1 May 2017 in Physica Medica
18 August 2022 in Physica Medica
We propose a method that potentially improves the outcome of mutual-information-based automatic image registration by using the contrast enhancement filter (CEF). Seventy-six pairs of two-dimensional X-ray images and digitally reconstructed radiographs for 20 head and neck and nine lung cancer patients were analyzed retrospectively. Automatic image registration was performed using the mutual-information-based algorithm in VeriSuite®. Images were preprocessed using the CEF in VeriSuite®. The correction vector for translation and rotation error was calculated and manual image registration was compared with automatic image registration, with and without CEF. In addition, the normalized mutual information (NMI) distribution between two-dimensional images was compared, with and without CEF. In the correction vector comparison between manual and automatic image registration, the average differences in translation error were < 1 mm in most cases in the head and neck region. The average differences in rotation error were 0.71 and 0.16 degrees without and with CEF, respectively, in the head and neck region; they were 2.67 and 1.64 degrees, respectively, in the chest region. When used with oblique projection, the average rotation error was 0.39 degrees with CEF. CEF improved the NMI by 17.9 % in head and neck images and 18.2 % in chest images. CEF preprocessing improved the NMI and registration accuracy of mutual-information-based automatic image registration on the medical images. The proposed method achieved accuracy equivalent to that achieved by experienced therapists and it will significantly contribute to the standardization of image registration quality.
1 December 2020 in Physica Medica
High-speed cone-beam computed tomography (CBCT) scan for image-guided radiotherapy (IGRT) can reduce both the scan time and the exposure dose. However, it causes noise and artifacts in the reconstructed images due to the lower number of acquired projection data. The purpose of this study is to improve the image quality of high-speed CBCT using a deep convolutional neural network (DCNN). CBCT images of 36 prostate cancer patients were selected. The CBCT images acquired at normal scan speed were defined as CBCT100%. Simulated high-speed CBCT images acquired at twofold and fourfold scan speed were created, which were defined as CBCT50% and CBCT25%, respectively. The image quality of the CBCT50% was treated as the requirement for IGRT in this study because previous studies reported that its image is sufficient with respect to IGRT. The DCNN model was trained to learn direct mapping from CBCT25% to the corresponding CBCT100%. The performance of the DCNN model was evaluated using the sixfold cross-validation method. CBCT images generated by DCNN (CBCT25%+DCNN) were evaluated for voxel value accuracy and image quality. The DCNN model can process CBCT25% of a new patient within 0.06 s/slice. The CBCT25%+DCNN was comparable to the CBCT50% in terms of both voxel value accuracy and image quality. We developed a DCNN model to remove noise and artifacts from high-speed CBCT. We emphasize that it is possible to reduce exposure to one quarter and to increase the CBCT scan speed by a factor of four.
27 March 2023 in Anticancer Research
Background/Aim: This study pursued two goals: Firstly, to search for anatomical structures strongly correlating with dose deterioration, and secondly to investigate the effectiveness of image registration focusing on critical anatomy by comparing it with a conventional method. The aim was to achieve robust image registration to correct for anatomical changes during treatment. Patients and Methods: Twenty patients with head and neck cancer were enrolled, and 68 simulation computed tomography (CT) and rescan CT image sets were retrospectively analyzed. Forty volumetric-modulated arc therapy and intensity-modulated proton therapy plans were generated and recalculated according to the rescan CT to evaluate the dose effects of anatomical changes. Correlation coefficients were calculated for the relationships between the six-axis motion of the anatomy and the dose indices for the clinical target volume (CTV) and organs at risk. In the image registration, we compared a conventional method and target-based registration that limited the registration range to the CTV and vertebrae. Results: The CTV coverage and spinal cord dose were correlated with the position error associated with the pitch and vertical position of the vertebrae, and the parotid gland and oral cavity dose were strongly correlated with the position error associated with the roll of the clivus and mandible. The target registration improved CTV coverage and suppressed the increase in dose to organs at risk compared with conventional methods. Conclusion: Monitoring vertebral alignment, the assessment and correction of positioning errors associated with the clivus and mandible position errors are important to ensure the quality of daily treatment. Target-based registration may allow for more robust image registration.
20 June 2024 in Journal of Applied Clinical Medical Physics
Background: Coincidence of the treatment and imaging isocenter coordinates is required to safely perform small‐margin treatments, such as stereotactic radiosurgery of multiple brain metastases. A comprehensive and direct methodology for verifying concordance of kilovoltage cone‐beam computed tomography (kV‐CBCT) and treatment coordinates using an x‐ray CT‐based polymer gel dosimeter (dGEL) and onboard kV‐CBCT was previously reported. Using this methodology, we tested the ability of a new commercially available x‐ray CT‐based polymer dGEL with a rapid response to provide efficient quality assurance (QA).Purpose: The aim of this study was to evaluate the robustness of the three‐dimensional geometric QA methodology using dGEL.Methods: The dGEL were commercially manufactured. The prescribed dose for each field was determined by visually identifying the 5, 10, and 20 Gy isodose lines. A linear accelerator was used to irradiate the gels with seven non‐coplanar beams. An in‐house analysis program was used to identify the beam axes and treatment isocenter in kV‐CBCT coordinates by processing the pre‐ and post‐irradiation CBCT images. The impact of the radiation dose on the test reproducibility was examined, and the detectability of an intentional geometric error was assessed.Results: The treatment isocenter was within 0.4 mm of the imaging isocenter for all radiation doses. The residual error of the test with the intentional error was within 0.2 mm. The analysis and image quality variations for a single dGEL introduced displacement errors less than 0.3 mm.Conclusions: The test assessed the coincidence of treatment and kV‐CBCT isocenter coordinates and detected errors with high robustness. Even for a 10 Gy dose, the test yielded results comparable with those obtained using higher radiation doses owing to the rapid response of the dGEL dosimeter.
1 August 2017 in Medical Physics