Atakan Tantekin

Atakan Tantekin

Auto-generated profile, based on publicly available information

Atakan Tantekin

Adana Alparslan Turkes Bilim ve Teknoloji Universitesi

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


1 August 2021 in International Journal of Heat and Fluid Flow
Verified
Journal Article
Closed access
ATAtakan Tantekin
Atakan Tantekin
NON. Filiz Tumen Ozdil
N. Filiz Tumen Ozdil
HAHüseyin Akilli
Hüseyin Akilli
MCMeltem Caliskan
Meltem Caliskan

9 August 2023 in International Journal of Computational Fluid Dynamics
Verified
Journal Article
Closed access
ATAtakan Tantekin
Atakan Tantekin
NON. Filiz Tumen Ozdil
N. Filiz Tumen Ozdil
HAHüseyin Akilli
Hüseyin Akilli

17 October 2022 in Çukurova Üniversitesi Mühendislik Fakültesi Dergisi
Verified
Journal Article
Closed access
PDF file
ATAtakan Tanteki̇n
Atakan Tanteki̇n
NÖNaime Filiz Tümen Özdil
Naime Filiz Tümen Özdil
Increased energy demand and fossil fuel usage of the world has led to the search for new and clean energy production methods. Renewable energy sources are developing and emerging options for energy production methods. Sun is the most accessible and stable renewable energy source. There are several methods to produce energy from the sun. The building-integrated photovoltaic (BIPV) system is a well-known method for generating electricity by using solar cells to transform the energy from the sun into electricity. BIPVs are a new technique to reduce energy consumption from fossil fuels. Passive solar houses mean that the energy demand of the living space is met with the usage of solar energy for the heating and cooling demand of the living space. In this study, an existing house, located in Istanbul, is modeled and covered with photovoltaics with the help of a computer program and the amount of energy produced with the aid of these photovoltaics is presented. The analysis demonstrates that the yearly average amount of daily electricity production is varied between 1.05 kWh as the minimum value and 19.7 kWh as the maximum value for all facades. The yearly average amount of monthly electricity production is varied between 31.8 kWh as the minimum value and 599 kWh as the maximum value for all facades.

15 March 2025 in Karadeniz Fen Bilimleri Dergisi
Verified
Journal Article
Closed access
ATAtakan Tantekin
Atakan Tantekin
The study analyzes energy and exergy in the basic vapor compression refrigeration system. The system consists of four parts as expansion valve, condenser, evaporator and compressor. In each component, energy and exergy balance is employed and the effectiveness of the basic vapor compression refrigeration system is presented. In the study, to evaluate the impact of different refrigerants on system effectiveness, four different gases (R134a, R125, R141b, R423a) at constant dead state temperature (T0 = 25 oC) are analyzed. According to the results, while the COP of R134a is 2.50, the total exergy destruction is 2.31 kW. While the COP of R423a is 0.22, the total exergy destruction is 0.50kW. While the COP of R141b is 0.60, the total exergy destruction is 7.38kW. While the COP of R125 is 0.53, the total exergy destruction is 4.74kW.