Joydeep Mitra

Joydeep Mitra

Auto-generated profile, based on publicly available information

Joydeep Mitra

Michigan State University

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2009 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ESEric Sortomme
Eric Sortomme
SVS. S. Venkata
S. S. Venkata
JMJoydeep Mitra
Joydeep Mitra
Microgrids have been proposed as a way of integrating large numbers of distributed renewable energy sources with distribution systems. One problem with microgrid implementation is designing a proper protection scheme. It has been shown that traditional protection schemes will not work successfully. In this paper a protection scheme using digital relays with a communication network is proposed for the protection of the microgrid system. The increased reliability of adding an additional line to form a loop structure is explored. Also a novel method for modeling high impedance faults is demonstrated to show how the protection scheme can protect against them. This protection scheme is simulated on a realistic distribution system containing a high penetration of inverter connected Distributed Generation (DG) sources operating as a microgrid. In all possible cases of operation the primary and secondary relays performed their intended functions including the detection of high impedance faults. This system is simulated using Matlab Simulink's SimPowerSystems toolbox to establish the claims made in this paper.

11 March 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
AMAbir Muhtadi
Abir Muhtadi
DPDilip Pandit
Dilip Pandit
NNNga Nguyen
Nga Nguyen
JMJoydeep Mitra
Joydeep Mitra
To accomplish feasible large-scale integration of distributed energy resources (DER) into the existing grid system, microgrid implementation has proven to be the most effective. This paper reviews the vital aspects of DER based microgrid and presents simulations to investigate the impacts of DER sources, electric vehicles (EV), and energy storage system (ESS) on practicable architectures resilient operation. The focus is primarily on the concept and definition of microgrid, comparison of control strategies (primary, secondary and tertiary strategies), energy management strategies, power quality issues associated with DER based microgrid, and state-of-the-art entities such as ESS and EV's applications towards microgrid reliability. Following discussion on the different attributes of DER sources based microgrid, simulations are performed to verify the results of the past works on the effects of solar, wind energy sources, ESS, and EVs on the microgrid frequency response. Additional simulations are conducted to assess the influences of DERs, ESS, EVs and their operational strategies on the microgrid reliability aspects.

25 November 2015 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
NNNga Nguyen
Nga Nguyen
JMJoydeep Mitra
Joydeep Mitra
The integration of renewable energy sources into power systems has gathered significant momentum globally because of its unlimited supply and environmental benefits. Within the portfolio of renewable energy, wind power is expected to have a soaring growth rate in the coming years. Despite its well known benefits, wind power poses several challenges in grid integration. The inherent intermittent and non-dispatchable features of wind power not only inject additional fluctuations to the already variable nature of frequency deviation, they also decrease frequency stability by reducing the inertia and the regulation capability. This paper closely examines these effects as well as the effect on tie-line flows and area control error, which causes a larger and longer frequency deviation in the integrated system. Further, the effect of wind power on frequency regulation capability at different penetration levels is also examined. The analytical and simulation results presented here provide some guidance on determining maximum wind power penetration level given a frequency deviation limit.

1 June 2014 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
SESalem Elsaiah
Salem Elsaiah
MBMohammed Ben-Idris
Mohammed Ben-Idris
JMJoydeep Mitra
Joydeep Mitra
An analytical method for placement and sizing of distributed generation on power distribution systems for loss reduction is introduced. The proposed analytical method is developed based on a new formulation for the power flow problem, which is non‐iterative, direct, and involves no convergence issues even for systems with high R / X branch ratios. Further, this power flow solution is extremely useful whenever fast and repetitive power flow estimations are required. A priority list based on loss sensitivity factors is developed to determine the optimal locations of the candidate distributed generation units. Sensitivity analysis is performed to estimate the optimal size and power factor of the candidate distributed generation units. Various types of distributed generators (DGs) have been dealt with and viable solutions are proposed to reduce total system loss. The proposed method has been tested on 33‐bus and 69‐bus distribution systems, which are extensively used as examples in solving the placement and sizing problem of DGs. Exhaustive power flow routines are also performed to verify the sizes obtained by the analytical method. The test results show that the proposed analytical method could lead to optimal or near‐optimal solution, while requiring lower computational effort.

1 January 1997 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
CSC. Singh
C. Singh
JMJ. Mitra
J. Mitra

26 December 2006 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BMBruce A. Mork
Bruce A. Mork
FGFrancisco Gonzalez
Francisco Gonzalez
DIDmitry Ishchenko
Dmitry Ishchenko
DSDon L. Stuehm
Don L. Stuehm
JMJoydeep Mitra
Joydeep Mitra
A new topologically correct hybrid transformer model is developed for low and midfrequency transient simulations. Power transformers have a conceptually simple design, but behaviors can be very complex. The selection of the most suitable representation for a given behavior depends on the type of transformer to be simulated, the frequency range, and other factors, such as the internal design of the transformer and available parameters or design data. Here, a modular model suitable for frequencies up to 3-5 kHz is developed, utilizing a duality-based lumped-parameter saturable core, matrix descriptions of leakage and capacitive effects, and frequency-dependent coil resistance. Implementation and testing of this model was done for 15-kVA 208Delta-120Y 3-legged and 150-kVA 12,470Y-208Y 5-legged transformers. The basis and development of the model is presented, along with a discussion of necessary parameters and the approaches for obtaining them