Alexandros Rigas

Alexandros Rigas

Auto-generated profile, based on publicly available information

Alexandros Rigas

School of Electrical and Computer Engineering, National Technical University of Athens, Greece

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
GMGeorge M. Messinis
George M. Messinis
ARAlexandros E. Rigas
Alexandros E. Rigas
NHNikosHatziargyriou Hatziargyriou
NikosHatziargyriou Hatziargyriou
Non technical losses (NTL) is a major problem faced by DSOs all over the world. Traditional meter inspection techniques are not effective in detecting NTL, while the wide adoption of smart meters and smart grid technologies provides new opportunities towards solving the problem. The proposed NTL detection system utilizes voltage sensitivity analysis, power system optimization and Support Vector Machines (SVM) for correctly detecting NTLs in the distribution grid under various conditions. Breakout detection is used for extracting features from consumption time series and training an SVM classifier. Generalized least squares is used for estimating the network voltage self-sensitivities. Finally, the NTL detection problem is formed as a non-linear non-convex optimization problem solved with semi-definite programming relaxation. The three modules can be operated either autonomously or combined. The proposed NTL detection system is demonstrated under different scenarios to test its effectiveness.

2 May 2016 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Panos KotsampopoulosPanos Kotsampopoulos
Panos Kotsampopoulos
ARA. Rigas
A. Rigas
JKJ. Kirchhof
J. Kirchhof
GMG. Messinis
G. Messinis
ADA. Dimeas
A. Dimeas
KAK. Andreadis
K. Andreadis
Electronic-smart meters are increasingly installed in electricity networks of many countries. In several cases, their operation in parallel with photovoltaic inverters and other power-electronic devices can result in measurement errors reaching up to 45%. In practice, this problem cannot be tackled by current standards due to the gap in standardization of electromagnetic immunity and emissions in the 2-150 kHz range. This paper provides a comprehensive review of international and national standards, guidelines, technical reports, and papers on this challenging electromagnetic-compatibility issue highlighting the gap in the 2-150 kHz range. The ongoing standardization activity to establish both emission and immunity levels and suitable testing procedures is described in detail. Laboratory setups for testing the immunity of smart meters and the emissions of grid-tie inverters are described and experimental results to validate the suitability of the proposed approaches are presented.

1 January 2014
Verified
Conference Paper
Closed access
CPC.N. Papadimitriou
C.N. Papadimitriou
VKV.A. Kleftakis
V.A. Kleftakis
ARA. Rigas
A. Rigas
NHN.D. Hatziargyriou
N.D. Hatziargyriou
DC Microgrids (DC MGs) gain popularity as they present attractive features such as: high system efficiency, high power quality, reduced cost, reduced power conversions and less complex control. This paper presents a local control strategy of a DC MG consisting of a fuel cell and a composite energy storage system that includes super capacitors and a battery bank. The control strategy is based on the local measurement of the common DC bus voltage. The different levels of the DC bus voltage serve as an information carrier and dictate the different operation modes of the microsources (DC bus signaling). The proposed control strategy also takes under consideration the appropriate load management, which involves load shedding based on predefined load priority levels, that may be necessary during abnormal or island conditions. The control is tested via simulation studies under islanded, interconnected mode and under transitions proving satisfying response.

1 January 2014
Verified
Conference Paper
Closed access
GMG. Messinis
G. Messinis
VKV. Kleftakis
V. Kleftakis
IKIasonas Kouveliotis-Lysikatos
Iasonas Kouveliotis-Lysikatos
ARA. Rigas
A. Rigas
AVA. Vassilakis
A. Vassilakis
NHN. Hatziargyriou
N. Hatziargyriou
The Electrical Energy Systems laboratory will be described in this paper. The EES lab includes two microgrids combined with the Electrical Machines laboratory microgrid. Two of them are single phase and one of them is a three phase microgrid. The components installed include PVs, Small Wind Turbine, Batteries and Loads. A description of the various components and their operation is provided. A SCADA is used to monitor and control microgrid components through an HMI. The communication infrastructure will be described and the SCADA functionalities will be presented for the single phase microgrid. In addition, the laboratory Hardware in the Loop test bed used to test DER control algorithms and power components will be presented. A Multi-Agent system platform that includes smart load controllers for testing distributed controls will also be described. Furthermore, the future laboratory infrastructure will be presented, where all three microgrids are interconnected. The future SCADA will integrate all three microgrids and will take advantage of state of the art communication protocols and data interoperability standards. The new SCADA system will enable for faster implementation and testing of microgrid control algorithms, since researchers will not carry the burden of low level communication and data engineering.

1 October 2013
Verified
Conference Paper
Closed access
VKV. Kleftakis
V. Kleftakis
ARA. Rigas
A. Rigas
AVA. Vassilakis
A. Vassilakis
PKP. Kotsampopoulos
P. Kotsampopoulos
NHN. Hatziargyriou
N. Hatziargyriou
Power-Hardware-in-the-Loop (PHIL) simulation is a promising method for studying the interaction of various complex components in current and future electricity grids. This paper firstly examines the applicability of PHIL simulation to Fault-Ride-Through tests. A test setup is implemented with a hardware PV inverter as the Hardware Under Test (HUT). Furthermore, the PHIL method is employed for testing and validating the capability of a D-STATCOM to compensate voltage dips. An average model of a D-STATCOM is developed in the RTDS ® and its influence on the operation of the hardware PV inverter is investigated.

11 August 2016
Verified
Conference Paper
Closed access
SKStavros Karagiannopoulos
Stavros Karagiannopoulos
ARAlexandros Rigas
Alexandros Rigas
NHNikos Hatziargyriou
Nikos Hatziargyriou
GHGabriela Hug
Gabriela Hug
AOAlexandre Oudalov
Alexandre Oudalov
As manufacturing costs keep decreasing, battery energy storage systems (BESS) are expected to play a key role in modern grids. However, due to their energy constraints and internal losses, the restoration of the state of charge (SoC) to a reference range is of vital importance to fulfil their tasks. In this paper, we propose SoC control schemes based on existing ones, and then we evaluate their behavior in predictable and stochastic power system applications. The modifications include parameter tuning based on the actual BESS state, as well as alternating the control scheme according to forecasts of the application signal. Furthermore, we extend a Lithium-Ion battery model in order to quantify capacity degradation and hence, investigate the impact of the various SoC restoration strategies. Results show that potentials to increase the lifetime are application-dependent, based on the degree of flexibility allowed by a service. Overall, the calendar aging dominates the cycling aging and thus, there is limited space for improvement with different SoC control schemes. On the other hand, by incorporating forecast information, we can reduce the amount of energy needed for the SoC restoration and hence, decrease additional energy costs.