Bronwyn A. Lucas

Bronwyn A. Lucas

Auto-generated profile, based on publicly available information

Bronwyn A. Lucas

University of California Berkeley

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2021 in eLife
Verified
Journal Article
Open access
BLBronwyn A Lucas
Bronwyn A Lucas
BHBenjamin A Himes
Benjamin A Himes
LXLiang Xue
Liang Xue
TGTimothy Grant
Timothy Grant
JMJulia Mahamid
Julia Mahamid
NGNikolaus Grigorieff
Nikolaus Grigorieff
For a more complete understanding of molecular mechanisms, it is important to study macromolecules and their assemblies in the broader context of the cell. This context can be visualized at nanometer resolution in three dimensions (3D) using electron cryo-tomography, which requires tilt series to be recorded and computationally aligned, currently limiting throughput. Additionally, the high-resolution signal preserved in the raw tomograms is currently limited by a number of technical difficulties, leading to an increased false-positive detection rate when using 3D template matching to find molecular complexes in tomograms. We have recently described a 2D template matching approach that addresses these issues by including high-resolution signal preserved in single-tilt images. A current limitation of this approach is the high computational cost that limits throughput. We describe here a GPU-accelerated implementation of 2D template matching in the image processing software cisTEM that allows for easy scaling and improves the accessibility of this approach. We apply 2D template matching to identify ribosomes in images of frozen-hydrated Mycoplasma pneumoniae cells with high precision and sensitivity, demonstrating that this is a versatile tool for in situ visual proteomics and in situ structure determination. We benchmark the results with 3D template matching of tomograms acquired on identical sample locations and identify strengths and weaknesses of both techniques, which offer complementary information about target localization and identity.

22 May 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
BLBronwyn A. Lucas
Bronwyn A. Lucas
NGNikolaus Grigorieff
Nikolaus Grigorieff
Cryogenic electron microscopy (cryo-EM) can reveal the molecular details of biological processes in their native, cellular environment at atomic resolution. However, few cells are sufficiently thin to permit imaging with cryo-EM. Thinning of frozen cells to <500 nm lamellae by focused-ion-beam (FIB) milling has enabled visualization of cellular structures with cryo-EM. FIB milling represents a significant advance over prior approaches because of its ease of use, scalability, and lack of large-scale sample distortions. However, the amount of damage it causes to a thinned cell section has not yet been determined. We recently described an approach for detecting and identifying single molecules in cryo-EM images of cells using 2D template matching (2DTM). 2DTM is sensitive to small differences between a molecular model (template) and the detected structure (target). Here, we use 2DTM to demonstrate that under the standard conditions used for machining lamellae of biological samples, FIB milling introduces a layer of variable damage that extends to a depth of 60 nm from each lamella surface. This layer of damage limits the recovery of information for in situ structural biology. We find that the mechanism of FIB milling damage is distinct from radiation damage during cryo-EM imaging. By accounting for both electron scattering and FIB milling damage, we estimate that FIB milling damage with current protocols will negate the potential improvements from lamella thinning beyond 90 nm.

25 August 2022 in eLife
Verified
Journal Article
Open access
BLBronwyn A Lucas
Bronwyn A Lucas
KZKexin Zhang
Kexin Zhang
SLSarah Loerch
Sarah Loerch
NGNikolaus Grigorieff
Nikolaus Grigorieff
Previously, we showed that high-resolution template matching can localize ribosomes in two-dimensional electron cryo-microscopy (cryo-EM) images of untilted Mycoplasma pneumoniae cells with high precision (Lucas et al., 2021). Here, we show that comparing the signal-to-noise ratio (SNR) observed with 2DTM using different templates relative to the same cellular target can correct for local variation in noise and differentiate related complexes in focused ion beam (FIB)-milled cell sections. We use a maximum likelihood approach to define the probability of each particle belonging to each class, thereby establishing a statistic to describe the confidence of our classification. We apply this method in two contexts to locate and classify related intermediate states of 60S ribosome biogenesis in the Saccharomyces cerevisiae cell nucleus. In the first, we separate the nuclear pre-60S population from the cytoplasmic mature 60S population, using the subcellular localization to validate assignment. In the second, we show that relative 2DTM SNRs can be used to separate mixed populations of nuclear pre-60S that are not visually separable. 2DTM can distinguish related molecular populations without the need to generate 3D reconstructions from the data to be classified, permitting classification even when only a few target particles exist in a cell.

27 November 2023 in eLife
Verified
Journal Article
Open access
BLBronwyn A Lucas
Bronwyn A Lucas
BHBenjamin A Himes
Benjamin A Himes
NGNikolaus Grigorieff
Nikolaus Grigorieff
Previously we showed that 2D template matching (2DTM) can be used to localize macromolecular complexes in images recorded by cryogenic electron microscopy (cryo-EM) with high precision, even in the presence of noise and cellular background (Lucas et al., 2021; Lucas et al., 2022). Here, we show that once localized, these particles may be averaged together to generate high-resolution 3D reconstructions. However, regions included in the template may suffer from template bias, leading to inflated resolution estimates and making the interpretation of high-resolution features unreliable. We evaluate conditions that minimize template bias while retaining the benefits of high-precision localization, and we show that molecular features not present in the template can be reconstructed at high resolution from targets found by 2DTM, extending prior work at low-resolution. Moreover, we present a quantitative metric for template bias to aid the interpretation of 3D reconstructions calculated with particles localized using high-resolution templates and fine angular sampling.

7 June 2023 in Current Opinion in Structural Biology
Verified
Journal Article
Open access
BLBronwyn A. Lucas
Bronwyn A. Lucas
Twenty years ago, the release of the first draft of the human genome sequence instigated a paradigm shift in genomics and molecular biology. Arguably, structural biology is entering an analogous era, with availability of an experimentally determined or predicted molecular model for almost every protein-coding gene from many genomes-producing a reference "structureome". Structural predictions require experimental validation and not all proteins conform to a single structure, making any reference structureome necessarily incomplete. Despite these limitations, a reference structureome can be used to characterize cell state in more detail than by quantifying sequence or expression levels alone. Cryogenic electron microscopy (cryo-EM) is a method that can generate atomic resolution views of molecules and cells frozen in place. In this perspective I consider how emerging cryo-EM methods are contributing to the new field of structureomics.

17 January 2025 in IUCrJ
Verified
Journal Article
Open access
PDF file
KZKexin Zhang
Kexin Zhang
Pilar CossioPilar Cossio
Pilar Cossio
ARAaditya V. Rangan
Aaditya V. Rangan
BLBronwyn A. Lucas
Bronwyn A. Lucas
NGNikolaus Grigorieff
Nikolaus Grigorieff
2D template matching (2DTM) can be used to detect molecules and their assemblies in cellular cryo-EM images with high positional and orientational accuracy. While 2DTM successfully detects spherical targets such as large ribosomal subunits, challenges remain in detecting smaller and more aspherical targets in various environments. In this work, a novel 2DTM metric, referred to as the 2DTM p-value, is developed to extend the 2DTM framework to more complex applications. The 2DTM p-value combines information from two previously used 2DTM metrics, namely the 2DTM signal-to-noise ratio (SNR) and z-score, which are derived from the cross-correlation coefficient between the target and the template. The 2DTM p-value demonstrates robust detection accuracies under various imaging and sample conditions and outperforms the 2DTM SNR and z-score alone. Specifically, the 2DTM p-value improves the detection of aspherical targets such as a modified artificial tubulin patch particle (500 kDa) and a much smaller clathrin monomer (193 kDa) in simulated data. It also accurately recovers mature 60S ribosomes in yeast lamellae samples, even under conditions of increased Gaussian noise. The new metric will enable the detection of a wider variety of targets in both purified and cellular samples through 2DTM.