24 January 2020 in IEEE Robotics and Automation Letters
This letter focuses on the 3D path-following ofa spiraltype helical magnetic swimmer in a water-filled workspace. The swimmer has a diameter of 2.5 mm, a length of 6 mm, and is controlled by an external time-varying magnetic field. A method to compensate undesired magnetic gradient forces is proposed and tested. Five swimmer designs with different thread pitch values were experimentally analyzed. All were controlled by the same model reference adaptive controller (MRAC). Compared to a conventional hand-tuned PI controller, their 3D path-following performance is significantly improved by using MRAC. At an average speed of 50 mm/s, the path-following mean error of the MRAC is 3.8 ± 1.8 mm, less than one body length of the swimmer. The versatility of this new controller is demonstrated by analyzing pathfollowing through obstacles on a helical trajectory and forward & backward motion.
31 January 2025 in Otolaryngology–Head and Neck Surgery
10 December 2021 in Proceedings of IMPRS
Background and Hypothesis: Vagus nerve stimulation (VNS) is used for treatment of epilepsy in over 100,000 patients worldwide and is a potential treatment for many inflammatory disorders. VNS-evoked compound nerve action potentials (CNAPs) may have applications as a biomarker of VNS treatment efficacy, but transcutaneous measurement of this activity is obscured by muscle artifacts. A more precise understanding of muscle activation patterns could improve recording and analysis protocols for isolating the vagus nerve (VN) CNAP. We hypothesize that analyzing multi-electrode array (MEA) surface recordings overlying the VN will allow us to characterize this muscle artifact. Project Methods: Five patients undergoing VNS therapy for epilepsy were enrolled in a clinical study at Indiana University School of Medicine (IRB #2006075899). A custom-made MEA with a grid of 32 soft foam electrodes was placed on the skin overlying the VN on each side of the neck. Surface potentials were recorded for approximately 20 minutes at the patient’s established device settings. Results: VNS-evoked potentials were visualized in all five patients. Two probable muscle artifacts were identified, defined as non-propagating features in the mean response to n > 600 pulses of VNS. The first had an onset latency of ~1-3 ms, and the second had a latency of ~7-10 ms. Both artifacts appeared primarily in the electrodes overlying the laryngeal muscles. Conclusion and Potential Impact: The short latency of the first muscle artifact suggests stimulus signal leakage activating the superior laryngeal nerve. The second artifact with longer latency is likely caused by the recurrent laryngeal nerve. Previous analyses may have mischaracterized the first muscle artifact as nerve activity. The use of MEA-based recordings clarifies our understanding of the VN’s response to VNS, which may lead to better treatment efficacy and the eventual development of personalized VNS therapies for epilepsy and a range of inflammatory disorders.
20 December 2024 in Journal of Voice
17 February 2025 in Head & Neck