1 February 2013 in Science
Nanoscale NMR with Diamond Defects: Although nuclear magnetic resonance (NMR) methods can be used for spatial imaging, the low sensitivity of detectors limits the minimum sample size. Two reports now describe the use of near-surface nitrogen-vacancy (NV) defects in diamond for detecting nanotesla magnetic fields from very small volumes of material (see the Perspective by
Hemmer
). The spin of the defect can be detected by changes in its fluorescence, which allows proton NMR of organic samples only a few nanometers thick on the diamond surface.
Mamin
et al.
(p. 557 ) used a combination of electron spin echoes and pulsed NMR manipulation of the proton spins to detect the very weak fields.
Staudacher
et al.
(p. 561 ) measured statistical polarization of a population of about 10 4 spins near the NV center with a dynamical decoupling method.
21 August 2015 in Physical Review Letters
We show that electric field noise from surface charge fluctuations can be a significant source of spin decoherence for near-surface nitrogen-vacancy (NV) centers in diamond. This conclusion is based on the increase in spin coherence observed when the diamond surface is covered with high-dielectric-constant liquids, such as glycerol. Double-resonance experiments show that improved coherence occurs even though the coupling to nearby electron spins is unchanged when the liquid is applied. Multipulse spin-echo experiments reveal the effect of glycerol on the spectrum of NV frequency noise.
13 August 2021 in Physical Review Applied
We demonstrate a superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon potentially offers a smaller footprint than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces the relative electric field participation from other interfaces. By combining micrometer-scale // junctions with long oxidations, we produce functional devices with in the low-transmon regime (). Cryogenic - measurements show a sharp structure with low subgap conduction. Qubit spectroscopy of tunable versions shows a small number of avoided level crossings, suggesting the presence of two-level systems. We observe mean times typically in the range of , with some annealed devices exhibiting over several hours. The results suggest that energy relaxation in conventional small-junction transmons is not limited by junction loss.
2 April 2008 in Physical Review Letters
We report on measurements of the spin lifetime of nuclear spins strongly coupled to a micromechanical cantilever as used in magnetic resonance force microscopy. We find that the rotating-frame correlation time of the statistical nuclear polarization is set by the magnetomechanical noise originating from the thermal motion of the cantilever. Evidence is based on the effect of three parameters: (1) the magnetic field gradient (the coupling strength), (2) the Rabi frequency of the spins (the transition energy), and (3) the temperature of the low-frequency mechanical modes. Experimental results are compared to relaxation rates calculated from the spectral density of the magnetomechanical noise.
23 August 2019 in Science
Nanoscience pioneer who invented advanced microscopes