Nathalia Cancino-Fuentes

Nathalia Cancino-Fuentes

Auto-generated profile, based on publicly available information

Nathalia Cancino-Fuentes

Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS) Barcelona Spain

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2023 in Nanoscale
Verified
Journal Article
Open access
PDF file
NCNathalia Cancino-Fuentes
Nathalia Cancino-Fuentes
AMArnau Manasanch
Arnau Manasanch
JCJoana Covelo
Joana Covelo
ASAlex Suarez-Perez
Alex Suarez-Perez
EFEnrique Fernandez
Enrique Fernandez
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives
Full-band recordings, including infraslow components, were obtained with graphene SGFETs from cerebral cortex slices. First gSGFETs recordings from human tissue in vitro were obtained. gSGFETs were also used to quantify both exogenous and endogenous electric fields.

31 July 2026 in Advanced Science
Verified
Journal Article
Open access
PDF file
NCNathalia Cancino‐Fuentes
Nathalia Cancino‐Fuentes
ASAlejandro Suarez‐Perez
Alejandro Suarez‐Perez
EZElric Zhang
Elric Zhang
HYHao Ye
Hao Ye
Marta BonatoMarta Bonato
Marta Bonato
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives
Achieving precise and minimally invasive control of brain activity remains a major challenge in neuroscience, with current non‐invasive techniques offering limited spatial and temporal resolution. Here, this study investigated whether magnetoelectric nanoparticles (MENPs) can extend the effective neuromodulation range of static magnetic fields, enabling modulation under intensities (<100 mT) that are otherwise biologically inert. To this end, MENPs comprising a cobalt ferrite magnetostrictive core and a piezoelectric barium titanate shell were fabricated. Using magnetoelectric modeling, the non‐negligible electric fields generated by individual MENPs under magnetic‐field strengths used experimentally were estimated. The ability of MENPs to modulate cortical network activity in spontaneously rhythmic cortical slices under low‐intensity static magnetic fields was tested. Using electrophysiological recordings, network activity was directly measured before, during, and after stimulation. Magnetic fields alone did not alter neuronal activity at the intensities used. In contrast, in the presence of MENPs, the same fields activated the network, enhancing the frequency of spontaneous rhythmic activity and thus network excitability. These findings demonstrate that MENPs lower the threshold for magnetic neuromodulation, providing a mechanistic link between weak magnetic inputs and network‐level brain activity. This work position MENPs as a promising strategy for the wireless modulation of neuronal network dynamics, with the potential to reach deep brain circuits.

10 September 2026 in Advanced Science
Verified
Journal Article
Open access
PDF file
Marta BonatoMarta Bonato
Marta Bonato
EZElric Zhang
Elric Zhang
Emma ChiaramelloEmma Chiaramello
Emma Chiaramello
Serena FiocchiSerena Fiocchi
Serena Fiocchi
Giulia SuaratoGiulia Suarato
Giulia Suarato
Marta ParazziniMarta Parazzini
Marta Parazzini
Magnetoelectric nanoparticles (MENPs) represent a promising approach for wireless, minimally invasive neuromodulation with submillimetre precision. This study presents a multi‐scale computational framework that bridges the gap from single‐nanoparticle magnetoelectric properties to tissue‐level electric field distributions, establishing a digital twin approach adaptable to different experimental platforms. The framework operates across three interconnected levels. (1). At the nanoscale, a 2D axisymmetric COMSOL model characterizes individual MENP response, integrating experimental data from cobalt ferrite cores (15–20 nm diameter) with barium titanate shells. Parametric analysis reveals that larger cores generate higher electric potentials due to increased magnetostrictive volume. (2). At the in vitro level, electromagnetic simulations replicate the experimental setup as a digital twin, establishing baseline field distributions and confirming that coil‐induced electric fields alone remain below neuromodulation thresholds. (3). At the tissue scale, a dipole‐based approach models collective MENP behavior at physiologically relevant concentrations (0.1% and 0.2% w/v). Results demonstrate that MENPs generate widespread electric fields exceeding 10 V/m (77%–92% tissue coverage) with localized hotspots surpassing 100 V/m, intensities sufficient for neural modulation and activation. The framework provides quantitative predictions for optimizing nanoparticle design and stimulation parameters, supporting the rational development of MENP‐based neuromodulation strategies.

13 September 2024
Verified
Conference Paper
Open access
SMStratis Matsoukis
Stratis Matsoukis
JSJosef Scharinger
Josef Scharinger
JCJoana Covelo
Joana Covelo
NCNathalia Cancino-Fuentes
Nathalia Cancino-Fuentes
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives
CGChristoph Guger
Christoph Guger
Recent research has focused on brain stimulation using low-intensity electric and magnetic fields. This study presents a multifunctional software platform developed with .NET MAUI for low-intensity magnetic field neural stimulation. The platform provides waveform synthesis, protocol programming, and feedback integration for versatile use in experiments. Users can create complex protocols, monitor key parameters, and receive real-time feedback. Performance testing with various hardware components validated the platform's ability to generate waveforms and accurately measure operational parameters, increasing experimental flexibility and potential medical applications.