6 August 2020 in IEEE Sensors Journal
Additive Manufacturing (AM), or 3D printing, is a powerful technology that is revolutionizing the way designers create products across many industries. AM technology is severely limited by the lack of effective methods for in situ characterization of multi-material properties and composition during printing. The ability to detect the composition of multi-material printed inks in real time is an emerging need for a wide range of manufacturing applications. In this study, dielectric properties of embedded metal microparticles in a dielectric matrix are measured and characterized as a function of particle size, shape, volume percentage and frequency. Unexpectedly, there was no observation of any percolation threshold. The impedance was found to decrease with the percentage of metal filler as expected. While particle shape seemed to have significant effect on the impedance, there was little to no correlation between particle size and impedance. The resulting data can be used to generate a calibration curve correlating metal loading with impedance or capacitance. We discuss how this data can be used for in situ sensing of local ink composition, which does not currently exist, to facilitate greater control over the resulting properties and functionality of printed materials.
10 July 2018 in IEEE Transactions on Nuclear Science
We have developed a handheld γ ray spectrometer based on 1024 pixels, 2.8 mm × 2.8 mm × 6 mm in size, of GYGAG Garnet ((Gd,Y,Ce)3(Ga,Al)5O12) ceramic scintillator (total of 48 cm3 detector volume) coupled to silicon photodiode arrays. The silicon photodiode arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ ray spectroscopy has been implemented and a system user interface was developed that runs on an Android tablet. We have optimized the processing of the GYGAG(Ce) garnet, the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662 keV) = 3.1% FWHM, and full device resolution with singles events from all pixels summed of 4.5%. When Comptonsummed events are included, full-energy peak efficiency increases by ~2× and R(662 keV) = 4.7% is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ± 10 degrees in ~2 seconds.