Jari Peltola

Jari Peltola

Auto-generated profile, based on publicly available information

Jari Peltola

Laboratory of Physical Chemistry, Department of Chemistry, P.O. Box 55 (A.I. Virtasen aukio 1), FIN-00014 University of Helsinki, Finland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
MVMarkku Vainio
Markku Vainio
JPJari Peltola
Jari Peltola
SPStefan Persijn
Stefan Persijn
FHFrans Harren
Frans Harren
LHLauri Halonen
Lauri Halonen
A singly resonant continuous-wave optical parametric oscillator (cw OPO) is described. The OPO contains no intracavity etalon, which makes its wavelength tuning simple and straightforward, including only temperature tuning of the nonlinear crystal and wavelength tuning of the pump laser. The OPO provides watt-level output in the mid-infrared region and operates reliably without mode hops for several hours.

15 November 2008 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
MVM. Vainio
M. Vainio
JPJ. Peltola
J. Peltola
SPStefan Persijn
Stefan Persijn
FHFrans Harren
Frans Harren
LHL. Halonen
L. Halonen

16 June 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
JPJari Peltola
Jari Peltola
THTuomas Hieta
Tuomas Hieta
MVMarkku Vainio
Markku Vainio
We present a simple and highly sensitive cantilever-enhanced photo-acoustic sensor for detection of nitrogen dioxide. A noise equivalent detection limit of 50 parts-per-trillion in 1 s is demonstrated. The limit was reached with an average optical power of 4.7 W using a continuous-wave laser at 532 nm. The achieved normalized noise equivalent absorption coefficient was 2.6×10−10  W cm−1 Hz−1/2.

18 April 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
JPJari Peltola
Jari Peltola
MVMarkku Vainio
Markku Vainio
THTuomas Hieta
Tuomas Hieta
JUJuho Uotila
Juho Uotila
SSSauli Sinisalo
Sauli Sinisalo
LHLauri Halonen
Lauri Halonen
Highly sensitive cantilever-enhanced photoacoustic detection of hydrogen cyanide and methane in the mid-infrared region is demonstrated. A mid-infrared continuous-wave frequency tunable optical parametric oscillator was used as a light source in the experimental setup. Noise equivalent detection limits of 190 ppt (1 s) and 65 ppt (30 s) were achieved for HCN and CH4, respectively. The normalized noise equivalent absorption coefficient is 1.8 × 10−9 W cm−1 Hz−1/2.

7 April 2020 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
JPJari Peltola
Jari Peltola
PSPrasenjit Seal
Prasenjit Seal
AIAnni Inkilä
Anni Inkilä
AEArkke Eskola
Arkke Eskola
We present a time-resolved broadband cavity-enhanced UV-absorption spectrometer apparatus that we have constructed and utilized for temperature- and pressure-dependent kinetic measurements of formaldehyde oxide (CH 2 OO) reactions.

13 September 2010 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MVMarkku Vainio
Markku Vainio
MSMikael Siltanen
Mikael Siltanen
JPJari Peltola
Jari Peltola
LHLauri Halonen
Lauri Halonen
The use of grating as a spectral filter provides a simple way of improving wavelength tuning and stability of continuous-wave optical parametric oscillators (cw OPOs). In this paper, we discuss how to design and use such grating-cavity cw OPOs for high-resolution spectroscopy in the molecular fingerprint region at ∼3μm. The first design presented in the paper is based on a metal-coated diffraction grating, which produces fast and broad wavelength tuning and high wavelength stability. The second design uses a bulk Bragg grating for high optical power and good spectral purity. We report a new Bragg-grating OPO and demonstrate its use in a Doppler-free absorption spectroscopy of CH4 at ∼3.22μm. In addition, we describe a new balanced detection scheme, which can be used to improve the signal-to-noise ratio of absorption measurements if the measurement noise is limited by the intensity noise of the mid-infrared OPO.