Yonatan Chatzinoff

Yonatan Chatzinoff

Auto-generated profile, based on publicly available information

Yonatan Chatzinoff

Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RCRajiv Chopra
Rajiv Chopra
SSSumbul Shaikh
Sumbul Shaikh
YCYonatan Chatzinoff
Yonatan Chatzinoff
IMImalka Munaweera
Imalka Munaweera
BCBingbing Cheng
Bingbing Cheng
DGDavid E. Greenberg
David E. Greenberg
Treatment of prosthetic joint infection (PJI) usually requires surgical replacement of the infected joint and weeks of antibiotic therapy, due to the formation of biofilm. We introduce a non-invasive method for thermal destruction of biofilm on metallic implants using high-frequency (>100 kHz) alternating magnetic fields (AMF). In vitro investigations demonstrate a >5-log reduction in bacterial counts after 5 minutes of AMF exposure. Confocal and scanning electron microscopy confirm removal of biofilm matrix components within 1 minute of AMF exposure, and combination studies of antibiotics and AMF demonstrate a 5-log increase in the sensitivity of Pseudomonas aeruginosa to ciprofloxacin. Finite element analysis (FEA) simulations demonstrate that intermittent AMF exposures can achieve uniform surface heating of a prosthetic knee joint. In vivo studies confirm thermal damage is confined to a localized region (<2 mm) around the implant, and safety can be achieved using acoustic monitoring for the presence of surface boiling. These initial studies support the hypothesis that AMF exposures can eradicate biofilm on metal implants, and may enhance the effectiveness of conventional antibiotics.

1 September 2017 in Investigative Radiology
Verified
Journal Article
Open access
DCDaniel Costa
Daniel Costa
YCYonatan Bsmed Chatzinoff
Yonatan Bsmed Chatzinoff
NPNiccolo M. Passoni
Niccolo M. Passoni
PKPayal Kapur
Payal Kapur
CRClaus G. Roehrborn
Claus G. Roehrborn
RCRajiv Chopra
Rajiv Chopra
Objectives: The aim of this study was to compare the anatomical registration of preoperative magnetic resonance imaging (MRI) and prostate whole-mount obtained with 3D-printed, patient-specific, MRI-derived molds (PSM) versus conventional whole-mount sectioning (WMS). Materials and Methods: Based on an a priori power analysis, this institutional review board–approved study prospectively included 50 consecutive men who underwent 3 T multiparametric prostate MRI followed by radical prostatectomy. Two blinded and independent readers (R1 and R2) outlined the contours of the prostate, tumor, peripheral, and transition zones in the MRI scans using regions of interest. These were compared with the corresponding regions of interest from the whole-mounted histopathology, the reference standard, using PSM whole-mount results obtained in the study group (n = 25) or conventional WMS in the control group (n = 25). The spatial overlap across the MRI and histology data sets was calculated using the Dice similarity coefficient (DSC) for the prostate overall (DSCprostate), tumor (DSCtumor), peripheral (DSCPZ), and transition (DSCTZ) zone. Results in the study and control groups were compared using Wilcoxon rank sum test. Results: The MRI histopathology anatomical registration for the prostate gland overall, tumor, peripheral, and transition zones were significantly superior with the use of PSMs (DSCs for R1: 0.95, 0.86, 0.84, and 0.89; for R2: 0.93, 0.75, 0.78, and 0.85, respectively) than with the use of standard WMS (R1: 0.85, 0.46, 0.66, and 0.69; R2: 0.85, 0.46, 0.66, and 0.69) (P < 0.0001). Conclusions: The use of PSMs for prostate specimen whole-mount sectioning provides significantly superior anatomical registration of in vivo multiparametric MRI and ex vivo prostate whole-mounts than conventional WMS.

9 April 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ZWZhiyue J. Wang
Zhiyue J. Wang
YPYong Jong Park
Yong Jong Park
MMMichael C. Morriss
Michael C. Morriss
YSYoungseob Seo
Youngseob Seo
TNTrung Nguyen
Trung Nguyen
NRNancy K. Rollins
Nancy K. Rollins
Susceptibility artifacts caused by stainless steel orthodontic appliances (braces) pose significant challenges in clinical brain MRI examinations. We introduced field correction device (FCD) utilizing permanent magnets to cancel the induced B0inhomogeneity and mitigate geometric distortions in MRI. We evaluated a prototype FCD using a 3D-printed head phantom in this proof of concept study. The phantom was compartmented into anterior frontal lobe, temporal lobe, fronto-parieto-occipital lobe, basal ganglia and thalami, brain stem, and cerebellum and had built-in orthogonal gridlines to facilitate the quantification of geometric distortions and volume obliterations. Stainless steel braces were mounted on dental models of three different sizes with total induced magnetic moment 0.15 to 0.17 A·m2. With braces B0standard deviation (SD) ranged from 2.8 to 3.7 ppm in the temporal and anterior frontal lobes vs. 0.2 to 0.3 ppm without braces. The volume of brain regions in diffusion weighted imaging was obliterated by 32–38% with braces vs. 0% without braces in the cerebellum. With the FCD the SD of B0ranged from 0.3 to 1.2 ppm, and obliterated volume ranged from 0 to 6% in the corresponding brain areas. These results showed that FCD can effectively decrease susceptibility artifacts from orthodontic appliances.