D.L. Yu

D.L. Yu

Auto-generated profile, based on publicly available information

D.L. Yu

Southwestern Institute of Physics, PO Box 432, Chengdu 610041, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2016 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
DYD.L. Yu
D.L. Yu
YWY.L. Wei
Y.L. Wei
LLL. Liu
L. Liu
JDJ.Q. Dong
J.Q. Dong
KIK. Ida
K. Ida
HTHl-2A Team
Hl-2A Team
Ion internal transport barriers (iITBs) are first observed in neutral beam injection (NBI) heated plasmas at the HL-2A tokamak. The position of the barrier foot, in the stationary state, coincides with the q = 1 surface within its uncertainty of measurement. iITBs can develop more easily at the beginning of NBI heating. Also, iITBs are unstable for the sawtooth plasma. Simulations reveal that the thermal diffusivity of ions (χ i) inside the barrier can be as low as the neoclassical level. It is observed that the flow shear in the stationary iITB state reaches the level required for suppressing the ion temperature gradient mode instability, which indicates the important role of flow shear in sustaining the iITB.

10 July 2014 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DYD. L. Yu
D. L. Yu
YWY. L. Wei
Y. L. Wei
LLL. Liu
L. Liu
JCJ. Y. Cao
J. Y. Cao
QMQ. Ma
Q. Ma
XDX. R. Duan
X. R. Duan
A 32/64-channel Charge eXchange Recombination Spectroscopy (CXRS) and a 7-channel motional Stark effect (MSE) polarimeter have been developed on the HL-2A tokamak. To extract the maximum time resolution of the system, the incidence fibers of the spectrometer are pitch-controlled; and the double-slit fiber bundle can increase the spatial channels with one charge-coupled device detector. The ion temperature and plasma rotation with time and spatial resolutions up to 5 ms and 1 cm are obtained. Sawtooth oscillation, transition from intermediate phase (I phase) to high confinement mode (H mode) can be clearly observed by the CXRS. The spectrometer can be utilized as the main component of the MSE polarimeter, which can effectively overcome the weak Stark effect. The pitch angles of magnetic field are obtained for 7 spatial points covering 24 cm along major radius with time resolution of 40 ms.

4 July 2012 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
DYD.L. Yu
D.L. Yu
CCC.Y. Chen
C.Y. Chen
LYL.H. Yao
L.H. Yao
JDJ.Q. Dong
J.Q. Dong
BFB.B. Feng
B.B. Feng
YLYong Liu
Yong Liu
Features of high fuelling efficiency of supersonic molecular beam injection (SMBI) are studied on the HL-2A tokamak. Normalized by fuelled particle inventory, the D α emission induced by SMBI is about 50% higher than that of gas puffing (GP), indicating that a higher percentage of fuel injected by SMBI will enter the plasma. Strong particle convection (inward pinch) is observed with a hydrogen cyanide (HCN) interferometer as the densities from the core and edge channels increase and decrease, respectively, in the post-fuelling phase. In addition, microwave reflectometry indicates that the peak of fuelled density moves inward. By comparing the SMBI pulses with and without electron cyclotron resonance heating, it is identified that the pinch is driven by the enhancement of electron temperature gradient. Higher enhancement (up to twice) of the normalized electron temperature gradient is observed for SMBI than for GP, and this is another mechanism for the higher fuelling efficiency of SMBI.

19 February 2016 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
WCW. Chen
W. Chen
LYL.M. Yu
L.M. Yu
XDX.T. Ding
X.T. Ding
HXH.S. Xie
H.S. Xie
ZSZ.B. Shi
Z.B. Shi
HTHl-2A Team
Hl-2A Team
Recent experimental results that are associated with the core-localized (i.e. normalized radius ) Alfvénic modes in HL-2A neutral beam injection (NBI) plasmas with weak magnetic shears are reported. In the different plasma parameter regions, the energetic ions produced by the NBI drive multiple Alfvénic instabilities, such as the toroidal Alfvén eigenmode (TAE), beta-induced Alfvén eigenmode, reversed shear Alfvén eigenmode (RSAE) and fishbone and energetic particle mode (EPM). Here, we focus on the high-frequency RSAE (HFRSAE) and resonant kinetic ballooning mode (rKBM). A group of downward-sweeping frequency coherent modes (HFRSAEs) with 100 < f < 500 kHz and n = 3–7 are often observed with an increase in the edge safety factor, q a . Their measured frequency is more than that of the TAEs, and . The analysis suggests that these modes localize inside the high-order Alfvén eigenmode (AE) gap of the Alfvénic continuum, and their eigenfrequency and eigenfunction depend on the and q-profile. When the core plasma density is more than m−3 and the impurity or supersonic molecular beam enters the bulk plasma, the profiles of the plasma density/pressure peak, and the magnetic shear is weak or negative. In this case, a group of multi-harmonic coherent modes (rKBMs) with 30 < f < 150 kHz and n = 2–9 are observed through multiple diagnostic techniques, and , where is the diamagnetic drift frequency of the thermal ion. It is found that the HFRSAEs can transit into the rKBMs when the density profile suddenly peaks. Neutron monitoring outside the vacuum chamber demonstrates that the HFRSAE and rKBM both degrade the confinement of the energetic ions. The rKBM instabilities also affect the bulk plasma performance.

8 September 2016 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
QMQ. Ma
Q. Ma
DYD.L. Yu
D.L. Yu
CCC.Y. Chen
C.Y. Chen
YWY.L. Wei
Y.L. Wei
WZW.L. Zhong
W.L. Zhong
HTHl-2A Team
Hl-2A Team
Edge localized mode (ELM) is successfully mitigated by helium and deuterium supersonic molecular beam injections (SMBIs) on HL-2A. During the ELM mitigation by SMBIs, gradients of ion temperature (T i) and electron density are softened in the pedestal. It has been observed that the averaged gradient of the T i decreases around 44% and the well depth of radial electric field (E r) is reduced by the SMBI during ELM mitigation. Furthermore, at least 20% decrements of T i have to be attained to achieve a noticeable increase (decrease) of the ELM frequency (amplitude). In addition, the duration of ELM mitigation with helium SMBI is much longer than that with deuterium, likely due to the higher level of recycling neutral gas compared to that of deuterium; in the case of ELM mitigation by helium SMBI, the recovery duration of the density gradient is much shorter (10–20 ms) than that of T i (up to 40 ms or longer), indicating the importance of the T i in the ELM mitigation by SMBI. Finally, it has been observed that the T i is reduced before the beginning of the ELM mitigation, suggesting that the mechanism of the ELM mitigation by SMBI is closely related to the cooling effect.

1 May 2020 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
DYD. L. Yu
D. L. Yu
LYL. W. Yan
L. W. Yan
LLL. Liu
L. Liu
WCW. J. Chen
W. J. Chen
YWY. L. Wei
Y. L. Wei
XDX. R. Duan
X. R. Duan
A Fast Charge eXchange Recombination Spectroscopy (CXRS) diagnostic with eight radial channels has been implemented on a HuanLiu-2A (HL-2A) tokamak with a time resolution of up to 10 kHz monitoring helium II spectra or 1 kHz monitoring carbon VI spectra. The crucial aspects of the fast CXRS are to improve the spectral intensity and the acquisition frequency. The spectral intensity has been greatly enhanced by customized fiber bundles. The main boost in optimizing the acquisition frequency is achieved by binning more pixel rows of the charge coupled device (CCD) representing one radial channel and by reducing the effective image area of the CCD. Consequently, the sawtooth oscillations of ion temperature and rotation velocity are continuously observed for the first time in the HL-2A tokamak.