Kevin M. Kelly

Kevin M. Kelly

Auto-generated profile, based on publicly available information

Kevin M. Kelly

Allegheny General Hospital, 320 E North Ave, Pittsburgh, PA 15212, United States

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2017 in Epilepsia
Verified
Journal Article
Open access
PDF file
SKShilpa Kadam
Shilpa Kadam
RDRaimondo D'Ambrosio
Raimondo D'Ambrosio
VDVenceslas Duveau
Venceslas Duveau
CRCorinne Roucard
Corinne Roucard
NGNorberto Garcia‐Cairasco
Norberto Garcia‐Cairasco
KKKevin M. Kelly
Kevin M. Kelly
Summary: In vivo electrophysiological recordings are widely used in neuroscience research, and video‐electroencephalography (vEEG) has become a mainstay of preclinical neuroscience research, including studies of epilepsy and cognition. Studies utilizingvEEGtypically involve comparison of measurements obtained from different experimental groups, or from the same experimental group at different times, in which one set of measurements serves as “control” and the others as “test” of the variables of interest. Thus, controls provide mainly a reference measurement for the experimental test. Control rodents represent an undiagnosed population, and cannot be assumed to be “normal” in the sense of being “healthy.” Certain physiologicalEEGpatterns seen in humans are also seen in control rodents. However, interpretation of rodentvEEGstudies relies on documented differences in frequency, morphology, type, location, behavioral state dependence, reactivity, and functional or structural correlates of specificEEGpatterns and features between control and test groups. This paper will focus on the vEEG of standard laboratory rodent strains with the aim of developing a small set of practical guidelines that can assist researchers in the design, reporting, and interpretation of future vEEG studies. To this end, we will: (1) discuss advantages and pitfalls of common vEEG techniques in rodents and propose a set of recommended practices and (2) present EEG patterns and associated behaviors recorded from adult rats of a variety of strains. We will describe the defining features of selected vEEG patterns (brain‐generated or artifactual) and note similarities to vEEG patterns seen in adult humans. We will note similarities to normal variants or pathological human EEG patterns and defer their interpretation to a future report focusing on rodent seizure patterns.

1 May 2019 in Journal of Head Trauma Rehabilitation
Verified
Journal Article
Open access
KKKevin M. Kelly
Kevin M. Kelly
AKAlex Kiderman
Alex Kiderman
SASam Akhavan
Sam Akhavan
MQMatthew R. Quigley
Matthew R. Quigley
ESEdward D. Snell
Edward D. Snell
RARobin C. Ashmore
Robin C. Ashmore
Objective: The purpose of the study was to test the ability of oculomotor, vestibular, and reaction time (OVRT) metrics to serve as a concussion assessment or diagnostic tool for general clinical use. Setting and Participants: Patients with concussion were high school-aged athletes clinically diagnosed in a hospital setting with a sports-related concussion (n = 50). Control subjects were previously recruited male and female high school student athletes from 3 local high schools (n = 170). Design: Video-oculography was used to acquire eye movement metrics during OVRT tasks, combined with other measures. Measures were compared between groups, and a subset was incorporated into linear regression models that could serve as indicators of concussion. Measures: The OVRT test battery included multiple metrics of saccades, smooth pursuit tracking, nystagmoid movements, vestibular function, and reaction time latencies. Results: Some OVRT metrics were significantly different between groups. Linear regression models distinguished control subjects from concussion subjects with high accuracy. Metrics included changes in smooth pursuit tracking, increased reaction time and reduced saccade velocity in a complex motor task, and decreased optokinetic nystagmus (OKN) gain. In addition, optokinetic gain was reduced and more variable in subjects assessed 22 or more days after injury. Conclusion: These results indicate that OVRT tests can be used as a reliable adjunctive tool in the assessment of concussion and that OKN results appear to be associated with a prolonged expression of concussion symptoms.


1 January 2019 in American Journal of Kidney Diseases
Verified
Journal Article
Closed access
VTVictoria Títoff
Victoria Títoff
HMHeather N. Moury
Heather N. Moury
ITIgor B. Títoff
Igor B. Títoff
KKKevin M. Kelly
Kevin M. Kelly

1 March 2018 in Epilepsy Research
Verified
Journal Article
Closed access
KKKevin M. Kelly
Kevin M. Kelly
PJPeter I. Jukkola
Peter I. Jukkola
GYGuo Yin
Guo Yin
EMEric R. Miller
Eric R. Miller
EKElena A. Kharlamov
Elena A. Kharlamov
JAJaroslaw Aronowski
Jaroslaw Aronowski

1 October 2018 in Epilepsy & Behavior
Verified
Journal Article
Closed access
ZSZhuopin Sun
Zhuopin Sun
SLShiying Liu
Shiying Liu
EKElena A. Kharlamov
Elena A. Kharlamov
EMEric R. Miller
Eric R. Miller
KKKevin M. Kelly
Kevin M. Kelly