Time-dependent forces applied by 2 and 4.5 mm diameter drops of water (with velocities up to terminal velocity) impacting upon a glass plate with or without a water layer (up to 10 mm depth) have been measured using two different approaches, force transduction and wavelet deconvolution. Both approaches are in close agreement for drops falling on dry glass. However, only the wavelet approach is able to measure natural features of the splash on shallow water layers that impart forces to the plate after the initial impact. At relatively high velocities (including terminal velocity) the measured peak force from the initial impact is significantly higher than that predicted by idealised drop shape models and models from Roisman et al. and Marengo et al. Hence empirical formulae are developed for the initial time-dependent impact force from drops falling at (a) different velocities up to and including terminal velocity onto a dry glass surface, (b) terminal velocity onto dry glass or glass with a water layer and (c) different velocities below terminal velocity onto dry glass or glass with a water layer. For drops on dry glass, the empirical formulae are applicable to a glass plate or a composite layered plate with a glass surface, although they apply to other plate thicknesses and are applicable to any plate material with a similar surface roughness and wettability. The measurements also indicate that after the initial impact there can be high level forces when bubbles are entrained in the water layer.
Externally generated visual motion signals can cause the illusion of self-motion in space (vection) and corresponding visually evoked postural responses (VEPR). These VEPRs are not simple responses to optokinetic stimulation, but are modulated by the configuration of the environment. The aim of this paper is to explore what factors modulate VEPRs in a high quality virtual reality (VR) environment where real and virtual foreground objects served as static visual, auditory and haptic reference points. Data from four experiments on visually evoked postural responses show that: 1) visually evoked postural sway in the lateral direction is modulated by the presence of static anchor points that can be haptic, visual and auditory reference signals; 2) real objects and their matching virtual reality representations as visual anchors have different effects on postural sway; 3) visual motion in the anterior-posterior plane induces robust postural responses that are not modulated by the presence of reference signals or the reality of objects that can serve as visual anchors in the scene. We conclude that automatic postural responses for laterally moving visual stimuli are strongly influenced by the configuration and interpretation of the environment and draw on multisensory representations. Different postural responses were observed for real and virtual visual reference objects. On the basis that automatic visually evoked postural responses in high fidelity virtual environments should mimic those seen in real situations we propose to use the observed effect as a robust objective test for presence and fidelity in VR.
Presentation of music as vibration to the skin has the potential to facilitate interaction between musicians with hearing impairments and other musicians during group performance. Vibrotactile thresholds have been determined to assess the potential for vibrotactile presentation of music to the glabrous skin of the fingertip, forefoot and heel. No significant differences were found between the thresholds for sinusoids representing notes between C1 and C6 when presented to the fingertip of participants with normal hearing and with a severe or profound hearing loss. For participants with normal hearing, thresholds for notes between C1 and C6 showed the characteristic U-shape curve for the fingertip, but not for the forefoot and heel. Compared to the fingertip, the forefoot had lower thresholds between C1 and C3, and the heel had lower thresholds between C1 and G2; this is attributed to spatial summation from the Pacinian receptors over the larger contactor area used for the forefoot and heel. Participants with normal hearing assessed the perception of high-frequency vibration using 1s sinusoids presented to the fingertip and were found to be more aware of transient vibration at the beginning and/or end of notes between G4 and C6 when stimuli were presented 10dB above threshold, rather than at threshold. An average of 94% of these participants reported feeling continuous vibration between G4 and G5 with stimuli presented 10dB above threshold. Based on the experimental findings and consideration of health effects relating to vibration exposure, a suitable range of notes for vibrotactile presentation of music is identified as being from C1 to G5. This is more limited than for human hearing but the fundamental frequencies of the human voice, and the notes played by many instruments, lie within it. However, the dynamic range might require compression to avoid the negative effects of amplitude on pitch perception.
This study investigated the perception and learning of relative pitch using vibrotactile stimuli by musicians with and without a hearing impairment. Notes from C3 to B4 were presented to the fingertip and forefoot. Pre- and post-training tests in which 420 pairs of notes were presented randomly were carried out without any feedback to participants. After the pre-training test, 16 short training sessions were carried out over six weeks with 72 pairs of notes per session and participants told whether their answers were correct. For amateur and professional musicians with normal hearing and professional musicians with a severe or profound hearing loss, larger pitch intervals were easier to identify correctly than smaller intervals. Musicians with normal hearing had a high success rate for relative pitch discrimination as shown by pre- and post-training tests, and when using the fingertips, there was no significant difference between amateur and professional musicians. After training, median scores on the tests in which stimuli were presented to the fingertip and forefoot were >70% for intervals of 3–12 semitones. Training sessions reduced the variability in the responses of amateur and professional musicians with normal hearing and improved their overall ability. There was no significant difference between the relative pitch discrimination abilities between one and 11 semitones, as shown by the pre-training test, of professional musicians with and without a severe/profound hearing loss. These findings indicate that there is potential for vibration to be used to facilitate group musical performance and music education in schools for the deaf.