Juan Cheng

Juan Cheng

Auto-generated profile, based on publicly available information

Juan Cheng

Department of Ultrasound, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2025 in Ultrasonography
Verified
Journal Article
Open access
PDF file
YHYun-Lin Huang
Yun-Lin Huang
CSChao Sun
Chao Sun
YDYi Dong
Yi Dong
JCJuan Cheng
Juan Cheng
SWShi-Wen Wang
Shi-Wen Wang
Yi DongYi Dong
Yi Dong
Purpose: This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.Methods: Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.Results: Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).Conclusion: Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.

12 January 2023 in Frontiers in Public Health
Verified
Journal Article
Open access
WZWeijie Zhong
Weijie Zhong
XYXiaosheng Yang
Xiaosheng Yang
XJXiufeng Jiang
Xiufeng Jiang
ZDZhixin Duan
Zhixin Duan
WWWei Wang
Wei Wang
YLYI LI
YI LI
Background: This study explores the risk factors associated with viral shedding time in elderly Chinese patients infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) omicron.Methods: Participants infected with SARS-CoV-2 omicron were enrolled in a retrospective study, and divided into two groups according to shedding time (≥10 days, “late clearance group” and <10 days, “early clearance group”).Results: A total of 180 patients were enrolled in the study (88 early, 92 late), with a median viral shedding time of 10 days and a mean age of 77.02 years. Prolonged SARS-CoV-2 omicron shedding was associated with old age (p = 0.007), lack of vaccination (p = 0.001), delayed admission to hospital after onset of diagnosis (p = 0.001), D-dimer (p = 0.003), and methylprednisolone treatment (p = 0.048). In multivariate analysis, vaccination (OR, 0.319, 95% CI, 0.130–0.786, p = 0.013), Paxlovid (OR, 0.259, 95% CI, 0.104–0.643, p = 0.004), and time from onset of diagnosis to admission (OR, 1.802, 95% CI, 1.391–2.355, p = 0.000) were significantly associated with viral clearance.Conclusions: Time from onset of diagnosis to hospitalization, lack of treatment with Paxlovid, and lack of vaccination were independent risk factors in elderly Chinese patients infected with SARS-CoV-2 omicron for prolonged viral shedding.

31 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YQYi-Jie Qiu
Yi-Jie Qiu
JCJuan Cheng
Juan Cheng
QZQi Zhang
Qi Zhang
DYDao-Hui Yang
Dao-Hui Yang
DZDan Zuo
Dan Zuo
WWWen-Ping Wang
Wen-Ping Wang
Objective: This study seeks to evaluate the value of the high-frame-rate vector flow imaging technique in assessing the hemodynamic changes of carotid atherosclerotic stenosis in aging people (>60 years old). Methods: Aging patients diagnosed with carotid atherosclerotic stenosis who underwent carotid high-frame-rate vector flow imaging examination were prospectively enrolled. A Mindray Resona7s ultrasound machine equipped with high-frame-rate vector flow function was used for ultrasound evaluation. First, B mode ultrasound and color Doppler flow imaging were used to evaluate carotid stenosis. Then, the vector arrows and flow streamline detected by V Flow were analyzed and the wall shear stress values (Pa) at the carotid stenosis site were measured. All patients were divided into symptomatic and asymptomatic groups according to whether they had acute/subacute stroke or other clinical symptoms within 2 weeks before ultrasound examination. The results of digital subtraction angiography or computed tomography angiography were used as the gold standard. The stenosis rate was calcified, according to North American Symptomatic Carotid Endarterectomy Trial criteria. The diagnostic values of wall shear stress, conventional ultrasound, and the combined diagnosis in carotid atherosclerotic stenosis were compared. Results: Finally, 88 patients with carotid atherosclerotic plaque were enrolled (71 males (80.7%), mean age 67.6 ± 5.4 years). The success rate of high-frame-rate vector flow imaging was 96.7% (88/91). The WSS value of symptomatic carotid stenosis (1.4 ± 0.15 Pa) was significantly higher than that of asymptomatic carotid stenosis (0.80 ± 0.08 Pa) (p < 0.05). Taking the wall shear stress value > 0.78 Pa as the diagnostic criteria for symptomatic carotid atherosclerotic plaque, the area under receiver operating characteristic curves was 0.79 with 87.1% sensitivity and 69.6% specificity. The area under receiver operating characteristic curves of the combined diagnosis (0.966) for differentiating severe carotid atherosclerotic stenosis was significantly higher than that of conventional ultrasound and WSS value, with 89.7% sensitivity and 93.2% specificity (p < 0.05). Conclusion: As a non-invasive imaging method, the high-frame-rate vector flow imaging technique showed potential value in the preoperative assessment of the symptomatic carotid atherosclerotic stenosis and diagnosing carotid atherosclerotic stenosis in aging patients.

1 March 2016 in Behavioural Brain Research
Verified
Journal Article
Closed access
YLY. Li
Y. Li
WMW.W. Mao
W.W. Mao
CZC.G. Zhang
C.G. Zhang
LWL. Wan
L. Wan
CJC.H. Jing
C.H. Jing
JCJ. Cheng
J. Cheng

9 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
DYDao-Hui Yang
Dao-Hui Yang
JCJuan Cheng
Juan Cheng
XTXiao-Fan Tian
Xiao-Fan Tian
QZQi Zhang
Qi Zhang
LYLing-Yun Yu
Ling-Yun Yu
WWWen-Ping Wang
Wen-Ping Wang
Objective: To investigate whether the dynamic contrast-enhanced ultrasound (DCE-US) analysis and quantitative parameters could be helpful for predicting histopathologic grades of pancreatic neuroendocrine tumors (pNETs). Methods: This retrospective study conducted a comprehensive review of the CEUS database between March 2017 and November 2021 in Zhongshan Hospital, Fudan University. Ultrasound examinations were performed by an ACUSON Sequioa unit equipped with a 3.5 MHz 6C−1 convex array transducer, and an ACUSON OXANA2 unit equipped with a 3.5 MHz 5C−1 convex array transducer. SonoVue® (Bracco Inc., Milan, Italy) was used for all CEUS examinations. Time intensity curves (TICs) and quantitative parameters of DCE-US were created by Vuebox® software (Bracco, Italy). Inclusion criteria were: patients with histopathologically proved pNETs, patients who underwent pancreatic B-mode ultrasounds (BMUS) and CEUS scans one week before surgery or biopsy and had DCE-US imaging documented for more than 2 min, patients with solid or predominantly solid lesions and patients with definite diagnosis of histopathological grades of pNETs. Based on their prognosis, patients were categorized into two groups: pNETs G1/G2 group and pNETs G3/pNECs group. Results: A total of 42 patients who underwent surgery (n = 38) or biopsy (n = 4) and had histopathologically confirmed pNETs were included. According to the WHO 2019 criteria, all pNETs were classified into grade 1 (G1, n = 10), grade 2 (G2, n = 21), or grade 3 (G3)/pancreatic neuroendocrine carcinomas (pNECs) (n = 11), based on the Ki−67 proliferation index and the mitotic activity. The majority of the TICs (27/31) of pNETs G1/G2 were above or equal to those of pancreatic parenchyma in the arterial phase, but most (7/11) pNETs G3/pNECs had TICs below those of pancreatic parenchyma from arterial phase to late phase (p < 0.05). Among all the CEUS quantitative parameters of DCE-US, values of relative rise time (rPE), relative mean transit time (rmTT) and relative area under the curve (rAUC) were significantly higher in pNETs G1/G2 group than those in pNETs G3/pNECs group (p < 0.05). Taking an rPE below 1.09 as the optimal cut-off value, the sensitivity, specificity and accuracy for prediction of pNETs G3/pNECs from G1/G2 were 90.91% [58.70% to 99.80%], 67.64% [48.61% to 83.32%] and 85.78% [74.14% to 97.42%], respectively. Taking rAUC below 0.855 as the optimal cut-off value, the sensitivity, specificity and accuracy for prediction of pNETs G3/pNECs from G1/G2 were 90.91% [66.26% to 99.53%], 83.87% [67.37% to 92.91%] and 94.72% [88.30% to 100.00%], respectively. Conclusions: Dynamic contrast-enhanced ultrasound analysis might be helpful for predicting the pathological grades of pNETs. Among all quantitative parameters, rPE, rmTT and rAUC are potentially useful parameters for predicting G3/pNECs with aggressive behavior.

1 May 2025 in Ultrasonography
Verified
Journal Article
Open access
PDF file
Yi DongYi Dong
Yi Dong
JCJuan Cheng
Juan Cheng
YHYun-Lin Huang
Yun-Lin Huang
YQYi-Jie Qiu
Yi-Jie Qiu
JCJia-Ying Cao
Jia-Ying Cao
CDChristoph Frank Dietrich
Christoph Frank Dietrich
Purpose: This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).Methods: In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.Results: From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.Conclusion: Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.