This paper presents a comparison between Field-Oriented Control (FOC) and Conventional Direct Torque Control (CDTC) strategies for Permanent Magnet Synchronous Motors (PMSMs) in electric vehicle (EV) applications, with both approaches employing the Maximum Torque per Ampere (MTPA) technique. The FOC method decouples torque and flux by independently regulating the $d-q$ axis currents, whereas CDTC directly controls torque and stator flux using hysteresis controllers and a switching table. The performance metrics evaluated are the average torque per RMS current, torque ripple, flux ripple, and total harmonic distortion of the phase current. A vehicle-cycle condition is also simulated. Results show that FOC achieves superior performance across all metrics, delivering smoother operation and improved current utilization, especially at low speeds, while CDTC exhibits more irregular responses with higher ripple and distortion. These findings reinforce the suitability of FOC for EV, where higher efficiency directly translates into extended driving range.