James Lai

James Lai

Auto-generated profile, based on publicly available information

James Lai

Bascom Palmer Eye Institute at the University of Miami Miller School of Medicine, Miami, Florida

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2023 in Ophthalmology
Verified
Journal Article
Closed access
PPParastou Pakravan
Parastou Pakravan
JLJames Lai
James Lai
KCKara Cavuoto
Kara Cavuoto

4 February 2024 in Expert Review of Ophthalmology
Verified
Journal Article
Closed access
JLJames Lai
James Lai
YRYannis Rigas
Yannis Rigas
NKNicole B. Kantor
Nicole B. Kantor
NCNoah K. Cohen
Noah K. Cohen
ATAna Tomlinson
Ana Tomlinson
AGAnat Galor
Anat Galor

14 October 2019
Verified
Journal Article
Closed access
VSVivian M. Sueiras
Vivian M. Sueiras
FDFloriane Devaux
Floriane Devaux
BSBenjamin Smith
Benjamin Smith
JLJames Lai
James Lai
WBWyndham Batchelor
Wyndham Batchelor
NZNoel M. Ziebarth
Noel M. Ziebarth

18 January 2025 in Ophthalmology Science
Verified
Journal Article
Open access
JLJames M. Lai
James M. Lai
JCJustin Chen
Justin Chen
AFAaron J. Fils
Aaron J. Fils
LRLandon Rohowetz
Landon Rohowetz
WHWILLIAM Ross HERSKOWITZ
WILLIAM Ross HERSKOWITZ
NYNicolas A. Yannuzzi
Nicolas A. Yannuzzi
To investigate the mechanical properties of 23-, 25-, and 27-gauge trocars when subjected to representative pressures of posterior segment surgery. Experimental study. There were no subjects included in this study. Twenty-four trocars each from Alcon, Dutch Ophthalmic Research Center (DORC), and Bausch & Lomb (B/L), distributed evenly across 23-, 25-, and 27-gauge sizes were included in this study. These trocars were tested at both 40 mmHg and 60 mmHg of pressure. Two failure end points were identified, and each trocar was tested until it reached both failure points. The number of instrument exchanges required before trocar valve failure at 2 predesignated end points. A total of 72 measurements were made. Most notably between brands, 23-gauge Alcon trocars demonstrated significantly greater competence than their 23-gauge counterparts in B/L and DORC at both 40 mmHg and 60 mmHg pressures (P < 0.01). However, at the 25- and 27-gauge sizes, there were no significant differences in competence between trocar brands (P > 0.05). Based on the findings of this study, 23-gauge valved trocars from B/L and DORC exhibited a significantly lower threshold for compromise compared to that of Alcon valved trocars, likely attributable to differences in valve placement design. Surgeon experience, vitrector preference, and the specific type of surgery performed are important considerations in the choice of vitrector gauge and brand. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.