Tomohiko Inui

Tomohiko Inui

Auto-generated profile, based on publicly available information

Tomohiko Inui

Department of Cardiovascular Surgery, Chiba University Hospital , Chiba 286-0041, Japan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2020 in JMIR Cardio
Verified
Journal Article
Open access
TITomohiko Inui
Tomohiko Inui
HKHiroki Kohno
Hiroki Kohno
YKYohei Kawasaki
Yohei Kawasaki
KMKaoru Matsuura
Kaoru Matsuura
HUHideki Ueda
Hideki Ueda
GMGoro Matsumiya
Goro Matsumiya
Background: Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. Objective: This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. Methods: A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. Results: Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). Conclusions: In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.

1 August 2022 in JMIR Formative Research
Verified
Journal Article
Open access
DHDaisuke Hiraoka
Daisuke Hiraoka
TITomohiko Inui
Tomohiko Inui
EKEiryo Kawakami
Eiryo Kawakami
MOMegumi Oya
Megumi Oya
ATAyumu Tsuji
Ayumu Tsuji
GMGoro Matsumiya
Goro Matsumiya
Background: Some attempts have been made to detect atrial fibrillation (AF) with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. Objective: This study is the second part of a 2-phase study aimed at developing a method for immediate detection of paroxysmal AF, using a wearable device with built-in photoplethysmography (PPG). The objective of this study is to develop an algorithm to immediately diagnose AF by an Apple Watch equipped with a PPG sensor that is worn by patients undergoing cardiac surgery and to use machine learning on the pulse data output from the device. Methods: A total of 80 patients who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative AF, using a telemetry-monitored electrocardiogram (ECG) and an Apple Watch. AF was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on the pulse rate data output from the Apple Watch. Results: One of the 80 patients was excluded from the analysis due to redness caused by wearing the Apple Watch. Of 79 patients, 27 (34.2%) developed AF, and 199 events of AF including brief AF were observed. Of them, 18 events of AF lasting longer than 1 hour were observed, and cross-correlation analysis showed that pulse rate measured by Apple Watch was strongly correlated (cross-correlation functions [CCF]: 0.6-0.8) with 8 events and very strongly correlated (CCF>0.8) with 3 events. The diagnostic accuracy by machine learning was 0.9416 (sensitivity 0.909 and specificity 0.838 at the point closest to the top left) for the area under the receiver operating characteristic curve. Conclusions: We were able to safely monitor pulse rate in patients who wore an Apple Watch after cardiac surgery. Although the pulse rate measured by the PPG sensor does not follow the heart rate recorded by telemetry-monitored ECGs in some parts, which may reduce the accuracy of AF diagnosis by machine learning, we have shown the possibility of clinical application of using only the pulse rate collected by the PPG sensor for the early detection of AF.

2 January 2020 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
TITomohiko Inui
Tomohiko Inui
HKHiroki Kohno
Hiroki Kohno
KMKaoru Matsuura
Kaoru Matsuura
HUHideki Ueda
Hideki Ueda
YTYusaku Tamura
Yusaku Tamura
GMGoro Matsumiya
Goro Matsumiya

3 September 2024 in Journal of Surgical Case Reports
Verified
Journal Article
Open access
PDF file
KMKotaro Mukasa
Kotaro Mukasa
HNHironobu Nishiori
Hironobu Nishiori
HIHiroki Ikeuchi
Hiroki Ikeuchi
TITomohiko Inui
Tomohiko Inui
GMGoro Matsumiya
Goro Matsumiya
A 74-year-old male with a history of cardioembolic stroke, chronic atrial fibrillation, and cerebral hemorrhage, who had undergone left atrial appendage closure using the WATCHMAN device 1 year prior, was diagnosed with a 25-mm intra-cardiac mass in the right atrium. The patient underwent the surgical removal of the right atrial mass and the explantation of the WATCHMAN device. The WATCHMAN device was explanted with an external incision at the base of the left atrial appendage, facilitating the removal of the device and the closure of the appendage through direct suturing. The pathological examination confirmed the right atrial mass to be a thrombus. The patient was discharged on postoperative Day 13. From the perspectives of simplicity and radicality, the external approach could be a good option.

25 March 2020 in Annals of Vascular Diseases
Verified
Journal Article
Open access
PDF file
TITomohiko Inui
Tomohiko Inui
KIKeiichi Ishida
Keiichi Ishida
HKHiroki Kohno
Hiroki Kohno
KMKaoru Matsuura
Kaoru Matsuura
HUHideki Ueda
Hideki Ueda
GMGoro Matsumiya
Goro Matsumiya
Pulmonary embolectomy is an effective treatment of acute pulmonary embolism (APE) but not for chronic pulmonary thromboembolism. We described surgical experience of two patients with APE in preexistent unidentified chronic pulmonary thromboembolism. One patient who presented with severe hypoxia but stable hemodynamics underwent successful pulmonary endarterectomy for proximal organized thrombus instead of pulmonary embolectomy. The other patient who required extracorporeal membrane oxygenation for severe hypoxia developed right heart failure because of residual distal organized thrombus after pulmonary embolectomy. Clinical and radiographical presentation of APE in chronic pulmonary thromboembolism mimics APE, and thus, candidates of pulmonary embolectomy should be carefully selected.

2 December 2021 in JMIR Preprints
Verified
Preprint
Open access
DHDaisuke Hiraoka
Daisuke Hiraoka
TITomohiko Inui
Tomohiko Inui
EKEiryo Kawakami
Eiryo Kawakami
MOMegumi Oya
Megumi Oya
ATAyumu Tsuji
Ayumu Tsuji
GMGoro Matsumiya
Goro Matsumiya
BACKGROUND Some attempts have been made to detect atrial fibrillation with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE This study is the second part of a two-phase study aimed at developing a method for immediate detection of paroxysmal atrial fibrillation (AF) using a wearable device with built-in PPG. The objective of this study is to develop an algorithm to immediately diagnose atrial fibrillation by wearing an Apple Watch equipped with a photoplethysmography (PPG) sensor on patients undergoing cardiac surgery and using machine learning of the pulse data output from the device. METHODS A total of 80 subjects who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative atrial fibrillation using telemetry monitored ECG and Apple Watch. Atrial fibrillation was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on pulse rate data output from the Apple Watch. RESULTS One of the 80 patients was excluded from the analysis due to redness of the Apple Watch wearer. 27 (34.2%) of the 79 patients developed AF, and 199 events of AF, including brief AF, were observed. 18 events of AF lasting longer than 1 hour were observed, and Cross-correlation analysis (CCF) showed that pulse rate measured by Apple Watch was strongly correlated (CCF 0.6-0.8) with 8 events and very strongly correlated (CCF >0.8) with 3 events. The diagnostic accuracy by machine learning was 0.7952 (sensitivity 0.6312, specificity 0.8605 at the point closest to the top-left) for the AUC of the ROC curve. CONCLUSIONS We were able to safely monitor pulse rate in patients after cardiac surgery by wearing an Apple Watch. Although the pulse rate from the PPG sensor does not follow the heart rate of the telemetry monitoring ECG in some parts, which may reduce the accuracy of the diagnosis of atrial fibrillation by machine learning, we have shown the possibility of clinical application of early detection of atrial fibrillation using only the pulse rate collected by the PPG sensor. CLINICALTRIAL The use of wristband type continuous pulse measurement device with artificial intelligence for early detection of paroxysmal atrial fibrillation Clinical Research Protocol No. jRCTs032200032 https://jrct.niph.go.jp/latest-detail/jRCTs032200032