Serkan Inceoglu

Serkan Inceoglu

Auto-generated profile, based on publicly available information

Serkan Inceoglu

Department of Orthopedic Surgery, Loma Linda University, Loma Linda, California

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in Spine
Verified
Journal Article
Closed access
DBDaniel J. Burval
Daniel J. Burval
RMRobert F. McLain
Robert F. McLain
RMRyan Milks
Ryan Milks
SISerkan Inceoglu
Serkan Inceoglu
Pedicle screw pullout testing in osteoporotic and control human cadaveric vertebrae, comparing augmented and control vertebrae. To compare the pullout strengths of pedicle screws fixed in osteoporotic vertebrae using polymethyl methacrylate delivered by 2 augmentation techniques, a standard transpedicular approach and kyphoplasty type approach. Pedicle screw instrumentation of the osteoporotic spine carries an increased risk of screw loosening, pullout, and fixation failure. Osteoporosis is often cited as a contraindication for pedicle screw fixation. Augmentation of the vertebral pedicle and body using polymethyl methacrylate may improve fixation strength and construct survival in the osteoporotic vertebrae. While the utility of polymethyl methacrylate has been demonstrated for salvage of screws that have been pulled out, the effect of the cement technique on pullout strength in osteoporotic vertebrae has not been previously studied. Thirteen osteoporotic and 9 healthy human lumbar vertebrae were tested. All specimens were instrumented with pedicle screws using a uniform technique. Osteoporotic pedicles were augmented with polymethyl methacrylate using either a kyphoplasty type technique or a transpedicular augmentation technique. Screws were tested in a paired testing array, randomly assigning the augmentation techniques to opposite sides of each vertebra. Pullout to failure was performed either primarily or after a 5000-cycle tangential fatigue conditioning exposure. After testing, following screw removal, specimens were cut in the axial plane through the center of the vertebral body to inspect the cement distribution. Pedicle screws placed in osteoporotic vertebrae had higher pullout loads when augmented with the kyphoplasty technique compared to transpedicular augmentation (1414 +/- 338 versus 756 +/- 300 N, respectively; P < 0.001). An unpaired t test showed that fatigued pedicle screws in osteoporotic vertebrae augmented by kyphoplasty showed higher pullout resistance than those placed in healthy control vertebrae (P = 0.002). Both kyphoplasty type augmentation (P = 0.007) and transpedicular augmentation (P = 0.02) increased pullout loads compared to pedicle screws placed in nonaugmented osteoporotic vertebrae when tested after fatigue cycling. Pedicle screw augmentation with polymethyl methacrylate improves the initial fixation strength and fatigue strength of instrumentation in osteoporotic vertebrae. Pedicle screws augmented using the kyphoplasty technique had significantly greater pullout strength than those augmented with transpedicular augmentation technique and those placed in healthy control vertebrae with no augmentation.

1 September 2004 in The Spine Journal
Verified
Journal Article
Closed access
SISerkan Inceoglu
Serkan Inceoglu
LFLisa Ferrara
Lisa Ferrara
RMRobert F. McLain
Robert F. McLain

1 May 2011 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
SISerkan İnCeoğlu
Serkan İnCeoğlu
WMWilliam H. Montgomery
William H. Montgomery
SCSelvon St. Clair
Selvon St. Clair
RMRobert F. McLain
Robert F. McLain
Object: Minimally invasive pedicle screws inserted vertically (that is, dorsoventrally) through the pedicle, as opposed to the more common coaxial technique, offer potential advantages by minimizing soft-tissue stripping during screw placement. The screws are designed for insertion through a medial starting point with vertical trajectory through the pedicle and into the vertebral body. As such, no lateral dissection beyond the insertion point is necessary. However, the effects of this insertion technique on the screw biomechanical performance over a short- and long-term are unknown. The authors investigated the pullout strength and stiffness of these screws, with or without fatigue cycling, compared with comparably sized, traditional screws placed by coaxial technique. Methods: Twenty-one lumbar vertebrae (L-3, L-4, and L-5) were tested. Each pedicle of each vertebra was instrumented with either a traditional, coaxial pedicle screw (Group A), placed through a standard starting point, or a vertically oriented, alternative-design screw (Group B), with a medial starting point and vertical trajectory. The specimens were divided into 2 groups for testing. One group was tested for direct pullout (10 specimens) while the other was subject to pullout after tangential (toggle) cyclic loading (11 specimens). The screws were cycled in displacement control (± 5 mm producing ~ 4-Nm moment) at a rate of 3 Hz for 5000 cycles. Pullout tests were performed at a rate of 1 mm/minute. Results: Two-way ANOVA showed that Group B screws with a medial starting point (2541 ± 1090 N for cycled vs 2135 ± 1323 N for noncycled) had significantly higher pullout loads than Group A screws with a standard entry point (1585 ± 766 N for cycled vs 1417 ± 812 N noncycled) (p = 0.001). There was no significant effect of cycling or screw insertion type on pullout stiffness. Tangential stiffness of the Group B screws was significantly less than that of the Group A screws (p = 0.001). The stiffness of both screws in the toe region was significantly affected by cycling (p = 0.001). Conclusions: The use of Group B screws inserted through a medial starting point showed greater pullout load than a Group A screw inserted through a standard starting point. The greater pullout strength in Group B screws may be due to screw thread design and increased cortical bone purchase at the medial starting point. Nevertheless, anatomical considerations of the medial starting point, that is, pedicle or lateral vertebral body cortex breach, may limit its application. The medial starting point of the Group B screw was frequently in the facet at the L-3 and L-4 pedicle entry points, which may have clinical importance.

30 September 2014 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
JHJoseph Minsoo Hahn
Joseph Minsoo Hahn
SISerkan İnCeoğlu
Serkan İnCeoğlu
MWMontri Daniel Wongworawat
Montri Daniel Wongworawat
Background: Common suture configuration techniques used for ligament and tendon grafts and repair are the Krackow locking stitch and a nonlocking loop stitch, such as a whipstitch. Clinically, the preferences of orthopaedic surgeons vary. Hypothesis: The Krackow locking stitch and the nonlocking whipstitch, with varying suture loops, produce different biomechanical and physical effects on the tendon end. Study Design: Controlled laboratory study. Methods: A total of 52 fresh-frozen porcine flexor digitorum tendons were used and assigned into 10 groups. Two stitch configurations (Krackow stitch [K] and whipstitch [W]) with varying number of loops (2 throws, n = 6; 4 throws, n = 5; 6 throws, n = 5; 8 throws, n = 5; 10 throws, n = 5) were tested. No. 2 FiberWire was used. Each sample was preloaded to 5 N and then cyclically loaded for 200 cycles to 200 N at 1 Hz, and then the tendon-suture construct was analyzed for gap formation, tendon elongation, and tendon end width. Next, each tendon was loaded to failure, and ultimate strength and mode of failure were recorded. Data were evaluated with 2-way analysis of variance. Results: For gap formation, the Krackow stitch produced less gap compared with the whipstitch (15.2 ± 4.0 mm [K] vs 18.9 ± 6.8 mm [W]; P = .012). Gap formation was larger when the number of loops increased from 2 to ≥6 ( P = .015). For elongation, the Krackow technique increased the tendon length after cyclic loading. In contrast, the whipstitch was noted to shorten the length of the tendon (1.17 ± 0.97 mm [K] vs −0.14 ± 1.13 mm [W]; P < .001). For tendon end width, the Krackow better preserved the transverse width (–0.64 ± 0.81 mm [K] vs −1.39 ± 0.64 mm [W]; P = .001). Both stitch types had similar ultimate strength (322.1 ± 20.3 N [K] vs 319.7 ± 20.4 N [W]; P = .676) and modes of failure (all by suture breakage; therefore, no statistical calculation was performed). There was no statistical difference in tendon elongation, width, failure load, or mode regardless of the number of throws. Conclusion/Clinical Relevance: Given the finding that the Krackow suture had less gap formation and better preservation of tendon architecture (length and width) compared with the whipstitch, coupled with the finding that ultimate strength is similar with both types of sutures, the Krackow stitch is recommended for tendon reconstruction when these parameters are important.

1 April 2005 in Spine
Verified
Journal Article
Closed access
RDRichard A. DalCanto
Richard A. DalCanto
ILIsador Lieberman
Isador Lieberman
SISerkan Inceoglu
Serkan Inceoglu
MKMark Kayanja
Mark Kayanja
LFLisa Ferrara
Lisa Ferrara
In vitro biomechanical comparison of transarticular facet screws to lateral mass plates in two level instrumentations of the cervical spine. Lateral mass plates are costly, and screw placement is difficult. Facet screws have never been tested as an alternative in the cervical spine. This biomechanical study compared cervical transarticular facet screws to lateral mass plates in two-level instrumentations of human cadaveric cervical spines. Translaminar facet screws have been shown to have similar biomechanical performance to pedicle screw fixation in the lumbar spine, especially in flexion. They have proven to be fast, safe, and effective, with authors reporting 94% to 100% fusion rates in single-level lumbar fusions. However, a biomechanical comparison of transarticular facet screws to lateral mass plates in cervical spine instrumentations has not been reported. Thirteen human cadaveric cervical motion segments (C2–C4, C5–C7) were tested before and after instrumentation, with either transarticular facet screws or lateral mass plates, in flexion, extension, lateral bending, and torsion. Specimens were subjected to six cycles under a load of 2 Nm. Both fixation systems significantly reduced range of motion (ROM) and increased stiffness compared with the intact state in flexion, extension, lateral bending, and torsion. There were also no significant differences between the facet screws and plates in any of the four directions. To compare the two systems, ROM of each was analyzed relative to the uninstrumented state. Flexion was 0.26 (or 26% of the intact state) for the transarticular facet screws versus 0.20 for the lateral mass plates (P = 0.34), extension was 0.10 versus 0.07 (P = 0.43), lateral bending was 0.17 versus 0.15 (P = 0.52), and torque was 0.25 versus 0.38 (P = 0.12). Load to failure testing failed to indicate any differences between the two methods of fixation because all the specimens failed elsewhere. This study proves that transarticular facet screws and lateral mass plates are equivalent in two-level instrumentations of the cervical spine. This is the first biomechanical study to test transarticular facet screws in this context.

1 September 2016 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
SPShalin S. Patel
Shalin S. Patel
WAWilson Aruni
Wilson Aruni
SISerkan Inceoglu
Serkan Inceoglu
YAYusuf T. Akpolat
Yusuf T. Akpolat
GBGary D. Botimer
Gary D. Botimer
ODOlumide A. Danisa
Olumide A. Danisa