Charlie C. Yang

Charlie C. Yang

Auto-generated profile, based on publicly available information

Charlie C. Yang

Colorado Joint Replacement, Denver, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2018 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
JJJason M. Jennings
Jason M. Jennings
SWSamuel Bs White
Samuel Bs White
JMJ. Ryan Martin
J. Ryan Martin
CYCharlie C. Yang
Charlie C. Yang
TMTodd M. Miner
Todd M. Miner
DDDouglas A. Dennis
Douglas A. Dennis
Background: The risk of early complications is high after monoblock acetabular metal-on-metal (MoM) THA revisions. However, there is a paucity of evidence regarding clinical complications after isolated head-liner exchange of modular MoM THA. Questions/purposes: The purposes of this study were (1) to describe the frequency of early complications after an isolated head-liner exchange revision of modular MoM THA; and (2) to determine whether patients who experienced complications or dislocation after head-liner exchanges had higher serum chromium (Cr) or cobalt (Co) ion levels than those who did not. Methods: A review of our institution’s total joint registry retrospectively identified 53 patients who underwent 54 liner exchange revisions of a modular acetabular MoM THA. The study period was from April 2008 to April 2016 at a single tertiary care center. During this period, isolated head-liner exchanges (rather than more extensive revisions) were performed in patients if they did not have evidence of loosening of the acetabular or femoral components. Reasons for revision surgery included pain, mechanical symptoms, radiographic evidence of osteolysis, elevated serum metal ions, and MRI abnormalities with 40 of the 54 hips having pain or mechanical symptoms and 38 of 54 hips having multiple reasons for revision before surgery. Patients were excluded if they did not meet the minimum postrevision followup or had the modular liner exchange secondary to infection. All revisions were from a single manufacturer with one head-liner exchange of a MoM THA from another manufacturer excluded during the study period. The mean time from index MoM THA to modular exchange was 96 (SD ± 36) months. Because the focus of this study was early complications, we had a minimum 90-day followup duration for inclusion. Mean followup after revision was 15 months (SD ± 12); a total of 56% (30 of 54) had followup of at least 12 months’ duration. Complications (dislocation, infection) and reoperations were obtained by chart review performed by individuals other than the treating physician(s). Serum metal ion levels were obtained before head-liner exchange. The median serum Cr and Co levels were 6 µg/L (range, 0-76 µg/L) and 12 µg/L (range, 0-163 µg/L), respectively. Results: Of the 54 revision THAs, 15 (28%) developed complications. Nine (17%) occurred within 90 days of the revision surgery and 11 (20%) resulted in reoperation. The most common complication was dislocation (12 of 54 [22%]) with recurrent dislocation noted in eight of these 12 patients. All patients with recurrent dislocation continued to dislocate and underwent repeat revision. Patients with dislocation had higher median serum Cr and Co ion levels than those without dislocation (Cr: 24 [range, 11-76] versus 4 [range, 0-70], p = 0.001 [95% confidence interval {CI}, 10-57]; Co: 41 [range, 6-163] versus 8 [range, 0-133], p = 0.016 [95% CI, 6-141]). Three (6%) of the 54 patients underwent repeat surgery for deep space infection. Conclusions: Complications and reoperations are common after modular head-liner exchange in the setting of a failed MoM THA. Our study likely underestimates the frequency of complications and revisions because the followup period in this report was relatively short. Dislocation is the most common complication and elevated serum metal ion levels may be a predictor of dislocation. These findings are concerning and surgeons should be aware of the high complication risk associated with this procedure. Level of Evidence: Level IV, therapeutic study.

1 September 2023 in Arthroplasty
Verified
Journal Article
Open access
PDF file
ADAdam Driesman
Adam Driesman
CYCharlie C. Yang
Charlie C. Yang
Total hip arthroplasty (THA) has been one of the most successful surgical interventions in recent memory and is nicknamed by some the “Surgery of the Century”. Over the past decade, there has been a drastic change in THA management with the rise of the direct anterior approach both globally and in the USA market. While many would remark that this has been driven by false marketing, it is clear that the direct anterior approach can be an effective and safe way to perform a THA.It is the goal of this review to highlight evidence of its outcomes and clinical advantages, in particular, how it can decrease dislocation, even in high-risk individuals, and result in faster recovery in the early postoperative period with decreased muscular inflammation. We will also highlight its major disadvantages, including but not limited to increased wound complications and risk for periprosthetic fracture. Hopefully, this review will provide up-to-date information on the current state of the direct anterior approach and provide recommendations on patients that would be optimal candidates for this technique.

1 April 2018 in Annals of Joint
Verified
Journal Article
Closed access
PDF file
BDBrian K. Daines
Brian K. Daines
CYCharlie C. Yang
Charlie C. Yang
The direct anterior approach to the hip is an increasingly common approach for a total hip replacement. Fluoroscopic guidance can help evaluate bone preparation and component positioning. Traditional landmarks for establishing acetabular component position can be variable and lead to placement of the acetabular component outside Lewinnek’s safe zone. Fluoroscopic imaging has been shown to increase accuracy in acetabular cup position. Fluoroscopic imagining during the direct anterior approach has been shown to be safe and can be viewed as an advantage of the anterior hip approach.

1 April 2018 in Annals of Joint
Verified
Journal Article
Closed access
PDF file
DHDavid C. Holst
David C. Holst
MAMarc R. Angerame
Marc R. Angerame
CYCharlie C. Yang
Charlie C. Yang
The direct anterior approach (DAA) for total hip arthroplasty (THA) is an increasingly popular surgical approach with numerous benefits cited in the literature. However, it is not without a well-documented “learning curve”, during which time potential difficulties can occur. This article outlines the authors’ technique of performing the DAA on a standard operating room table, with particular attention paid to technical specifics that may be helpful to the surgeon in performing this operation safely.