Brynn E. Marks

Brynn E. Marks

Auto-generated profile, based on publicly available information

Brynn E. Marks

Division of Endocrinology and Diabetes, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2021 in Hormone Research in Paediatrics
Verified
Journal Article
Open access
PDF file
BMBrynn E. Marks
Brynn E. Marks
AKAneka Khilnani
Aneka Khilnani
AMAbby Meyers
Abby Meyers
MFMyrto E. Flokas
Myrto E. Flokas
JGJiaxiang Gai
Jiaxiang Gai
EEElizabeth Estrada
Elizabeth Estrada
Introduction: The impact of the COVID-19 pandemic on the incidence of pediatric type 1 (T1D) and type 2 diabetes (T2D) and severity of presentation at diagnosis is unclear. Methods: A retrospective comparison of 737 youth diagnosed with T1D and T2D during the initial 12 months of the COVID-19 pandemic and in the preceding 2 years was conducted at a pediatric tertiary care center. Results: Incident cases of T1D rose from 152 to 158 in the 2 years before the pandemic (3.9% increase) to 182 cases during the pandemic (15.2% increase). The prevalence of diabetic ketoacidosis (DKA) at T1D diagnosis increased over 3 years (41.4%, 51.9%, and 57.7%, p = 0.003); severe DKA increased during the pandemic as compared to the 2 years before (16.8% vs. 28%, p = 0.004). Although there was no difference in the mean hemoglobin A1c (HbA1c) between racial and ethnic groups at T1D diagnosis in the 2-years pre-pandemic (p = 0.31), during the pandemic HbA1c at T1D diagnosis was higher in non-Hispanic Black (NHB) youth (11.3 ± 1.4%, non-Hispanic White 10.5 ± 1.6%, Latinx 10.8 ± 1.5%, p = 0.01). Incident cases of T2D decreased from 54 to 50 cases (7.4% decrease) over the 2-years pre-pandemic and increased 182% during the pandemic (n = 141, 1.45 cases/month, p < 0.001). As compared to the 2-years pre-pandemic, cases increased most among NHB youth (56.7% vs. 76.6%, p = 0.001) and males (40.4% vs. 58.9%, p = 0.005). Cases of DKA (5.8% vs. 23.4%, p < 0.001) and hyperosmolar DKA (0 vs. 9.2%, p = 0.001) increased among youth with T2D during the pandemic. Conclusions: During the pandemic, the incidence and severity of presentation of T1D increased modestly, while incident cases of T2D increased 182%, with a nearly 6-fold increase in DKA and nearly a 10% incidence of hyperosmolar DKA. NHB youth were disproportionately impacted, raising concern about worsening of pre-existing health disparities during and after the pandemic.

17 March 2020 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
BMBrynn E. Marks
Brynn E. Marks
JWJoseph I. Wolfsdorf
Joseph I. Wolfsdorf
Regular self-monitoring of blood glucose levels, and ketones when indicated, is an essential component of type 1 diabetes (T1D) management. Although fingerstick blood glucose monitoring has been the standard of care for decades, ongoing rapid technological developments have resulted in increasingly widespread use of continuous glucose monitoring (CGM). This article reviews recommendations for self-monitoring of glucose and ketones in pediatric T1D with particular emphasis on CGM and factors that impact the accuracy and real-world use of this technology.

7 November 2023 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
BMBrynn E. Marks
Brynn E. Marks
SMSeema Meighan
Seema Meighan
AZAnum Zehra
Anum Zehra
JDJulia L. Douvas
Julia L. Douvas
ARAndrew Rearson
Andrew Rearson
RWRisa M Wolf
Risa M Wolf
Background: Pivotal trials of diabetes technologies have demonstrated glycemic improvements; however, these trials include patients of limited diversity and ranges of glycemic control. We assessed changes in glycemic control during the first 90 days of Omnipod 5 use in a real-world cohort of youth with type 1 diabetes (T1D). Methods: Youth 2–21 years with T1D initiating Omnipod 5 at two pediatric academic centers were included. Fourteen days of baseline (BL) continuous glucose monitoring (CGM) data were compared against data from the first 90 days of Omnipod 5 use. Outcome measures included changes in time in range (TIR), hemoglobin A1c (HbA1c), and CGM and insulin pump metrics based on the duration of Omnipod 5 use. Results: Among 195 youth (78.9% non-Hispanic White, 15.4% publicly insured, age 11.7 years, T1D duration 3.3 years) TIR increased 11%-points, from 49% to 61% ( P < 0.001), and HbA1c decreased 0.5%-points, from 7.5% to 6.9% ( P < 0.001). TIR improved within the first 9 days of Omnipod 5 use ( p < 0.001) and did not change significantly thereafter ( P = 0.1) despite decreases in user-initiated boluses (5.1 vs. 5.0, P = 0.01) and carbohydrate entries (4.2 vs. 4.1, P = 0.005) from days 1–9 to days 1–90. TIR improved 15%-points among youth with BL TIR <60% compared to a 5%-point increase for youth with BL TIR ≥60% ( P < 0.001). Conclusions: Glycemic control improved within 9 days of Omnipod 5 initiation in this real-world cohort, and improvements were sustained over the first 90 days of use despite concomitant decreases in user-initiated boluses. These improvements were comparable to those observed in the pivotal trial.

4 December 2021 in Journal of Clinical & Translational Endocrinology
Verified
Journal Article
Open access
BMBrynn E. Marks
Brynn E. Marks
KWKristen M. Williams
Kristen M. Williams
JSJordan S. Sherwood
Jordan S. Sherwood
MPMelissa S. Putman
Melissa S. Putman
• Individuals with CFRD have unique diabetes physiology and comorbidities. • Perceptions of diabetes technology use in the CF community are positive. • Limited evidence supports the clinical effectiveness of these technologies in CFRD. • Automated insulin delivery improves A1c and decreases patient burden in T1D. • Proof of benefits to device use in CFRD may improve insurance coverage and increase sustained use.

2 October 2008 in Behavioural Brain Research
Verified
Journal Article
Closed access
SSSunbin Song
Sunbin Song
BMBrynn Marks
Brynn Marks
JHJames H. Howard
James H. Howard
DHDarlene V. Howard
Darlene V. Howard

1 March 2019 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
BMBrynn E. Marks
Brynn E. Marks
JWJoseph I. Wolfsdorf
Joseph I. Wolfsdorf
GWGretchen Waldman
Gretchen Waldman
DSDiane E. Stafford
Diane E. Stafford
KGKatharine C. Garvey
Katharine C. Garvey
Background: Recent data demonstrating a lack of improvement in average hemoglobin A1c levels despite the increased use of insulin pumps and continuous glucose monitors (CGMs) suggest that patients are not using these technologies optimally. Suboptimal provider understanding of these devices may be a contributing factor. Methods: We sought to assess fellows' knowledge, attitudes, and practices regarding insulin pumps and CGMs using a mixed-methods survey. We polled 42 pediatric endocrinology fellows and 69 attending physicians in pediatric endocrinology using items on a five-point Likert scale. Results: Perceived fellow knowledge of insulin pumps and CGMs was only 3.6 ± 1.0 and 3.6 ± 0.9, respectively. Despite consensus about the need for pediatric endocrinologists to understand these technologies, only 14.7% of fellows reported the presence of a formal curriculum about these technologies at their institutions. Potential gaps identified in fellows' knowledge include general use and troubleshooting, advanced insulin pump features, infusion sets and dermatological complications, systematic approach to data, interpretation and application of CGM data, and keeping pace with technological advances. Conclusions: Our data suggest suboptimal fellow knowledge and understanding of insulin pumps and CGMs in pediatric type 1 diabetes management, which is likely attributable to inadequate education in fellowship training programs. The development of formal educational curricula targeting areas of weakness identified in this survey may improve clinician knowledge of these technologies and ultimately impact patient education and care.