Charles E. Seyler

Charles E. Seyler

Auto-generated profile, based on publicly available information

Charles E. Seyler

Laboratory of Plasma Studies, Cornell University , Ithaca, New York 14853, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
CSC. E. Seyler
C. E. Seyler
MMM. R. Martin
M. R. Martin
NHN. D. Hamlin
N. D. Hamlin
The MagLIF (Magnetized Liner Inertial Fusion) experiment at Sandia National Labs is one of the three main approaches to inertial confinement fusion. Radiographic measurements of the imploding liner have shown helical structuring that was not included in MagLIF scaling calculations but that could fundamentally change the viability of the approach. We present the first MagLIF linear dynamics simulations, using extended magnetohydrodynamical (XMHD) as well as standard MHD modeling, that reproduce these helical structures, thus enabling a physical understanding of their origin and development. Specifically, it is found that low-density plasma from the simulated power flow surfaces can compress the axial flux in the region surrounding the liner, leading to a strong layer of axial flux on the liner. The strong axial magnetic field on the liner imposes helical magneto-Rayleigh-Taylor perturbations into the imploding liner. A detailed comparison of XMHD and MHD modeling shows that there are defects in the MHD treatment of low-density plasma dynamics that are remedied by inclusion of the Hall term that is included in our XMHD model. In order to obtain fair agreement between XMHD and MHD, great care must be taken in the implementation of the numerics, especially for MHD. Even with a careful treatment of low-density plasma, MHD exhibits significant shortcomings that emphasize the importance of using XMHD modeling in pulsed-power driven high-energy-density experiments. The present results may explain why past MHD modeling efforts have failed to produce the helical structuring without initially imposing helical perturbations.

8 September 2007 in Journal of Geophysical Research
Verified
Journal Article
Closed access
PDF file
CSC. E. Seyler
C. E. Seyler
KLK. Liu
K. Liu

1 December 2017 in Physics of Plasmas
Verified
Journal Article
Open access
TBT. Byvank
T. Byvank
JBJ. T. Banasek
J. T. Banasek
WPW. M. Potter
W. M. Potter
JGJ. B. Greenly
J. B. Greenly
CSC. E. Seyler
C. E. Seyler
BKB. R. Kusse
B. R. Kusse
We experimentally measure the effects of an applied axial magnetic field (Bz) on laboratory plasma jets and compare the experimental results with numerical simulations using an extended magnetohydrodynamics code. A 1 MA peak current, 100 ns rise time pulse power machine is used to generate the plasma jet. On application of the axial field, we observe on-axis density hollowing and a conical formation of the jet using interferometry, compression of the applied Bz using magnetic B-dot probes, and azimuthal rotation of the jet using Thomson scattering. Experimentally, we find densities ≲5 × 1017 cm−3 on-axis relative to jet densities of ≳3 × 1018 cm−3. For aluminum jets, 6.5 ± 0.5 mm above the foil, we find on-axis compression of the applied 1.0 ± 0.1 T Bz to a total 2.4 ± 0.3 T, while simulations predict a peak compression to a total 3.4 T at the same location. On the aluminum jet boundary, we find ion azimuthal rotation velocities of 15–20 km/s, while simulations predict 14 km/s at the density peak. We discuss possible sources of discrepancy between the experiments and simulations, including surface plasma on B-dot probes, optical fiber spatial resolution, simulation density floors, and 2D vs. 3D simulation effects. This quantitative comparison between experiments and numerical simulations helps elucidate the underlying physics that determines the plasma dynamics of magnetized plasma jets.

2 January 2013 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
PGP.-A. Gourdain
P.-A. Gourdain
CSC. E. Seyler
C. E. Seyler
Using a 1-MA, 100 ns-rise-time pulsed power generator, radial foil configurations can produce strongly collimated plasma jets. The resulting jets have electron densities on the order of 1020  cm−3, temperatures above 50 eV and plasma velocities on the order of 100  km/s, giving Reynolds numbers of the order of 103, magnetic Reynolds and Péclet numbers on the order of 1. While Hall physics does not dominate jet dynamics due to the large particle density and flow inside, it strongly impacts flows in the jet periphery where plasma density is low. As a result, Hall physics affects indirectly the geometrical shape of the jet and its density profile. The comparison between experiments and numerical simulations demonstrates that the Hall term enhances the jet density when the plasma current flows away from the jet compared to the case where the plasma current flows towards it.

11 August 2005 in Journal of Geophysical Research
Verified
Journal Article
Closed access
PDF file
EKE. M. Klatt
E. M. Klatt
PKP. M. Kintner
P. M. Kintner
CSC. E. Seyler
C. E. Seyler
KLK. Liu
K. Liu
EME. A. MacDonald
E. A. MacDonald
KLK. A. Lynch
K. A. Lynch

1 October 2017 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
PGP.-A. Gourdain
P.-A. Gourdain
MAM. B. Adams
M. B. Adams
JDJ. R. Davies
J. R. Davies
CSC. E. Seyler
C. E. Seyler
MagLIF is a fusion concept using a Z-pinch implosion to reach thermonuclear fusion. In current experiments, the implosion is driven by the Z-machine using 19 MA of electrical current with a rise time of 100 ns. MagLIF requires an initial axial magnetic field of 30 T to reduce heat losses to the liner wall during compression and to confine alpha particles during fusion burn. This field is generated well before the current ramp starts and needs to penetrate the transmission lines of the pulsed-power generator, as well as the liner itself. Consequently, the axial field rise time must exceed hundreds of microseconds. Any coil capable of being submitted to such a field for that length of time is inevitably bulky. The space required to fit the coil near the liner, increases the inductance of the load. In turn, the total current delivered to the load decreases since the voltage is limited by driver design. Yet, the large amount of current provided by the Z-machine can be used to produce the required 30 T field by tilting the return current posts surrounding the liner, eliminating the need for a separate coil. However, the problem now is the field penetration time, across the liner wall. This paper discusses why skin effect arguments do not hold in the presence of resistivity gradients. Numerical simulations show that fields larger than 30 T can diffuse across the liner wall in less than 60 ns, demonstrating that external coils can be replaced by return current posts with optimal helicity.