Sergi Marcoval

Sergi Marcoval

Auto-generated profile, based on publicly available information

Sergi Marcoval

MiWEndo Solutions, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in IEEE Access
Verified
Journal Article
Open access
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
RSRoberto Sont
Roberto Sont
WDWalid Dghoughi
Walid Dghoughi
SMSergi Marcoval
Sergi Marcoval
JRJordi Romeu
Jordi Romeu
MGMarta Guardiola
Marta Guardiola
A system to integrate microwave imaging with optical colonoscopy is presented. The overarching goal is to improve the prevention and early diagnosis of one of the main health and economic burdens of an increasingly aging population, i.e., colorectal cancer. For a colonoscopy, the gold standard for colorectal cancer diagnosis, 22% of polyps are not detected, and the risk of cancer after a negative colonoscopy can be up to 7.9%. To remedy this, a microwave imaging system able to generate an alarm when a polyp is detected is designed, manufactured and validated with a colon phantom composed of tissue-mimicking oil-gelatin materials reproducing the anatomy and dielectric properties of a human colon with a polyp. The acquisition was performed by a miniaturized ring-shaped switched array of 16 antennas attachable at the tip of a conventional colonoscope. This has been conceived to satisfy endoscopy size restrictions, patient safety and intercompatibility with current clinical practice. A Modified Monofocusing imaging method preceded by a previous frame average subtraction as a calibration technique shows a perfect detection of a 10-mm polyp (100% sensitivity and specificity) in the eight analyzed trajectories. The phantom results demonstrate the feasibility of the system in future preclinical trials.

29 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MGMarta Guardiola
Marta Guardiola
WDWalid Dghoughi
Walid Dghoughi
RSRoberto Sont
Roberto Sont
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
SMSergi Marcoval
Sergi Marcoval
GFGlòria Fernández-Esparrach
Glòria Fernández-Esparrach
This study assesses the efficacy of detecting colorectal cancer precursors or polyps in an ex vivo human colon model with a microwave colonoscopy algorithm. Nowadays, 22% of polyps go undetected with conventional colonoscopy, and the risk of cancer after a negative colonoscopy can be up to 7.9%. We developed a microwave colonoscopy device that consists of a cylindrical ring-shaped switchable microwave antenna array that can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external unit that allows successive measurements of the colon and processes the measurements with a microwave imaging algorithm. An acoustic signal is generated when a polyp is detected. Fifteen ex vivo freshly excised human colons with cancer (n = 12) or polyps (n = 3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%.

28 January 2022 in Gastroenterology Research and Practice
Verified
Journal Article
Open access
PDF file
GFGloria Fernández-Esparrach
Gloria Fernández-Esparrach
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
RSRoberto Sont
Roberto Sont
WDWalid Dghoughi
Walid Dghoughi
SMSergi Marcoval
Sergi Marcoval
MGMarta Guardiola
Marta Guardiola
Introduction. Microwave imaging can obtain 360° anatomical and functional images of the colon representing the existing contrast in dielectric properties between different tissues. Microwaves are safe (nonionizing) and have the potential of reducing the visualization problems of conventional colonoscopy. This study assessed the efficacy of a microwave-based colonoscopy device to detect neoplastic lesions in an ex vivo human colon model. Methods. Fresh surgically excised colorectal specimens containing cancer or polyps were fixed to a 3D positioning system, and the accessory device was introduced horizontally inside the ex vivo colon lumen and moved along it simulating a real colonoscopy exploration. Measurements of the colon were taken every 4 mm with the microwave-based colonoscopy device and processed with a microwave imaging algorithm. Results. 14 ex vivo human colorectal specimens with carcinomas ( ) or adenomas with high grade dysplasia ( ) were examined with a microwave-based device. Using a detection threshold of 2.79 for the dielectric property contrast, all lesions were detected without false positives or false negatives. Conclusions. This study demonstrates the use of a microwave-based device to be used as an accessory of a standard colonoscope to detect neoplastic lesions in surgically excised colorectal specimens.

7 June 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
MGMarta Guardiola
Marta Guardiola
WDWalid Dghoughi
Walid Dghoughi
RSRoberto Sont
Roberto Sont
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
SMSergi Marcoval
Sergi Marcoval
GFGlòria Fernández-Esparrach
Glòria Fernández-Esparrach
This study assesses the efficacy of a microwave colonoscopy algorithm to detect colorectal cancer precursors or polyps in an ex-vivo human colon model. The algorithm works with a device composed of a cylindrical ring-shaped switchable antenna array, which can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external processing unit that generates an acoustic signal when a polyp is detected. Nowadays, 22% of polyps go undetected with conventional colonoscopy and the risk of cancer after a negative colonoscopy can be up to 7.9%. Fifteen ex-vivo freshly excised human colons with cancer (n=12) or polyps (n=3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. Successive measurements of the colon were taken with the microwave-based colonoscopy device and processed with a microwave imaging algorithm. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and finally the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%.