurence Okeke
Laurence Okeke
PMPrashant Meshram
Prashant Meshram
JBJoel A. Bervell
Joel A. Bervell
PŁPiotr Łukasiewicz
Piotr Łukasiewicz
JPJames H. Padley
James H. Padley