14 November 2022 in IEEE Access
This work presents a free-breathing dynamic contrast-enhanced (DCE) MRI reconstruction method called low-rank plus sparse (L+S) with joint sparsity. The proposed method improved dynamic contrast performance by integrating an additional temporal Fast Fourier Transform (FFT) constraint into the standard L+S decomposition method. In the proposed method, both temporal total variation (TV) sparsity constraint and temporal FFT constraint are integrated into a standard L+S decomposition model, forming L+S with joint sparsity. Temporal TV and Temporal FFT aim to suppress under-sampling artifacts and improve dynamic contrast in DCE-MRI, respectively. A fast composite splitting algorithm (FCSA) is adopted for solving the L+S model with multiple sparsity constraints, maintaining the reconstruction efficiency. A computer simulation framework was developed to compare the performance of L+S with joint sparsity and other reconstruction schemes. The performance of L+S with joint sparsity was tested using computer simulation and several liver DCE-MRI datasets. The proposed L+S based method achieved around four times faster reconstruction speed than the GRASP method. With the support of an additional sparsity constraint, the peak DCE signal in the proposed method was increased by more than 20% over that of a standard L+S decomposition.
25 December 2024 in IEEE Access
This paper introduces a motion-corrected, free-breathing dynamic contrast-enhanced (DCE) MRI reconstruction method, termed low-rank plus sparse (L+S) with soft weighting. We designed a soft weighting matrix that smoothly transitions spokes between the target and other motion states to suppress motion blurring. The optimized fast iterative shrinkage-thresholding algorithm (FISTA) was employed to solve the L+S optimization problem, enabling faster convergence and better image quality. A DCE-MRI computer simulation framework, based on a modified Shepp-Logan model, was used as ground truth to quantify the motion suppression errors. Both simulation and clinical datasets demonstrate that the proposed method provides superior motion correction and higher reconstruction efficiency compared to existing motion-corrected GRASP frameworks.
1 January 2026 in IEEE Transactions on Instrumentation and Measurement
22 December 2025 in IEEE Access
Lung function can be investigated by OE-MRI via alternation between room air and pure oxygen during a dynamic ventilation process, where oxygen wash-in time has been reported to relate to various diseases. This study investigates the feasibility of a free-breathing 3D dynamic oxygen-enhanced MRI (OE-MRI) technique using a golden-angle stack-of-stars ultra-short echo time (UTE) sequence with sliding-window reconstruction for whole-lung functional assessment. The continuous acquisition model was used to capture both steady states and the gas-switching process. Images along the time dimension were reconstructed using the sliding window technique. Comparative analysis with the traditional IR-HASTE sequence revealed significantly longer wash-in times with the UTE-based approach, which may reflect either enhanced sensitivity to oxygen delivery dynamics or potential confounding effects from the sliding-window reconstruction’s temporal smoothing. Despite this methodological consideration, the regional distribution of wash-in times showed reasonable agreement with percent signal enhancement maps, supporting the technique’s feasibility. While promising as a technical framework for 3D dynamic lung imaging, the study highlights important considerations regarding reconstruction algorithms in quantitative OE-MRI. Future work should focus on validating these findings in patient populations and exploring alternative reconstruction strategies to better characterize the method’s clinical potential for assessing pulmonary function.