Gretel Monreal

Gretel Monreal

Auto-generated profile, based on publicly available information

Gretel Monreal

Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GMGretel Monreal
Gretel Monreal
SKSteven C. Koenig
Steven C. Koenig
MSMark S. Slaughter
Mark S. Slaughter
GMGino F. Morello
Gino F. Morello
SPSteven R. Prina
Steven R. Prina
KDKurt A. Dasse
Kurt A. Dasse
Inspired Therapeutics (Merritt Island, FL) is developing a mechanical circulatory support (MCS) system designed as a single driver with interchangeable, extracorporeal, magnetically levitated pumps. The NeoMate system design features an integrated centrifugal rotary pump, motor, and controller that will be housed in a single compact unit. Conceptually, the primary innovation of this technology will be the combination of disposable, low-cost pumps for use with a single, multi-functional, universal controller to support multiple pediatric cardiopulmonary indications. In response to the paucity of clinically available pediatric devices, Inspired Therapeutics is specifically targeting the underserved neonate and infant heart failure (HF) patient population first. In this article, we present the development of the prototype Inspired Therapeutics NeoMate System for pediatric left ventricular assist device (LVAD) support, and feasibility testing in static mock flow loops (H-Q curves), dynamic mock flow loops (hemodynamics), and in an acute healthy ovine model (hemodynamics and clinical applicability). The resultant hydrodynamic and hemodynamic data demonstrated the ability of this prototype pediatric LVAD and universal controller to function over a range of rotary pump speeds (500–6000 RPM), to provide pump flow rates of up to 2.6 L/min, and to volume unload the left ventricle in acute animals. Key engineering challenges observed and proposed solutions for the next design iteration are also presented.

1 June 2015 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
ESErin M. Schumer
Erin M. Schumer
KZKeith A. Zoeller
Keith A. Zoeller
PLPaul L. Linsky
Paul L. Linsky
GMGretel Monreal
Gretel Monreal
YCYoung Joon Choi
Young Joon Choi
VBVictor H. van Berkel
Victor H. van Berkel

22 July 2024 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
GMGretel Monreal
Gretel Monreal
SKSteven C. Koenig
Steven C. Koenig
JKJames F. Kelley
James F. Kelley
JIJessica J. Illg
Jessica J. Illg
DTDaniel Tamez
Daniel Tamez
MSMark S. Slaughter
Mark S. Slaughter

10 February 2023 in ASAIO Journal
Verified
Journal Article
Closed access
GMGretel Monreal
Gretel Monreal
SKSteven C. Koenig
Steven C. Koenig
MTMustafa Ertan Taskin
Mustafa Ertan Taskin
CSCharles Jr Shambaugh
Charles Jr Shambaugh
JLJeffrey A. LaRose
Jeffrey A. LaRose
MSMark S. Slaughter
Mark S. Slaughter
RT Cardiac Systems (RTCS, Raleigh, NC) is developing an intravascular percutaneous mechanical circulatory support (pMCS) device drive system for use during high-risk percutaneous coronary intervention and emergent cardiogenic shock. The proprietary pMCS device (US patent 10,780,206) consists of a miniaturized axial flow pump with an integrated motor connected via a short flexible drive system. This novel flexible drive system creates a flexible pump that is advantageous for percutaneous placement and conforming to anatomy. This design also has the benefit of not requiring a continuous external lubrication source. In this article, we present engineering development and feasibility testing of the prototype pMCS system. Computational fluid dynamics (CFD) modeling was performed to evaluate candidate blade set designs (impeller leading and trailing edges, diffuser) and predict hydrodynamic performance and hemolysis risk. Bench testing of candidate lip seal designs (radial interference, durometer, and seal angle) was evaluated for leak rate. Two 16Fr prototype devices were then fabricated and tested in a static mock flow loop. Experimental testing demonstrated 3 L/min flow against 110 mmHg and 4 L/min flow against 80 mmHg, which matched the CFD-predicted hydrodynamic performance. These results demonstrate feasibility of the engineering design and performance of the prototype devices.

25 September 2025 in JTCVS Open
Verified
Journal Article
Open access
JCJoshua G. Crane
Joshua G. Crane
MSMark S. Slaughter
Mark S. Slaughter
SKSteven C. Koenig
Steven C. Koenig
GMGretel Monreal
Gretel Monreal
We test the hypothesis that pediatric arterial (“peds art”) cannulae as distal perfusion catheters (DPCs) for venoarterial extracorporeal membrane oxygenation provide more favorable distal limb hemodynamics than introducer sheaths. Introducer sheaths (Teleflex 5, 6, 8 Fr) and peds art cannulae (Medtronic 6, 8, 10 Fr) were tested as DPCs in static and dynamic mock loops. Flow through each and flow loss caused by their intravascular obstructiveness was measured to calculate pressure gradient versus flow, intravascular obstruction flow, and resistances. All 3 peds art cannulae tested delivered greater flows than the 3 introducer sheaths. The 10-Fr peds art cannula provided the most flow (0.97 L/min, 1500 rpm), whereas all 3 introducer sheaths provided much lower and nearly identical flows (only 0.18-0.20 L/min, 1500 rpm) despite their different diameters. The 10-Fr peds art cannula provided the most flow at equivalent head pressures despite being the most obstructive (least amount of flow around it, 2.0 L/min) relative to no DPC (2.5 L/min), resulting in the highest cumulative flow distally. The 10-Fr peds art cannula was the most beneficial DPC tested. All peds art cannulae tested possessed a better tradeoff of flow delivery versus intravascular obstructiveness compared to introducer sheaths, resulting in more favorable distal limb hemodynamics. The integrated stopcock with small holes (0.061′′ = 4.65 Fr) on the introducer sheath's sidearm and at the 90° sidearm's attachment to the sheath's hub increase resistance. These chokepoints of introducer sheaths prevent sufficient flow to support distal limb perfusion as DPC.

27 June 2025 in ASAIO Journal
Verified
Journal Article
Closed access
JCJoshua G. Crane
Joshua G. Crane
GMGretel Monreal
Gretel Monreal
SKSteven C. Koenig
Steven C. Koenig
MSMark S. Slaughter
Mark S. Slaughter
There are conflicting clinical data on whether the use of a distal perfusion catheter (DPC) is beneficial for reducing the risk of limb ischemia in peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO) patients. We investigated the hemodynamic effects of arterial cannula size, use of and size of a DPC, and ECMO flow (pump speed) on femoral artery hemodynamics in an adult peripheral VA-ECMO dynamic mock loop. The mock loop was tuned to heart failure conditions (cardiac output 3 L/min, arterial pressure 50 mm Hg, venous pressure 20 mm Hg). Three arterial cannulae (15Fr, 17Fr, 19Fr; right iliac) were each integrated into the loop with/without DPC (none, 5Fr, 8Fr; right superficial femoral artery [RSFA]), creating nine configurations tested. Hemodynamic pressures and flows were recorded over a range of pump speeds generating 0–3.5 L/min ECMO flow. The right femoral arteries demonstrated reduced flow, pressure, and pulsatility compared with the left across all cannula configurations and which worsened with increasing arterial cannula size and ECMO flow. Impaired right femoral hemodynamics were not improved with the use or size of DPC, suggesting that the increased resistance created by the presence of the arterial cannula and the DPC may be too great to overcome, thereby offsetting any potential flow benefits provided by the DPC. Export