Baiq Sri Umniati

Baiq Sri Umniati

Auto-generated profile, based on publicly available information

Baiq Sri Umniati

Department of Civil Engineering, Faculty of Engineering, State University of Malang, Malang, Indonesia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
BUB. Sri Umniati
B. Sri Umniati
PRPuput Risdanareni
Puput Risdanareni
FZFahmi Tarmizi Zulfikar Zein
Fahmi Tarmizi Zulfikar Zein
Geopolymer concrete is a type of concrete manufactured without the addition of cement. In geopolymer concrete, along with an activator, cement as the concrete binder can be replaced by the fly ash. This will reduce global demand on cement, and therefore will reduce CO2 emission due to cement production. Thus, geopolymer concrete is commonly known as an eco-friendly concrete. Geopolymer concrete also offers a solution concerning with the utilization of the fly ash waste. However, despite of its environmental advantages, geopolymer concrete has a drawback, namelygeopolymer concrete set quickly, thus reducing its workability. This research aimed to increase the workability of geopolymer concrete by using retarder admixture (Plastocrete RT6 Plus). Retarder used varies within 0.2%, 0.4% and 0.6% of fly ash mass. As a control, geopolymer concrete without retarder (0%) were also made. Activator used in this research was Na2SiO3 mixed with NaOH 10 M solution, with ratio of 1:5. The results showed an optimum composition of geopolymer concrete with 0.6% retarder, where initial setting time occured after 6.75 hours, and the final setting time reached after 9.5 hours. Moreover, the slump of the geopolymer concrete was 8.8 cm, and the slump flow was 24 cm. The compressive strength of the geopolymer concrete at 28 days was 47.21 MPa. The experiment showed that the more retarder added, the setting time of the geopolymer concrete will be increased, thus increasing its workability.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
MPM. Mirza Abdillah Pratama
M. Mirza Abdillah Pratama
AHAy Lie Han
Ay Lie Han
BGBuntara Sthenly Gan
Buntara Sthenly Gan
BUB. Sri Umniati
B. Sri Umniati
PRPuput Risdanareni
Puput Risdanareni
SFShifa Fauziyah
Shifa Fauziyah
Concrete casting, compacting method, and characteristic of the concrete material determine the performance of concrete as building element due to the material uniformity issue. Previous studies show that gradation in strength exists on building member by nature and negatively influence the load carrying capacity of the member. A pilot research had modeled the concrete gradation in strength with controllable variable and observed that the weakest material determines the strength of graded concrete through uniaxial compressive loading test. This research intends to confirm the recent finding by a numerical approach with extensive variables of strength disparity. The finite element analysis was conducted using the Strand7 nonlinear program. The results displayed that the increase of strength disparity in graded concrete models leads to the slight reduction of models strength. A substantial difference in displacement response is encountered on the models for the small disparity of concrete strength. However, the higher strength of concrete mix in the graded concrete models contributes to the rise of material stiffness that provides a beneficial purpose for serviceability of building members.

1 February 2017 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
NNNindyawati Nindyawati
Nindyawati Nindyawati
BUB. Sri Umniati
B. Sri Umniati
PRPuput Risdanareni
Puput Risdanareni
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry

2 March 2026 in Discover Concrete and Cement
Verified
Journal Article
Open access
PDF file
AAALIYU AHMED AZARE
ALIYU AHMED AZARE
MIMohd Haziman Wan Ibrahim
Mohd Haziman Wan Ibrahim
SMSajjad Ali Mangi
Sajjad Ali Mangi
BUBaiq. Sri Umniati
Baiq. Sri Umniati
RJRamadhansyah Putra Jaya
Ramadhansyah Putra Jaya
Concrete structures susceptible to early deterioration through chemical attack, microstructural disruption, and degradation of strength are those exposed to sulfate, chloride, and acidic groundwater. Specimens (concrete) were exposed to determine the resistance of concrete to these chemicals, and were also partially replaced with silica fume and fly ash at a weight equivalent to the cement, in order to determine the optimum percentage of replacement. Although the addition of supplementary cementitious materials (SCMs), such as silica fume (SF) and fly ash (FA), is considered to enhance durability, the literature on the subject has been limited to single exposure environments, standard Portland cement systems, or long-term performance. High-strength self-compacting concrete (HSSCC) using ternary combinations of SF and FA in various aggressive exposure conditions and acidic groundwater has not been adequately studied in terms of its short-term durability response. The study gives a comparative experimental research of the short-term durability performance (28–90 days) of ternary blended HSSCC when exposed to sulfate, chloride, and acidic groundwater. The variation in compressive strength, change in mass, and damage indices were used to evaluate the durability performance and assess the sensitivity of degradation under varying chemical media. The findings suggest that the integrated use of SF and FA has a substantial positive impact on early-age resistance to chemical attack, due to the refinement of the pore structure, restriction of aggressive ion penetration, and reduction of strength loss compared to the control mix. The synergistic effect of the fast microfilling and pozzolanic activity of SF, combined with the slow, prolonged pozzolanic reaction of FA, has a significant impact on enhancing early durability in an aggressive environment. This research provides insight into the understanding of early-age degradation mechanisms of ternary blended HSSCC and offers a performance-based framework for understanding long-lasting operation in chemically aggressive groundwater and industrial conditions.

1 February 2017 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
BUB. Sri Umniati
B. Sri Umniati
SDSri Murni Dewi
Sri Murni Dewi
NNNindyawati Nindyawati
Nindyawati Nindyawati
GSGatot Adi Susilo
Gatot Adi Susilo
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry

6 January 2025 in BENTANG : Jurnal Teoritis dan Terapan Bidang Rekayasa Sipil
Verified
Journal Article
Open access
PDF file
AMAndra Akmal Maulidani
Andra Akmal Maulidani
MSMohammad Sulton
Mohammad Sulton
BUB. Sri Umniati
B. Sri Umniati
AMAlfia Salma Mei Maulida
Alfia Salma Mei Maulida
Indonesia's location in an earthquake zone with moderate to high intensity increases the urgency of planning high-rise earthquake-resistant buildings. Losses that occur due to the absence of procedures to predict earthquakes properly and accurately, make it important to innovate structural systems and evaluate their performance against earthquakes. This study aims to determine the impact of adding Tuned Mass Damper to buildings viewed from the level of structural performance compared to Fixed Base structures. Performance Base Design based on FEMA 440, is a design that categorizes the target damage to building structures into 4 levels of damage reviewed from the percentage of story deviation to the total height of the structure. Tuned Mass Damper is an innovation in structural systems consisting of mass, springs, and dampers installed to absorb their dynamic response. Pendulum Tuned Mass Damper is a Tuned Mass Damper system using a pendulum swinging relative to the floor motion. The addition of Tuned Mass Damper to Fixed Base type buildings causes a decrease in deviation of up to 19% from the original deviation depending on the mass ratio. This addition also reduces the value of the structural period by up to 9% with the period still below the maximum period standard. In addition, the addition of Tuned Mass Damper also reduces the target value of structural displacement based on FEMA 440 by 52% with the immediate occupancy building performance level.