Sameh Salem

Sameh Salem

Auto-generated profile, based on publicly available information

Sameh Salem

RUDN University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2024 in RUDN Journal of Medicine
Verified
Journal Article
Open access
PDF file
APAndrey V. Protasov
Andrey V. Protasov
MMMekhaeel Sh. F. Mekhaeel
Mekhaeel Sh. F. Mekhaeel
SSSameh M. A. Salem
Sameh M. A. Salem
Silver and titanium were the first used elements in the era of hernia-strengthening biomaterials about a hundred years ago, reaching up to 150 types nowadays. The uniqueness of Deeken and Lake Mesh Classification system is its dependence of the properties of the used materials in classifying them, where three main categories of meshes was established; permanent synthetic, absorbable (of biological origin) derived; furtherly divided into composite, non-composite types, and hybrid meshes. The physical characteristics of each category are determined by the pore size, thread diameter, thickness and density. Moreover, tear resistance, suture retention, uniaxial tensile and planar biaxial tensile testing, ball burst, make it possible to refine the properties of the mesh implant. This article is devoted to understanding the types of mesh materials used for repair of the anterolateral abdominal wall hernias by highlighting the properties of their scaffold materials, coating and barriers, as well as their improvement through coating by different several materials improving their properties in order to meet the needs of sufficient and satisfactory hernia repair seeking for leadership in choosing mesh implants.

27 April 2025 in Archiv Euromedica
Verified
Journal Article
Closed access
MMMekhaeel Mekhaeel
Mekhaeel Mekhaeel
Kazem Reza KashyzadehKazem Reza Kashyzadeh
Kazem Reza Kashyzadeh
APAndrey Protasov
Andrey Protasov
SSSameh Salem
Sameh Salem
WTWatban Khalid Al Tekreeti
Watban Khalid Al Tekreeti
AMAbanoub Mohareb
Abanoub Mohareb
Aims: This study aimed to evaluate the clinical outcomes of using polypropylene and polyester mesh implants in inguinal hernia repair via the Lichtenstein technique, employing artificial intelligence and machine learning tools for statistical analysis. Methods: A total of 58 patients with primary unilateral inguinal hernias were operated on using the Lichtenstein technique over a three-year period. They were divided into two groups: Group A (38 patients, mean age 58.05 years; 34 males, 4 females) received polypropylene meshes, while Group B (20 patients, mean age 50.05 years; all males) received polyester meshes. Data analysis was conducted using Python, incorporating machine learning algorithms to assess key clinical parameters including operative time, duration of hospital stay, and postoperative complications. Results: Statistical analysis using independent samples t-tests revealed no significant differences between the two groups in terms of hernia duration, operative time, length of hospital stay, or rate of postoperative complications. Conclusions: Polypropylene and polyester meshes demonstrate comparable performance in Lichtenstein hernia repair with no significant differences in surgical outcomes. Mesh selection may therefore be guided by patient-specific factors, surgeon preference, or cost considerations, rather than expected clinical superiority.

23 April 2024 in Russian Journal of Operative Surgery and Clinical Anatomy
Verified
Journal Article
Closed access
APA.V. Protasov
A.V. Protasov
MMM.SH.F. Mekhaeel
M.SH.F. Mekhaeel
SSS.M.A. Salem
S.M.A. Salem
Objective. Finding out the results of using two kinds of mesh implants: self-gripping mesh implants and polypropylene mesh fixed by tacks in open inguinal hernioplasty by Liechtenstein focusing on the way of mesh fixation. Material and methods. Our study was conducted upon 100 patients with inguinal hernia, which were divided into two equal groups (no=50). AdhesixTM self- gripping mesh implants was utilized in the first group, while polypropylene mesh implants fixed by elastic absorb tack fixing device were used in the second group. The duration of the operation, quantity of hospital stays (beds/day), postoperative complications and complications during the short-term follow-up were estimated. Results. Self-gripping mesh implants were superior to polypropylene mesh fixed by elastic tacks regarding operative time (8 minutes less), incidence of post-operative pain (28% less) and also foreign body sensation (34% less) during the short-term follow-up. Conclusion. We can recommend using self-gripping mesh in practice when the choice of surgeon well be between self-gripping mesh and polypropylene mesh fixed by tacks.

26 December 2024 in Archiv Euromedica
Verified
Journal Article
Closed access
SSSameh Salem
Sameh Salem
MMMekhaeel Mekhaeel
Mekhaeel Mekhaeel
APAndrey Protasov
Andrey Protasov
NTNada Taha
Nada Taha
AMArafa Mohamed
Arafa Mohamed
SNSalma Noureldin
Salma Noureldin
Aims: Studying the results of the reconstruction of pediatric multi-facial fracture. Case Description: In our study we present a 13-year-old boy with facial oedema, oral pain and bleeding due to falling from height. Upon examination, the patient had a left parasymphysial mandibular fracture and maxillary fracture Le fort I. Conclusions: A combined closed reduction with intermaxillary fixation and maxillary-frontal suspension and open reduction using interosseous wiring had restored the preoperative anatomical, functional and cosmetic aspects of the patient, which was found to be a reliable, cost-effective method for surgical management of pediatric facial trauma.

27 February 2026 in Surgery Case Reports
Verified
Journal Article
Open access
SSSameh Mohamed Ahmed Eissa Salem
Sameh Mohamed Ahmed Eissa Salem
MMMekhaeel Shehata Fakhry Mekhaeel
Mekhaeel Shehata Fakhry Mekhaeel
APAndrey Vitalevitch Protasov
Andrey Vitalevitch Protasov
MHMohamed Khaled Talaat Youssef Hassan
Mohamed Khaled Talaat Youssef Hassan
AJAida Jahanbekam
Aida Jahanbekam
TTTahoura Talebidelooei
Tahoura Talebidelooei

26 December 2024 in Archiv Euromedica
Verified
Journal Article
Closed access
MMMekhaeel Mekhaeel
Mekhaeel Mekhaeel
SSSameh Salem
Sameh Salem
APAndrey Protasov
Andrey Protasov
Aims: To find the results of using polyester mesh implant as an optimal alternative to polypropylene for open anterior inguinal hernia repair by Lichtenstein. Case Description: We present a 53-year-old-male patient with uncomplicated right-sided oblique inguinal hernia. Reinforcement of the posterior wall of the inguinal canal was done using polyester mesh implant fixed by dacron sutures. Successful repair was achieved with reduced operative-time and smooth recovery free from complications during post-operative and short-term follow-up intervals. Conclusions: Polyester mesh implant could be considered an optimal alternative to polypropylene for open anterior inguinal hernia repair.