6 August 2007 in Physical Review B
Complex transverse susceptibility is a recent proposed method for the determination of anisotropy and volume distributions in particulate magnetic media. So far, only thermal fluctuations and rate-dependent damped dynamics of the magnetic moment have been identified as reasons for the existence of the imaginary transverse susceptibility. In this paper, we apply a more general approach to derive the complex transverse susceptibility, and we show that the hysteresis phenomenon is the most general concept behind the existence of complex transverse susceptibility. In this paper, the physical origins of the imaginary part of transverse susceptibility are analyzed: rate-independent hysteresis, viscous-type rate-dependent hysteresis, and thermal relaxation effect origin. The rate-independent origin is an intrinsic contribution to the imaginary transverse susceptibility and cannot be neglected because it is a zero-temperature effect.
11 January 2019 in Journal of Applied Physics
The first-order reversal curve (FORC) diagram method is one of the most successful characterization techniques used to characterize complex hysteretic phenomena not only in magnetism but also in other areas of science like in ferroelectricity, geology, archeology, in spin-transition materials, etc. Because the definition of the FORC diagram involves a second-order derivative, the main problem in their numerical calculation is that the derivative of a function for which only discrete noise-contaminated data values are available magnifies the noise that is inevitably present in measurements. In this paper, we present the doFORC tool for calculating FORC diagrams of noise scattered data. It can provide both a smooth approximation of the measured magnetization and all its partial derivatives. Even if doFORC is mainly dedicated to FORC diagrams’ computation, it can process a general set of arbitrarily distributed two-dimensional points. doFORC is a free, portable application working on various operating systems, with an easy to use graphical interface, with four regression methods implemented to obtain a smooth approximation of the data which may then be differentiated to obtain approximations for derivatives. In order to perform the diagnostics and goodness of fit, doFORC computes residuals to characterize the difference between the observed and predicted values, generalized cross-validation to measure the predictive performance, two information criteria to quantify the information that is lost by using an approximate model, and three degrees of freedom to compare different amounts of smoothing being performed by different smoothing methods. Based on these, doFORC can perform automatic smoothing parameter selection.
1 July 2007 in Journal of Applied Physics
In this paper we have studied the dynamic switching in magnetic random access memory (MRAM) and its dependence on thermal effects due to a finite temperature. The model is based on the Landau-Lifshitz-Gilbert equation and the stochastic Landau-Lifshitz-Gilbert equation which are numerically integrated. The magnetic layers are assumed to be ellipsoid shaped with each magnetic layer single domain. In addition, we have taken into account the uniaxial intrinsic anisotropy. Simulations were performed for both balanced and nonbalanced synthetic antiferromagnetic elements. The switching properties are discussed as a function of applied field pulses’ length and shape. In this paper we present how the thermal fluctuations affect the switching behavior, the reliability, and the writing speed of MRAM devices.
22 July 2026 in Journal of Applied Physics
Soft amorphous magnetic wires are promising magnetic materials for applications as magnetic logic devices, random access memory, integrated circuits, hard disks, and spintronic devices. These applications are based on the very fast propagation of a single domain wall inside the magnetic wires. Determination of the domain wall structure is an important task due to the role that it plays in the functioning of different applications. In this paper, we analyze the use of the induced signal in a Sixtus–Tonks type experiment to obtain information about domain wall geometry. Although this is a method often used in the scientific literature, we show that without considering the parameters of the detection coil the obtained results can be affected by significant errors. The physical origins of the induced signal are analyzed in this paper, calculating the signal by means of the effective surface and volume magnetization currents, for different types of domain walls. We show that the induced signal is due in part to the domain wall, and in part to the two uniformly magnetized domains separated by the domain wall. The latter contribution exists whatever the shape of the wall, and it can even almost cover the wall contribution. The results are important for understanding and controlling magnetic switching in magnetic wires for future applications. The systematic fundamental theoretical and modeling study presented in this paper is showing the capability and the limits of the inductometric wall detection tools to understand the observed signals measured in experimental setups used in various applications.
2 December 2014 in IEEE Transactions on Magnetics
In this paper, the influence of ac field frequency on transverse susceptibility (TS) curves was investigated. Two different experimental setups were used to reach the excitation frequency of 6 GHz. At low frequencies, the real and imaginary parts of the susceptibility were directly obtained by measuring the impedance of a coil incorporating the sample using a RLC bridge. In the microwave frequency domain, the susceptibility was correlated with the scattering parameters of a transmission line containing the sample. The experimental data show that for a Ni-Zn ferrite polycrystalline sample Ni0.65Zn0.35Fe2O4 and for ac field frequencies up to 100 MHz, the TS peeks do not present an important shift in field positions. The measured real and imaginary parts of the TS have the same peek structure, but the amplitude and line width differ. At higher ac frequencies, the peeks field are frequency dependent and a supplementary peek was observed.